Operating Instructions — (EN)
Technical Reference Summary
Covered Models & Document Scope
L-BV7N series liquid-ring vacuum pumps/compressors, types 2BV7060, 2BV7061, 2BV7070 and 2BV7071. Variants -2 and -3 are listed for 2BV7060, 2BV7070 and 2BV7071; 2BV7061 is listed as -1. Document edition 07.2019, 610.00187.40.000.
Section-by-Section Technical Breakdown
Mechanical data, electrical data reference and operating conditions for the L-BV7N series. Includes weights, minimum heat-dissipation distances, noise levels, temperature limits, pressure limits, nominal operating-liquid flow rates and priming filling amounts.
- Weights range from approx. 20 kg (2BV7060-2) to 68 kg (2BV7071-3).
- Minimum distance from fan guard to adjacent surface: 34 mm for 2BV7060/2BV7061, 53 mm for 2BV7070/2BV7071.
- Noise level measured per EN ISO 3744 at 1 m with medium throttling (100 mbar abs.) and connected lines, tolerance ±3 dB(A).
- Electrical data is given on the drive motor rating plate.
- Pumped gas/vapor and operating-liquid temperature max. +80 °C; operating-liquid min. +5 °C, nominal +15 °C; ambient +5 to +40 °C.
- Max. discharge pressure during vacuum-pump operation 1.3 bar abs.; max. permissible pressure in pump-motor unit 8 bar abs.
- Max. discharge pressure during compressor operation depends on type and frequency (e.g. 2BV7071: 3.5 bar abs. at 50 Hz, 2.2 bar abs. at 60 Hz).
- Nominal operating-liquid flow rate and priming filling amount are tabulated per type and frequency.
Describes the liquid-ring principle: an eccentrically arranged impeller in a cylindrical housing with operating liquid forming a rotating ring. Gas is drawn in through the inlet port, compressed and discharged through the discharge port.
- Components: discharge connection (1), operating-liquid port (2), inlet connection (3), impeller (4), housing (5), discharge port (6), inlet port (7), operating liquid (8).
- Impeller is arranged eccentrically relative to the housing.
- Operating liquid is fed via the operating-liquid port and discharged together with the pumped gases/vapors via the discharge connection.
- During rotation the liquid ring is concentric to the housing and eccentric to the impeller, creating increasing cell volume for suction and decreasing volume for compression.
Defines self-priming operation and operation with operating-liquid feed (manual or automatic). The operating mode determines how and when the unit is filled with operating liquid and how it is commissioned.
- Self-priming operation: the pump-motor unit automatically sucks in operating liquid; flow rate is automatically adjusted.
- Operation with operating-liquid feed: the unit does NOT automatically suck in operating liquid; a nominal operating-liquid flow rate or pre-pressure must be set.
- Manual operation uses a stop valve to switch operating-liquid feed on and off.
- Automatic operation uses a solenoid valve that opens when the motor/pump-motor unit is switched on and closes when switched off.
Installation requirements for the pump-motor unit, including mounting position, surface, heat dissipation clearances, vibration limit and bolting. Also covers electrical connection of the motor and connection of pipes/hoses.
- Install on level, stationary surfaces with shaft horizontal; maximum installation height 1000 m above sea level.
- Comply with minimum distances for heat dissipation from Chapter 4.1.
- Maximum permissible vibration velocity veff = 4.5 mm/s.
- Bolt feet to supporting surface: 2BV706 with 4 x M8-6.8; 2BV707 with 4 x M10-6.8.
- Electrical connection per national/local regulations and terminal-box circuit diagram; connect protective conductor.
- Terminal plate tightening torques: M4 = 0.8–1.2 Nm; M5 = 1.8–2.5 Nm.
- Clearance between bare live parts and to ground at least 5.5 mm at Vn ≤ 690 V.
- Use motor circuit breakers set to the nominal current on the rating plate.
- For converter supply use shielded cables with shield installed on both sides.
- Pipe/hose connections: operating-liquid port G ¼", cavitation protection connection G ¼", drain opening G ¼".
- Tightening torque for pipe connections on intake and discharge connections must not exceed 100 Nm.
- Install a start-up screen in the inlet pipe for the first 100 operating hours.
Pre-start checks, filling with operating liquid, direction-of-rotation check and start-up procedures for self-priming operation and operation with operating-liquid feed.
- Unit may only be started with fan guard and vacuum pump/compressor housing mounted, lines attached and tested for strength and leaks.
- Do not run dry; mechanical seal is destroyed in seconds without operating liquid.
- Maximum discharge pressure when gases/vapors are passed on is 1.1 bar abs.
- For self-priming operation, fill with operating liquid during installation; for operation with operating-liquid feed, fill after completing installation.
