Operating Instructions — VLR 1000 HV (BA 1880-HR, ed. 1.1 14.06.2021, HR)
Technical Reference Summary
Covered Models & Document Scope
This document (BA 1880-HR, Edition 1.1, 14.06.2021) covers the VLR 1000 HV+ central vacuum system, part of the C-Series claw-type vacuum pump family. The system comprises a C-VLR 1000 VSD vacuum pump with frequency inverter and setpoint pressure control, a control unit and control box. The type code C-VLR designates the vacuum pump; the suffix XD designates a vacuum pump with increased water-vapour tolerance. The nameplate example is C-VLR 1000 (29), ID 102781F001, with 25/50 Hz data: 200/200 mbar(abs.), 475/950 m3/h, 1497/2945 1/min, 9.25/18.50 kW.
Section-by-Section Technical Breakdown
Describes the construction of the central vacuum system and identifies its main components: vacuum connection, discharge connection, cooling-air inlet and outlet, oil fill point, oil sight glasses, oil drain points, nameplate, direction-of-rotation arrow, drive motor, hot surfaces >70 °C, condensate drain and discharge silencer. The control box contains the emergency stop button, cable entry, main switch, activation switch and touch screen (HMI). The nameplate carries type/size, year of manufacture, serial number, data-matrix code, article number, motor power, pumping speed, ultimate pressure, frequency range, speed range and operating mode.
- Main pump connections: A vacuum connection, B discharge connection, E cooling-air inlet, F cooling-air outlet.
- Oil system: H oil fill point, I/I1 oil sight glasses, K/K1 oil drain points, M oil recommendation label.
- Hot surfaces >70 °C are marked (Q); direction of rotation arrow (O) is provided.
- Condensate drain X and discharge silencer Z are fitted.
- Control box: 1 emergency stop button, 2 cable entry, 3 main switch, 4 activation switch, 5 touch screen (HMI).
- System components: 1 absolute pressure sensor, 2 solenoid valve (depending on pump), 3 frequency inverter with parameter set, 4 control box, 5 emergency stop button, 6 touch screen (HMI), 7 VLR 1000 vacuum pump, 8 control valve, 9 suction flange.
- Nameplate example C-VLR 1000 (29), ID 102781F001: 25/50 Hz, 200/200 mbar(abs.), 475/950 m3/h, 1497/2945 1/min, 9.25/18.50 kW.
The control unit regulates the vacuum pump to a set target pressure. When demand is low and the target pressure is reached, drive speed is reduced to minimum speed; if this condition (minimum speed, pressure below target) persists for a certain time, the drive is switched off while the control unit remains active. When the target pressure is exceeded, the drive restarts. The electrical control box contains the system control that enables regulation and control of the vacuum pump.
- Control unit maintains an adjustable target pressure by varying pump speed.
- At low delivery volume and reached target pressure, speed drops to minimum.
- If minimum speed and pressure below target persist for a set time, the drive stops but the control unit stays active.
- Drive restarts when target pressure is exceeded.
- Control box contains the dedicated system control for regulation and control of the vacuum pump.
Claw vacuum pumps are suitable for evacuating closed systems or for producing a permanent vacuum in the suction pressure range 200–700 mbar (abs.). Maximum pumping speed with free suction is 950 m3/h at 50 Hz. Maximum permissible back pressure on the discharge side is +50 mbar. Increased switching frequency (regular intervals of about 10 times per hour) or elevated ambient and suction temperatures may exceed the motor winding and bearing temperature limits, so such conditions must be checked with the manufacturer. Outdoor installation requires protection from environmental influences (e.g. a protective roof).
- Suction pressure range: 200–700 mbar (abs.).
- Maximum pumping speed with free suction: 950 m3/h at 50 Hz.
- Maximum permissible back pressure on discharge side: +50 mbar.
- Pumping-speed vs. suction-pressure curve is given in technical data sheet D 1880.
- Switching frequency of about 10 times per hour or elevated ambient/suction temperatures may exceed motor winding and bearing limits — consult manufacturer.
- Outdoor installation must be protected from the environment, e.g. by a protective roof.
