Contents

  1. Overview pp. 1-2
    Introduces natural gas analysis goals and analyzer benefits
  2. Config pp. 3-4
    Describes fast GC and gasifier configurations
  3. Spec pp. 5-6
    Lists analyzer capabilities and industry standards compliance
  4. Config p. 7
    Options to complete the GC system
  5. Services p. 8
    Flexible service and support options
  6. p. 9
    Adding new technologies to the lab
  7. p. 5 table, 10 rows

Agilent natural gas analyzers capabilities

AnalyzerExtended NGASingle-channel NGADual-channel NGASour gas NGASour gas NGANGA ANGA A ExtendedNGA BNGA B Extended
Option Number#610#611#612#613#615#120#121#122#123
Valves33433NANANANA
DetectorsTCD/FIDTCDTCD/TCDTCDTCD/TCD/FID2x μTCD3x μTCD2x μTCD3x μTCD
Columns4 (capillary and packed)4 (packed)6 (packed)4 (packed, corrosion-resistant plumbing)6 (packed)2 (micropacked and WCOT)3 (micropacked, PLOT, and WCOT)2 (PLOT and WCOT)3 (PLOT and WCOT)
Analysis Time20 minutes20 minutes20 minutes30 minutes18 minutes6 minutes2 minutes6 minutes2 minutes up to C7, 6 minutes up to C9
Hydrocarbon RangeC1-C12C1-C5, C6+ as backflushC1-C5, C6+ as backflushC1-C5, C6+ as backflushC1-C14C1-C9C1-C10C1-C9C1-C9
Permanent GasesO2, N2, CO, CO2O2, N2, CO, CO2H2, He, O2, N2, CO, CO2O2, N2, CO, CO2H2, He, N2, COAir, CH4, CO2Air, CH4, CO2Air, CH4, CO2H2, He, Ne, N2, CO, O2
Minimum Detection Level (Hydrocarbons)50 ppm on TCD, 10 ppm C3-C12 on FID0.01mol %0.01mol %0.01mol % 500 ppm for H2S50 ppm C1-C5, 10 ppm C5-C610 ppm C1-C2, 1 ppm C3-C910 ppm C1-C2, 1 ppm C3-C92 ppm C1-C2, 1 ppm C3-C920 ppm C1 2 ppm C2 1 ppm C3-C9
Minimum Detection Level (Permanent Gases)50 ppm0.01mol %0.01mol %0.01mol %50 ppm C1-C5, 10 ppm C5-C610 ppm CO210 ppm CO22 ppm CO2, H2S2 ppm H2, He 20 ppm Ne, O2, N2, CO, CH4 1 ppm C3-C9
Configured PerGPA 2286ASTM D1945, GPA 2261ASTM D1945, GPA 2261ASTM D1945, GPA 2261GPA 2286NANANANA

Таблица транспонирована: колонки — варианты анализаторов (Option Number #610–#123), строки — характеристики.

Engineering Facts

13 facts · every claim linked to a page
Selection

The 8890 NGA can be configured with one or two channels and conforms to ASTM D1945, GPA 2261, and GPA 2286, so method compliance must drive channel selection.

Determines whether the analyzer meets the required standard method for the lab's natural gas scope.

Source
“is configured for one or two channels and conforms to ASTM D1945, GPA 2261, and GPA 2286 methods.”
Selection

A second TCD channel is needed when hydrogen detection and linearity matter.

Guides choice between single- and dual-channel configurations based on required permanent gas coverage.

Source
“A second thermal conductivity detector (TCD) channel improves hydrogen detection and linearity.”
Selection

An optional FID is required for low-level hydrocarbon analysis.

Dictates detector configuration when trace hydrocarbon sensitivity is a requirement.

Source
“Optional flame ionization detector (FID) enables low-level hydrocarbon analysis.”
Selection

The 990 Micro GC PRO is intended for online process environments with onboard data handling and standard communication protocols.

Determines suitability for automated process/online installation and integration with plant systems.

Source
“Meet industry standards with confidence through various communication protocols, such as”
Installation

The GC gasifier accessory is required to safely introduce liquefied gas samples into the GC.

Must be specified and installed when the sample is liquefied gas rather than already gaseous.

Source
“The Agilent GC gasifier accessory safely controls the transition of”
Operation

The gasifier delivers samples at constant flow and pressure, which is essential for repeatable liquefied gas analysis.

Confirms the accessory provides the stable sample conditions needed for reliable quantitation.

Source
“Samples are delivered to the GC system under constant”
Maintenance

The microchannel-based EPC design protects against particulates, water, and oils, improving reliability and longevity.

Informs gas supply cleanliness requirements and expected maintenance profile.

Source
“this design protects against gas contaminants—such as particulates, water, and oils—”
Operation

Remote access allows leak checks, column backflush, and run control without being at the instrument.

Supports decisions on network access and remote operation of the analyzer.

Source
“view setup information, troubleshoot”
Installation

Factory checkout is duplicated onsite with a checkout sample by a factory-trained support engineer at installation.

Defines the installation/commissioning step and resources needed on site.

Source
“Duplicate factory checkout with checkout sample onsite”
Operation

Reporting units depend on region: Btu (FPS) for GPA/ASTM in the US and ISO 6976 / GB/T 11062 metric calculations for EU and China.

Determines the reporting configuration and calculation standard to set up for the site's jurisdiction.

Source
“are used for reporting natural gas composition and physical property calculations according to ISO 6976 for EU and GB/T 11062 for China.”
Maintenance

Gas Clean filters must be replaced at absorption capacity to prevent column damage, sensitivity loss, and downtime.

Establishes a consumable replacement practice that protects columns and hardware.

Source
“Replacing the filters when they have reached absorption”
Maintenance

Genuine replacement parts are covered by a 90-day warranty from shipment plus the service agreement.

Affects spare-parts sourcing decisions and warranty coverage planning.

Source
“every genuine replacement part is covered by a 90-day warranty from the date of shipment”
Performance

The Inert Flow Path reduces analyte adsorption, lowering detection limits for trace-level analysis.

Justifies specifying an inert flow path when trace sulfur or hydrocarbon analysis is required.

Source
“The Agilent Inert Flow Path can decrease analyte adsorption for lower limits of detection”