- For operation with operating-liquid feed, open the stop valve for approx. 20 seconds to fill the working area.
- Check direction of rotation by briefly switching on and comparing external fan rotation with arrows on motor mounting adapter and fan guard.
- Self-priming operation requires a vacuum of at least 900 mbar abs. in the inlet pipe at switch-on and liquid level at shaft center; during operation the reservoir level may not drop below approx. 1 m below shaft center.
- For operation with operating-liquid feed, set pre-pressure pA approx. 1 bar above inlet pressure pB.
Fault table listing symptoms, causes, remedies and the personnel responsible for each corrective action.
- Covers motor not starting, protective motor switch tripping, high power consumption, and failure to generate vacuum.
- Remedies include checking fuses/terminals/cables, freeing a jammed impeller, decalcifying, cleaning, correcting impeller gap, replacing impeller or motor bearings, throttling operating-liquid flow, reducing counter-pressure, sealing leaks and reversing direction of rotation.
- Work is assigned to Electrician, Operator or Service as appropriate.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Maximum temperature of pumped gases/vapors is +80 °C [+176 °F]. p.10 ↗ | At higher fluid temperatures, measures must be taken on the system to prevent burns, e.g. mount a separating safety device (cover). | whole series |
| Operating-liquid temperature: max. +80 °C, min. +5 °C, nominal +15 °C. p.10 ↗ | Operating liquid must be kept within these limits; minimum inlet pressure depends on operating-liquid temperature (Fig. 1). | whole series |
| Ambient temperature: max. +40 °C [+104 °F], min. +5 °C [+41 °F]. p.10 ↗ | Installation location must remain within this ambient range. | whole series |
| Max. discharge pressure during vacuum-pump operation: 1.3 bar abs. [18.8 psia]. p.10 ↗ | System back-pressure on the discharge side must not exceed this value in vacuum operation. | whole series |
| Max. permissible pressure in pump-motor unit: 8 bar abs. [116 psia]. p.10 ↗ | If higher pressures can occur in the system, corresponding protective devices must be provided. | whole series |
| Max. discharge pressure during compressor operation at inlet pressure p1 = 1 bar abs.: 2BV7060 2.0/2.4 bar abs. (50/60 Hz); 2BV7061 1.9/1.9 bar abs.; 2BV7070 3.0/2.5 bar abs.; 2BV7071 3.5/2.2 bar abs. p.10 ↗ | Compressor duty limits are type- and frequency-dependent; select the type accordingly. | 2BV7060, 2BV7061, 2BV7070, 2BV7071 |
| Nominal operating-liquid flow rate with dry air extraction and water at 15 °C: 2BV7060 0.20 m³/h; 2BV7061 0.23 m³/h; 2BV7070 0.28/0.34 m³/h (50/60 Hz); 2BV7071 0.45/0.55 m³/h (50/60 Hz). p.11 ↗ | Operating-liquid supply must be set to these nominal flow rates for proper operation. | whole series |
| Operating-liquid filling amount for priming: 2BV7060 0.40 l; 2BV7061 0.55 l; 2BV7070 0.80 l; 2BV7071 1.10 l. p.11 ↗ | Use these quantities when filling the working space before commissioning. | whole series |
| Minimum distance from fan guard to adjacent surface: 34 mm for 2BV7060/2BV7061; 53 mm for 2BV7070/2BV7071. p.10 ↗ | Maintain these clearances to ensure heat dissipation and cooling are not obstructed. | 2BV7060, 2BV7061, 2BV7070, 2BV7071 |
| Maximum permissible vibration velocity veff = 4.5 mm/s [0.177 in/s]. p.16 ↗ | Installation and foundation must ensure total vibration does not exceed this value for proper operation and long service life. | whole series |
| Feet bolting: 2BV706 uses 4 x M8-6.8; 2BV707 uses 4 x M10-6.8. p.17 ↗ | Use suitable securing elements of these sizes to bolt the unit to the supporting surface. | 2BV7060/2BV7061 (2BV706); 2BV7070/2BV7071 (2BV707) |
| Terminal plate tightening torques: M4 = 0.8–1.2 Nm; M5 = 1.8–2.5 Nm. p.18 ↗ | Electrical connections must be tightened to these torques for a permanently safe connection. | whole series |
| Clearance between bare live parts and between bare live parts and ground: at least 5.5 mm at nominal voltage Vn ≤ 690 V. p.18 ↗ | Ensure no protruding wire pieces and maintain this clearance in the terminal box. | whole series |
| Permissible supply deviations without reduction in performance: ±5 % voltage, ±2 % frequency. p.18 ↗ | Operating conditions must correspond to the motor rating plate within these tolerances. | whole series |
| Tightening torque for pipe connections on intake and discharge connections must not exceed 100 Nm [73.8 ft lbs]. p.20 ↗ | Avoid over-tightening pipe connections to prevent damage. | whole series |