Covers preparation for installation, mechanical installation and connection of the piping. The manual warns of explosion hazard and of material damage from improper installation, and of material damage from contaminated suction air. Elastic vibration-damping elements are recommended for mounting. Piping must not impose excessive forces on the connections, and a restricted or closed discharge opening presents an injury hazard.
- Observe explosion-hazard and material-damage warnings during installation preparation.
- Elastic vibration-damping elements are recommended for mounting the unit.
- Contaminated suction air can cause material damage.
- Piping must not transmit excessive forces to the pump connections.
- A restricted or closed discharge opening creates an injury hazard.
Before commissioning, the lubricating oil level must be checked at the oil sight glass (Fig. 2/I, I1) and topped up if necessary. Oil for gears and bearings is filled at the oil fill point (Fig. 2/H) up to the middle of the sight glass. Oil change and suitable oil types are given in Chapter 7.4.2.
- Check oil level at sight glass Fig. 2/I, I1.
- Fill oil at oil fill point Fig. 2/H up to the middle of the sight glass.
- Close the oil fill point after filling.
- Oil change and suitable oil types: see Chapter 7.4.2, page 37.
The electrical installation must be carried out only by a qualified electrician in accordance with EN 60204. The operator must provide a main switch, all metal housing parts must be earthed, earthing must be performed according to the wiring diagram and its function checked, and supply lines must be protected against overcurrent and overvoltage, e.g. by installing a circuit breaker. The frequency inverter instructions must also be observed. No neutral conductor is required for connecting the frequency inverter.
- Electrical installation only by a qualified electrician according to EN 60204.
- Operator must provide the main switch.
- Earth all metal housing parts; earth according to the wiring diagram and verify function.
- Protect supply lines against overcurrent and overvoltage, e.g. with a circuit breaker.
- Observe the frequency inverter operating instructions.
- No neutral conductor is required for the frequency inverter connection.
- Further details in the enclosed circuit diagrams and the frequency inverter instructions.
Table 3 defines maintenance intervals by operating hours. Monthly tasks include checking cable-entry and connection-box openings for leaks, cleaning ventilation openings and motor cooling fins, checking the discharge-air connection for contamination, checking oil level and cleaning the vacuum pump. Contamination-dependent tasks include cleaning the non-return valve and the filter with strainer (at least monthly). Condensate must be drained from the silencer depending on contamination, at least monthly. After 3,000 operating hours or at latest 6 months, piping and screwed connections must be checked for tightness and firm seating. Oil change is due after 8,000 operating hours (only for oils supplied or approved by Elmo Rietschle). The cooling fan must be checked at least annually; the motor is maintained per manufacturer instructions; the integrated frequency inverter is maintenance-free; safety devices and safety measuring/control/regulating equipment are function-tested every six months; general overhaul by Elmo Rietschle Service after 40,000 operating hours.
- Monthly: check connection-box and cable-entry openings for leaks and re-close if needed.
- Monthly: clean ventilation openings on the machine and cooling fins on the motor.
- Monthly: check discharge-air connection for contamination if connected.
- Monthly: check oil level (Chapter 7.4.1) and clean the vacuum pump (Chapter 7.5).
- Depending on extracted-medium contamination: clean non-return valve and clean filter with strainer (Chapter 7.6).
- Drain condensate from silencer depending on contamination, at least monthly (Chapter 6.3.8).
- After 3,000 operating hours, at latest after 6 months: check piping and screwed connections for tightness and firm seating; re-tighten if necessary.
- After 8,000 operating hours: oil change (interval applies only to oils supplied or approved by Elmo Rietschle).
- At least annually: check cooling-air fan for firm mounting and damage (Chapter 7.7.2).
- Motor maintenance, lubrication and cleaning per manufacturer instructions (Chapter 7.7.1).
- Every six months: function test of safety devices and safety measuring, control and regulating equipment (Chapter 7.8).
- After 40,000 operating hours: general overhaul of the central vacuum system by Elmo Rietschle Service.
Before maintenance work: disconnect the electrical supply and secure it against reconnection, vent the machine to atmospheric pressure, and allow the machine to cool completely. Exception: for an oil change the pump should still be warm because the oil then drains better. A warning sign 'Caution, maintenance work in progress!' must be posted.
