Size Exclusion Chromatography Analysis of Antibody Drug Conjugates

Technical Reference Summary

Covered Models & Document Scope

Application note covering the Agilent 1260 Infinity II Bio-inert LC system configuration (Bio-inert Pump G5654A, Bio-inert Multisampler G5668A with sample cooler option #100, Multicolumn Thermostat G7116A with bio-inert heat exchanger option #019, Diode Array Detector WR G7115A with bio-inert flow cell option #028) used with AdvanceBio SEC 300 Å, 7.8 × 300 mm, 2.7 µm (p/n PL1180-5301) and Bio SEC-3, 300 Å, 7.8 × 300 mm, 3 µm (p/n 5190-2511) columns; software OpenLAB CDS Version 2.1.

Technical Data

Parameter Value Condition
Column dimensions 7.8 × 300 mm p.2 ↗ AdvanceBio SEC 300 Å, 2.7 µm (p/n PL1180-5301)
Column dimensions 7.8 × 300 mm p.2 ↗ Bio SEC-3, 300 Å, 3 µm (p/n 5190-2511)
Column particle size 2.7 µm p.2 ↗ AdvanceBio SEC 300 Å (p/n PL1180-5301)
Column pore size 300 Å p.2 ↗ AdvanceBio SEC (p/n PL1180-5301)
Column pore size 300 Å p.2 ↗ Bio SEC-3 (p/n 5190-2511)
Injection volume 10 µL p.2 ↗
Needle wash mode Standard Wash p.2 ↗
Salt concentration tolerance 2 M NaCl p.2 ↗ Bio-inert flowpath
Urea concentration tolerance up to 8 M urea p.2 ↗ Bio-inert flowpath
NaOH concentration tolerance 0.5 M NaOH p.2 ↗ Bio-inert flowpath
HCl concentration tolerance 0.5 M HCl p.2 ↗ Bio-inert flowpath
Software version 2.1 p.2 ↗ OpenLAB CDS

Operating Limits

  • Maximum salt concentration (NaCl): 2 M p.2 ↗
  • Maximum urea concentration: 8 M p.2 ↗
  • Maximum NaOH concentration: 0.5 M p.2 ↗
  • Maximum HCl concentration: 0.5 M p.2 ↗

Type Code Decoder

Position Token Meaning
field 1 p.2 ↗ G5654A Agilent 1260 Infinity II Bio-inert Pump
field 2 p.2 ↗ G5668A Agilent 1260 Infinity II Bio-inert Multisampler
field 3 p.2 ↗ G7116A Agilent 1260 Infinity II Multicolumn Thermostat
field 4 p.2 ↗ G7115A Agilent 1260 Infinity II Diode Array Detector WR

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
Agilent 1260 Infinity II Bio-inert Pump (G5654A) p.2 ↗ G5654A System module
Agilent 1260 Infinity II Bio-inert Multisampler (G5668A) with sample cooler (option #100) p.2 ↗ G5668A #100 with sample cooler option System module
Agilent 1260 Infinity II Multicolumn Thermostat (G7116A) with bio-inert heat exchanger (option #019) p.2 ↗ G7116A #019 with bio-inert heat exchanger option System module
Agilent 1260 Infinity II Diode Array Detector WR (G7115A) with bio-inert flow cell (option #028) p.2 ↗ G7115A #028 with bio-inert flow cell option System module
Agilent AdvanceBio SEC 300 Å, 7.8 × 300 mm, 2.7 µm p.2 ↗ PL1180-5301 SEC column
Agilent Bio SEC-3, 300 Å, 7.8 × 300 mm, 3 µm p.2 ↗ 5190-2511 SEC column