| Self-priming operation requires a vacuum of at least 900 mbar abs. [13.1 psia] in the inlet pipe at switch-on, and the liquid level in the feed pipe/reservoir must be at the same level as the center of the unit shaft. p.24 ↗ | Pre-throttle on the inlet side and establish correct liquid level before starting in self-priming mode. | whole series |
| During self-priming operation the liquid level in the reservoir may not drop below approx. 1 m [3.28 ft] below the center of the unit shaft. p.24 ↗ | Reservoir and feed pipe must be arranged to maintain this minimum level during operation. | whole series |
| For operation with operating-liquid feed, set pre-pressure pA in the feed pipe approx. 1 bar [14.5 psi] above the inlet pressure pB. p.25 ↗ | Operating-liquid feed pressure must be regulated relative to inlet pressure. | whole series |
| Maximum discharge pressure when pumped gases/vapors are passed on is 1.1 bar abs. [16.0 psia]. p.22 ↗ | Ensure downstream system cannot exceed this pressure during commissioning and operation. | whole series |
| Installation height maximum 1000 m [3280 ft] above sea level. p.16 ↗ | Higher altitudes require consultation with service. | whole series |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Motor does not start, no motor noise. p.33 ↗ | At least two power supply leads interrupted. | Check fuses, terminals and cables for open circuit. Eliminate open circuit. | Carried out by: Electrician |
| Motor does not start, humming noise.. p.33 ↗ | One power supply lead interrupted. | Check fuses, terminals and cables for open circuit. Eliminate open circuit. | Carried out by: Electrician |
| Motor does not start, humming noise.. p.33 ↗ | Impeller is jammed. | Free shaft by turning. See Chapter 11.1, "Maintenance", Pg. 30. | Carried out by: Operator |
| Motor does not start, humming noise.. p.33 ↗ | Impeller is jammed. | Decalcify vacuum pump/compressor. See Chapter 11.1, "Maintenance", Pg. 30. | Carried out by: Operator |
| Motor does not start, humming noise.. p.33 ↗ | Impeller is jammed. | Drain and clean vacuum pump/compressor if necessary. See Chapter 11.1, "Maintenance", Pg. 30. | Carried out by: Operator |
| Motor does not start, humming noise.. p.33 ↗ | Impeller is jammed. | Check and correct impeller gap setting if necessary. | Carried out by: Service |
| Motor does not start, humming noise.. p.33 ↗ | Impeller defective. | Replace impeller. | Carried out by: Service |
| Motor does not start, humming noise.. p.33 ↗ | Motor bearings defective. | Replace motor bearings. | Carried out by: Service |
| Protective motor switch trips when motor is switched on. p.33 ↗ | Winding short-circuit. | Have winding checked. | Carried out by: Electrician |
| Protective motor switch trips when motor is switched on. p.33 ↗ | Motor overloaded. | Throttle operating-liquid flow rate. See Chapter 8.2, "Self-priming operation", Pg. 24 or 8.3, "Operation with operating-liquid feed", Pg. 25. | Carried out by: Operator |
| Protective motor switch trips when motor is switched on. p.33 ↗ | Counter-pressure at discharge connection too high. | Reduce counter-pressure. | Carried out by: Operator |
| Protective motor switch trips when motor is switched on. p.33 ↗ | Share of liquid also fed too high. | Reduce share of liquid also fed. | Carried out by: Operator |
| Protective motor switch trips when motor is switched on. p.33 ↗ | Impeller is jammed. | See "Motor does not start, humming noise." | Carried out by: Service |
| Power consumption too high. p.33 ↗ | Lime or other deposits. | Decalcify vacuum pump/compressor. See Chapter 11.1, "Maintenance", Pg. 30. | Carried out by: Operator |
| Power consumption too high. p.33 ↗ | Lime or other deposits. | Clean vacuum pump/compressor. See Chapter 11.1, "Maintenance", Pg. 30. | Carried out by: Operator |
| Unit does not generate vacuum. p.33 ↗ | No operating liquid. | Ensure proper operating-liquid flow rate. See Chapter 8.2, "Self-priming operation", Pg. 24 or Chapter 8.3, "Operation with operating-liquid feed", Pg. 25. | Carried out by: Operator |
| Unit does not generate vacuum. p.33 ↗ | Severe leak in the system. | Seal leak in the system. | Carried out by: Operator |
| Unit does not generate vacuum. p.33 ↗ | Wrong direction of rotation. | Reverse direction of rotation by interchanging two connecting leads. | Carried out by: Electrician |