Minichiller 600-H OLÉ

Contents

  1. Overview p. 1
    Product name and cover page of the datasheet
  2. Spec p. 2
    Technical data according to DIN 12876
  3. p. 2 table, 10 rows

Technical data according to DIN 12876

ParameterValue
Net weight36 kg
sound pressure level +/- 4 dB(A)56 dB(A)
Power supply requirement208-240V 1~/2~ 50/60Hz
max. current12 A
Fuse16 A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S540391

Engineering Facts

12 facts · every claim linked to a page
Selection

The unit is rated for a -20 to 100 °C operating range, so it suits both sub-ambient cooling and moderate heating duties.

Defines whether the chiller can cover the required process setpoints before any other sizing.

Source
“Operating temperature range -20...100 °C”
Performance

Cooling capacity falls from 0.6 kW at 15 °C to 0.15 kW at -20 °C, so low-temperature duty needs a much larger margin.

Cooling capacity must be checked at the actual working temperature, not at nominal conditions.

Source
“at 15°C 0,6 kW at 0°C 0,5 kW at -10°C 0,35 kW at -20°C 0,15 kW”
Safety

The refrigerant is R-290 (A3, H220), a flammable natural refrigerant, which affects room classification and ventilation requirements.

Flammable refrigerant classification drives installation location, ventilation and ignition-source restrictions.

Source
“Refrigerant (ASHRAE, GHS) R-290 (A3, H220)”
Installation

The pressure-suction pump uses M16x1 male connections, so mating hoses and fittings must match this thread.

Wrong thread on hoses or adapters prevents commissioning and risks leaks.

Source
“Pump connection M16x1 male”
Operation

Whisper mode reduces noise to 51 dB(A) but also cuts pump delivery to 14 l/min and 0.2 bar, so quiet operation costs hydraulic performance.

Noise-sensitive installations may need whisper mode, but the reduced pump curve must still satisfy the loop.

Source
“switch for whisper mode: Reduced sound pressure level: 51 dB(A): +/- 4 dB(A)”
Installation

The unit requires a 16 A fuse and draws up to 12 A on a 208-240 V single/two-phase supply.

Electrical supply and protection must be sized accordingly before installation.

Source
“max. current 12 A Fuse 16 A”
Installation

The enclosure is IP20, so it must be installed in a dry, protected location away from water spray.

IP20 limits where the chiller can be placed and what washdown or splash exposure is acceptable.

Source
“Degree of Protection IP20”
Operation

Ambient temperature must stay between 5 and 40 °C, and cooling capacity may drop above 20 °C room temperature.

Room conditions directly affect available cooling capacity and reliable operation.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Operation

The plastic pump is not resistant to acetone or polyglycols, so these media require a different pump material.

Fluid compatibility must be confirmed before selecting the standard pump version.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Maintenance

For freeze protection, water should be mixed with glysantine or ethylene glycol rather than used neat.

Correct heat-transfer fluid preparation prevents freezing and protects the evaporator.

Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Installation

Single/two-phase units are delivered with a country-specific plug only if specified at ordering.

The plug type must be stated on the order or the unit may arrive without the required local connection.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Compliance

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.

Site power quality must be checked against these combined tolerances to avoid invalid supply conditions.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”