- Disconnect electrical supply and secure against reconnection.
- Vent the machine to atmospheric pressure.
- Allow the machine to cool completely.
- Exception for oil change: pump should still be warm so the oil drains better.
- Post warning sign 'Caution, maintenance work in progress!'.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Suction pressure range for permanent vacuum operation is 200–700 mbar (abs.). p.18 ↗ | Select and set the target pressure within this range; operation outside it is not a permitted operating mode. | VLR 1000 HV+ / C-VLR 1000 |
| Maximum pumping speed with free suction is 950 m3/h at 50 Hz. p.18 ↗ | Use this as the upper capacity limit for system sizing at 50 Hz. | VLR 1000 HV+ / C-VLR 1000 |
| Maximum permissible back pressure on the discharge side is +50 mbar. p.18 ↗ | Discharge piping and silencer must be sized so that +50 mbar is never exceeded. | VLR 1000 HV+ / C-VLR 1000 |
| Nameplate data at 25/50 Hz: 200/200 mbar(abs.), 475/950 m3/h, 1497/2945 1/min, 9.25/18.50 kW. p.17 ↗ | Defines the speed, capacity and power envelope of the C-VLR 1000 (29) variant. | C-VLR 1000 (29), ID 102781F001 |
| Switching frequency of about 10 times per hour or elevated ambient and suction temperatures may exceed motor winding and bearing limits. p.18 ↗ | Such duty conditions must be checked with the manufacturer before selection. | VLR 1000 HV+ / C-VLR 1000 |
| Oil is filled at the oil fill point (Fig. 2/H) up to the middle of the oil sight glass (Fig. 2/I, I1). p.21 ↗ | Defines the correct oil level for commissioning and top-up. | VLR 1000 HV+ |
| Electrical installation must comply with EN 60204 and be performed only by a qualified electrician. p.21 ↗ | Installation must follow the standard; the operator must provide the main switch. | VLR 1000 HV+ |
| No neutral conductor is required for connecting the frequency inverter. p.21 ↗ | Supply wiring to the inverter can be designed without an N conductor. | VLR 1000 HV+ |
| All metal housing parts must be earthed according to the wiring diagram and the earthing function verified. p.21 ↗ | Earthing is mandatory and must be checked before commissioning. | VLR 1000 HV+ |
| Supply lines must be protected against overcurrent and overvoltage, e.g. by installing a circuit breaker. p.21 ↗ | External overcurrent/overvoltage protection is required on the supply side. | VLR 1000 HV+ |
| Oil change interval is 8,000 operating hours, valid only for oils supplied or approved by Elmo Rietschle. p.36 ↗ | Using other oils invalidates the stated interval; the interval depends on load, operating conditions and oil type. | VLR 1000 HV+ |
| Piping and screwed connections must be checked for tightness and firm seating after 3,000 operating hours, at latest after 6 months. p.36 ↗ | Scheduled leak/torque check is required to maintain system tightness. | VLR 1000 HV+ |
| Condensate must be drained from the silencer depending on contamination, at least once per month. p.36 ↗ | Monthly condensate drain is the minimum maintenance requirement. | VLR 1000 HV+ |
| Safety devices and safety measuring, control and regulating equipment must be function-tested every six months. p.36 ↗ | Recurring functional test of safety equipment is mandatory. | VLR 1000 HV+ |
| General overhaul of the central vacuum system by Elmo Rietschle Service is due after 40,000 operating hours. p.36 ↗ | Plan a manufacturer service overhaul at 40,000 operating hours. | VLR 1000 HV+ |
| Before maintenance: disconnect and secure the electrical supply, vent the machine to atmospheric pressure and let it cool completely; for oil change the pump should still be warm. p.36 ↗ | Defines the safe isolation and cooling sequence for maintenance work. | VLR 1000 HV+ |
| Elastic vibration-damping elements are recommended for mounting the unit. p.20 ↗ | Use elastic mounts to reduce transmission of vibration to the building/piping. | VLR 1000 HV+ |
| Outdoor installation requires protection from environmental influences, e.g. a protective roof. p.18 ↗ | An outdoor unit must be sheltered. | VLR 1000 HV+ |