Induztr
Engineering Digest Document Viewer Related Models

UHV and Leak Detection Solutions Catalog

Contents

  1. Overview pp. 1-2
    Introduction to UHV and leak detection solutions
  2. Overview pp. 3-5
    Solutions for particle and vacuum applications
  3. Ordering p. 6
    Spare parts and accessories information
  4. Config p. 7
    Essential UHV product configurations
  5. Config p. 8
    Turbo pumping system options
  6. Spec p. 9
    Vacuum measurement instruments and specifications
  7. Services p. 10
    Customer support services information
  8. pp. 11-12
    Did you know facts and educational resources
  9. p. 13
    Contact details and getting in touch

Engineering Facts

12 facts · every claim linked to a page
Performance

Ion and turbomolecular pumps reach pressures below 10^-9 mbar with minimal fluctuations, which is essential for qubit coherence in quantum experiments.

Defines the achievable base pressure and noise/vibration constraints when selecting pumps for quantum coherence-sensitive setups.

Source
“Achieve pressures below 10–9 mbar with minimal fluctuations, eliminating vibrations and electromagnetic interference that affect qubit coherence”
Performance

Ion and turbomolecular pumps can reach down to 10^-12 mbar with minimal particle emissions, which is required for proper particle beam operation in accelerators.

Sets the UHV pressure target and particle-emission constraint for accelerator beam-line vacuum design.

Source
“Achieve pressures down to 10–12 mbar with minimal particle emissions, ensuring proper particle beam operation”
Selection

Particle accelerator vacuum systems must operate between 10^-9 and 10^-12 mbar while minimizing vibrations and thermal disturbances in tight spaces.

Gives the required pressure window and environmental constraints for selecting UHV components in accelerator facilities.

Source
“Stable, contamination-free environments, with system pressures between 10–9 and 10–12 mbar”
Selection

Ion pumps with NEG provide pressures down to 10^-11 mbar with zero vibrations, avoiding optical misalignment and thermal disturbances in cryogenic precision systems.

Justifies choosing NEG ion pumps where vibration-free, low-pressure operation is critical for sensitive optics and cryogenics.

Source
“Provide pressures down to 10–11 mbar with zero vibrations, eliminating risks of optical misalignment, signal interference, and thermal disturbances in cryogenic and precision measurement systems”
Selection

Scroll pumps are oil-free and low-vibration, preventing hydrocarbon contamination in long-duration experiments.

Supports selecting dry scroll pumps to avoid hydrocarbon backstreaming that would degrade detector sensitivity.

Source
“Oil-free, low-vibration pumps prevent hydrocarbon contamination, ensuring stability and reliability for long-lasting experiments”
Maintenance

Dry scroll pumps require only 20 to 30 minutes of DIY maintenance every 2 to 3 years, which simplifies long-term upkeep.

Informs maintenance planning and total cost of ownership when choosing scroll pumps.

Source
“Only 20 to 30 minutes DIY maintenance needed every 2 to 3 years”
Performance

Turbo pumping systems achieve low base pressure down to 1x10^-9 mbar with compact, portable, one-switch operation.

Specifies the achievable base pressure for modular turbo pumping systems when selecting a turnkey UHV solution.

Source
“Low base pressure, down to 1x10-9 mbar”
Selection

Vacuum gauges must provide accurate readings from atmosphere to extreme-high vacuum of 1x10^-12 mbar for experiments, detectors, and accelerators.

Defines the required measurement range when selecting gauge tubes and controllers for UHV systems.

Source
“Accurate pressure readings from atmosphere to extreme-high vacuum (1x10-12 mbar), critical for experiments, detectors, and accelerators”
Operation

Leak detectors enable quick identification and isolation of leaks, minimizing downtime in complex setups such as accelerators or space telescopes.

Explains the operational role of helium leak detection in maintaining uptime for large or inaccessible vacuum systems.

Source
“Quick identification and isolation of leaks minimize downtime and optimize system performance in complex setups like accelerators or space telescopes”
Maintenance

Genuine Agilent spare parts and consumables are specifically designed and tested for UHV to minimize contamination risk and experiment failure.

Justifies using authentic parts rather than third-party substitutes to preserve UHV cleanliness and reliability.

Source
“Genuine Agilent spare parts, consumables, and hardware are specifically designed and tested to meet the stringent requirements of UHV environments, minimizing the risk of contamination and experiment failure.”
Operation

The advance exchange service provides factory-refurbished replacement products from stock to get systems back up in days rather than weeks.

Informs service-contract selection for minimizing downtime on turbo pumps, scroll pumps, and ion pump controllers.

Source
“Get back up and running in days—not weeks.”
Selection

Scroll pumps optimize performance based on vapor load and provide complete isolation of pumped gases from the external environment.

Guides pump sizing and selection when the process has variable vapor loads that affect achievable performance.

Source
“Optimize pump performance based on the vapor load”