Induztr
Engineering Digest Document Viewer Related Models

Agilent 9500 Triple Quadrupole ICP-MS Brochure

Contents

  1. Overview pp. 1-3
    Introduction to the 9500 ICP-QQQ and its key benefits
  2. Overview pp. 4-5
    Built for confidence and simplicity in routine analysis
  3. Quality pp. 6-7
    Performance data and results achievable by any lab
  4. Overview pp. 8-9
    Effortless operation and focus on core lab work
  5. Overview p. 9
    Summary of the Agilent 9500 ICP-QQQ advantages
  6. p. 6 table, 25 rows
  7. p. 4 table, 3 rows

Table 1. MSA calibration curves for the Ti digestion solution and procedural blank were used to determine 3σ DLs of blank samples (n = 5), BECs, and impurity metal concentrations in the original Ti sample.

AnalyteQ1Q2TuneNo Ti Matrix DL (ppt)No Ti Matrix BEC (ppt)Ti Matrix DL (ppt)Ti Matrix BEC (ppt)Impurity Metal Conc in Original Ti Powder (ppb)
B1111H21.922.836.3212.749.4
Na2323NH3 + H22.033.257.5291.4441
Mg2424NH3 + H20.66< DL42.816008000
Al2727NH3 + H20.52< DL5.1457.1286
K3939NH3 + H22.304.332.346.269.7
Ca4040H20.621.521.3648.9237
V5151NH3 + H20.23< DL2.393.4417.2
Cr5252NH3 + H20.651.337.64100493
Mn5555NH3 + H20.250.293.0738.2190
Fe5656NH3 + H22.342.64265424021200
Co5959NH3 + H2ND< DL0.670.844.2
Ni6060NH3 + H20.84< DL18.690450
Cu6397NH3 + H22.352.48.22110538
Zn6868NH3 + H21.4858.9418.366.5
Y8989H20.03< DL0.09< DL< DL
Zr9090H20.09< DL0.221.246.2
Nb9393H20.06< DL0.160.572.8
Mo9595H2ND< DL2.303.7618.8
Ru101101H2ND< DL0.17< DL< DL
Pd105105NH3 + H20.14< DL0.11< DL< DL
Sn118118H20.24< DL0.803.3716.9
Hf178178H2ND< DL0.09< DL< DL
Ta181181H20.02< DL0.271.196.0
W182182H20.06< DL0.140.522.6
Bi209209H20.05< DL0.550.904.5

DL — detection limit; BEC — background equivalent concentration; ND — not detected; < DL — below detection limit.

Instrument dimensions comparison

950079008900
W1060 mm730 mm1060 mm
D600 mm600 mm600 mm
H530 mm595 mm595 mm

65 mm/11% shorter

Engineering Facts

12 facts · every claim linked to a page
Performance

The Dual-Cell System with Advanced Helium Mode and Air mode provides superior interference removal for complex matrices.

Interference removal capability is the primary selection criterion for trace analysis in complex matrices.

Source
“The Dual-Cell System (DCS) with Advanced Helium Mode (AHM) and Air mode provides superior interference removal”
Operation

AHM replaces multiple gas/tune modes with one mode, cutting acquisition time by more than 33% for routine analysis.

Fewer tune modes means simpler operation and higher sample throughput.

Source
“AHM eliminates the need for multiple gas modes and removes the wait times of method switching, typically >33% reduction in acquisition time for routine analysis.”
Safety

Air mode uses ambient air, so no O2 cylinders or gas cabinet infrastructure are required.

Avoids oxygen gas supply, gas cabinet, and associated safety approvals in the lab.

Source
“Air mode uses ambient air, eliminating O2 cylinders and safety concerns.”
Installation

The instrument connects directly to accessories with no rear connections or vents, easing installation and startup.

Simplifies bench layout and installation planning for peripherals.

Source
“Flexible setup with direct connection from instrument to accessories (autosampler, autodilutor, and chiller)”
Installation

The 9500 has a smaller footprint than the 8900, being 65 mm/11% shorter.

Footprint affects lab space planning and bench allocation.

Source
“65 mm/11% shorter”
Maintenance

A cell gas clean sensor notifies when replacement is due, supporting planned maintenance.

Predictive maintenance notification reduces unplanned downtime.

Source
“Cell gas clean sensor to notify when replacement is due”
Operation

Power consumption is reduced 20% and exhaust flow 50%, lowering running costs and facility requirements.

Lower power and exhaust demands affect facility services and operating cost.

Source
“20% reduction in power consumption and 50% reduction in exhaust flow”
Performance

AHM gives about 20x higher sensitivity for low-mass elements and about 2x for mid-to-high masses versus conventional He mode.

Sensitivity gain determines detection limits for low-mass analytes.

Source
“AHM provides ~20× higher sensitivity for low-mass elements such as Li, Be and B, and ~2× for mid-to-high masses.”
Performance

Air mode achieves low BECs for P, S, As, and Se using oxygen from ambient air for mass-shift reactions.

Enables difficult elements without an added oxygen gas supply.

Source
“Air mode achieves low BECs for P, S, As, and Se which were previously only available to labs with an additional oxygen reaction gas supply.”
Performance

An optional m-lens enables sub-ppt impurity analysis in high-purity titanium with high-matrix-tolerant plasma.

Option selection depends on high-matrix, high-purity material applications.

Source
“With an optional m-lens, analysts can confidently analyze Ti matrix samples and verify material purity over extended measurement periods.”
Operation

Direct high-salinity seawater analysis is stable across 130+ analyses using on-line reverse dilution with AVS MS.

Confirms long-run stability for high-salinity samples with the right autosampler setup.

Source
“stability is maintained across 130+ analyses (EPA 6020)”
Operation

The 9500 includes UHMI aerosol dilution and an integrated grounded mixing block for on-line internal standard addition as standard.

Standard productivity tools reduce need for manual dilution and extra hardware.

Source
“The Agilent 9500 includes UHMI aerosol dilution to handle high matrix samples directly, integrated grounded mixing block for the on-line addition of internal standard”