Technical Data Sheet — L-BV7 2BV7061 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BV7 061, edition 09/2013: L-BV7 series liquid ring vacuum pump with ejector, model 2BV7 061; standard motors for 50 and 60 Hz input voltage ranges, protection category IP55, approbated for UL and CSA.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Ultimate inlet pressure | 33 mbar abs. p.1 ↗ | 2BV7 061, 97 % vacuum |
| Cavitation-free operation minimum inlet pressure | 80 mbar abs. p.1 ↗ | 2BV7 061, built-in cavitation protection |
| Protection rating | IP55 p.1 ↗ | standard motor |
| Mains frequency | 50 / 60 Hz p.1 ↗ | standard motor input voltage ranges |
| Intake temperature for characteristic curves | 20 °C p.1 ↗ | 100 % saturated air |
| Operating liquid temperature for characteristic curves | 15 °C p.1 ↗ | water as operating liquid, suction pressure 1013 mbar abs. |
| Characteristic curve tolerance | ± 10 % p.1 ↗ |
Operating Limits
- Minimum inlet pressure (ultimate vacuum): 33 mbar abs. p.1 ↗
- Minimum inlet pressure for cavitation-free operation: 80 mbar abs. p.1 ↗
- Protection class: IP55 p.1 ↗