Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH1690 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 690: side channel blower with IE3-motors, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09 (E225239). Covers type 2BH1690 with several voltage/frequency variants (AK11, AK21, AK16, AK26, AQ13, AQ23, AQ17, AQ27, AQ16, AQ26) and alternate-voltage motor options (Z=K1, Q3, Q5, Q7).

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BH1690-0AK11, 50 Hz, Δ
Rated current 9,9 A p.2 ↗ 2BH1690-0AK11, 50 Hz, Δ
Power 2,50 kW p.2 ↗ 2BH1690-0AK11, 50 Hz
Max. differential pressure, vacuum -200 mbar p.2 ↗ 2BH1690-0AK11, 50 Hz
Max. differential pressure, pressure 170 mbar p.2 ↗ 2BH1690-0AK11, 50 Hz
Sound pressure level 64 dB(A) p.2 ↗ 2BH1690-0AK11, 50 Hz
Weight approx. 34 kg p.2 ↗ 2BH1690-0AK11, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1690-0AK11, 50 Hz
Rated voltage 190-210 ΥΥ / 380-420 Υ V p.2 ↗ 2BH1690-0AK11, 60 Hz
Rated current 12,0 ΥΥ / 6,0 Υ A p.2 ↗ 2BH1690-0AK11, 60 Hz
Power 3,00 kW p.2 ↗ 2BH1690-0AK11, 60 Hz
Max. differential pressure, vacuum -190 mbar p.2 ↗ 2BH1690-0AK11, 60 Hz
Max. differential pressure, pressure 170 mbar p.2 ↗ 2BH1690-0AK11, 60 Hz
Sound pressure level 70 dB(A) p.2 ↗ 2BH1690-0AK11, 60 Hz
Rated voltage 190-210 V p.2 ↗ 2BH1690-0AK21, 50 Hz, Δ
Rated current 13,3 A p.2 ↗ 2BH1690-0AK21, 50 Hz, Δ
Power 3,45 kW p.2 ↗ 2BH1690-0AK21, 50 Hz
Max. differential pressure, vacuum -200 mbar p.2 ↗ 2BH1690-0AK21, 50 Hz
Max. differential pressure, pressure 250 mbar p.2 ↗ 2BH1690-0AK21, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1690-0AK21, 50 Hz
Weight approx. 38 kg p.2 ↗ 2BH1690-0AK21, 50 Hz
Rated voltage 190-210 ΥΥ / 380-420 Υ V p.2 ↗ 2BH1690-0AK21, 60 Hz
Rated current 15,2 ΥΥ / 7,6 Υ A p.2 ↗ 2BH1690-0AK21, 60 Hz
Power 4,0 kW p.2 ↗ 2BH1690-0AK21, 60 Hz
Max. differential pressure, vacuum -240 mbar p.2 ↗ 2BH1690-0AK21, 60 Hz

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1690 Type / size designation (side channel blower 2BH1, size 690)
field 1 p.2 ↗ 0 Series/variant field
field 2 p.2 ↗ A Motor/voltage variant family (A = standard IE3 motor)
field 3 p.2 ↗ K / Q Voltage/motor variant letter (K = 190-210 V, Q = 500/575 V or 380-725 V variants)
field 4 p.2 ↗ 1 / 2 Performance size within type (1 = 2,50/3,00 kW, 2 = 3,45/4,0 kW)
field 5 p.2 ↗ 1 / 6 / 3 / 7 Voltage/frequency variant code (e.g. 1 = 190-210 V, 6 = 220-240/380-420 V, 3 = 500/575 V, 7 = 380-725 V)
Z= field p.2 ↗ K1 / Q3 / Q5 / Q7 Motor for alternate voltages option (Z=K1, Q3, Q5, Q7)

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1690-0AK11 p.2 ↗ 2BH1690-0AK11 50/60 Hz, 190-210 V / 380-420 V IE3, 2,50/3,00 kW
2BH1690-0AK21 p.2 ↗ 2BH1690-0AK21 50/60 Hz, 190-210 V / 380-420 V IE3, 3,45/4,0 kW
2BH1690-0AK16 p.2 ↗ 2BH1690-0AK16 50/60 Hz, 220-240 V / 380-480 V IE3, 2,50/3,00 kW
2BH1690-0AK26 p.2 ↗ 2BH1690-0AK26 50/60 Hz, 220-240 V / 380-480 V IE3, 3,45/4,0 kW
2BH1690-0AQ13 p.2 ↗ 2BH1690-0AQ13 50/60 Hz, 500/575 V IE3, 2,50/3,00 kW
2BH1690-0AQ23 p.2 ↗ 2BH1690-0AQ23 50/60 Hz, 500/575 V IE3, 3,45/4,00 kW
2BH1690-0AQ17 p.2 ↗ 2BH1690-0AQ17 50/60 Hz, 380-420/660-725 V IE3, 2,90/3,0 kW
2BH1690-0AQ27 p.2 ↗ 2BH1690-0AQ27 50/60 Hz, 380-420/660-725 V IE3, 3,45/4,0 kW
2BH1690-0AQ16 p.2 ↗ 2BH1690-0AQ16 50/60 Hz, 220-240/380-420 V IE3, 2,50/3,00 kW
2BH1690-0AQ26 p.2 ↗ 2BH1690-0AQ26 50/60 Hz, 220-240/380-420 V IE3, 3,45/4,0 kW

Related models