A 3004 H/X — instruction manual a 2504 xn a 3004 xn
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum A 2504 / A 3004 multi-stage Roots pumps (dry pumps for harsh applications), software V.3.04 and higher. Variants: H (harsh), X (corrosive), XN (very corrosive) versions. Part number matrix F4{H|X|N}b7cSSg6i01l0 encodes model (A 2504=J, A 3004=I), voltage (low/high voltage 60 Hz), exhaust (check valve or SEPM check valve), and 'c' depends on customer configuration. Options: temperature management STD/EHT/ELT, SEPM, SEMI, IHN (Internal Hot Nitrogen), V-Box.
Section-by-Section Technical Breakdown
Identifies product versions (A 2504H/X/XN, A 3004H/X/XN), scope of delivery, HMI components and connectors (J1–J8, S1, S2), and the Hand-Held Remote control keys and display elements.
- Delivery includes: pump, EMS cover plug, water connectors (2), nitrogen connector, electrical connector, HHR + cable, manual, oil can(s)
- HHR indicators: green = running, yellow = warning, red = alarm
- HHR keys: CONT., ROOTS, PURGE, AUX, START/STOP plus menu navigation keys
- Display option indicators: R (Roots), P (purge), H (IHN), S (stand-by purge), I (manual inlet valve)
- Keypad membrane: never use pointed objects
Horizontal installation with vertical pumping axis, inlet on top; seismic anchoring with brackets torqued to 62 N·m; oil filling (1.21 L total per pump); water and nitrogen circuit connection; pumping line connection; leak tightness check; electrical connection; first-time start-up and rotation direction check.
- Seismic bracket bolts/scres torque: 62 N·m (all steps)
- Oil capacity per pump (A 2504 & A 3004): FB 0.28 L, Roots gear side 0.55 L, Roots motor side 0.38 L, total 1.21 L; fill to mid-point of sight glass
- Water circuit: female connector IN, male OUT; max pressure 101 psi (7 bar); use regulated water, softened/non-aggressive recommended
- Nitrogen tubing: 6 mm OD / 4 mm ID; flow display guaranteed up to 120 slm, above that only indicative
- Close nitrogen pressure regulator (turn knob counter-clockwise) before pressurizing to avoid internal damage
- Inlet parts must withstand negative pressure of 1·10⁻³ hPa absolute
- Use flexible tubes to reduce vibration transmission; make inlet line short/straight, diameter ≥ pump inlet flange ID
- Cover venting: 50 mm diameter nozzle with differential pressure sensor; exhaust box must be connected
Powering on/off, pumping start-up and shutdown, auto-restart configuration, Roots control option, emergency stop and restart, prolonged stoppage, use of two remote controls, operation monitoring and configuration saving.
- HHR control mode selected via [DEFINITION][CONTROL MODE][HHR]
- ROOTS/PURGE/AUX keys operate locally only when the corresponding [DEFINITION] command is [ENABLED]
- Auto-restart configurable after power loss or fault conditions
Configuration of nitrogen injection (management mode, flow fault, purge prolongation), IHN hot nitrogen with temperature regulation, exhaust pressure monitoring (SEPM), water circuit description, FB/Roots temperature regulation, pump heating, inlet isolation valve management, motor power/rotation frequency monitoring, seizing detection, IDLE mode, analog/logic inputs, SEMI pump configuration.
- Nitrogen flow fault indication with interlock capability
- IHN temperature regulation via dedicated option
- SEPM (Silencer Exhaust Pressure Measurement) monitors exhaust pressure with warning/alarm levels
- Management of inlet isolation valve via connector J4
- Monitoring of motor power, rotation frequency and seizing
- IDLE mode operating principle for reduced operation
Control modes: HHR remote, J1 REMOTE connector, J3 user connector, J4 isolation valve connector, J5 Roots connector, plus emergency stop command wiring.
- J1: REMOTE control connector
- J2: RS-232, J6: RS-232/RS-485, J7: RS-485 serial links
- J4: inlet isolation valve control
- J5: Roots 2 control
- Emergency stop via dedicated EMS connector; certain components stay live between connector and breaker when stopped
Safety instructions, maintenance frequency, on-site maintenance, freeing up the functional block, exchange procedure for replacement product (disconnect, drain water circuit, prepare for shipping), prolonged shutdown and recommissioning, disposal.
- Drain the water circuit before disconnecting/shipping
- Never store a used pump – return to service center
- Free up the functional block procedure for maintenance
Fault message tables and troubleshooting: pump/Roots fails to start; pump running with HHR fault message; pump runs but performance inadequate.
- Faults displayed via HHR with warning (yellow) / alarm (red) indicators
- Troubleshooting split into: no-start, running-with-fault, inadequate-performance
General, technical, environmental, cooling water, nitrogen, and electrical characteristics, dimensions, weight distribution/center of gravity and required maintenance space. Appendix covers electrical component locations, circuit breaker adjustment, and monitoring sensor locations.
- Mains voltage ranges: 200–230 V and 380–480 V, 50/60 Hz, three phases, four wires
- Example rating plate: SCCR 10 kA, 25 A full load current
- Pump weight ~250 kg (rating plate example); weight/center of gravity vary by model
- Appendix includes circuit breaker adjustment and monitoring sensor locations
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Total oil fill per pump is 1.21 L (FB 0.28 L, Roots gear side 0.55 L, Roots motor side 0.38 L), identical for A 2504 and A 3004. p.23 ↗ | Order correct Pfeiffer Vacuum oil (A113) and fill each housing to mid-sight-glass; only manufacturer's oil is allowed. | A 2504 and A 3004 all variants |
| Ships WITHOUT oil – filling is mandatory before first start (label: 'ROOTS PUMP SHIPPED WITHOUT OIL'). p.8 ↗ | Do not power on before completing oil fill; damage otherwise. | whole series |
| Seismic bracket and reinforcing rail bolts must be torqued to 62 N·m. p.22 ↗ | For seismic installations, customer supplies floor bolts; use this torque on all three bracket attachment steps. | whole series, seismic option |
| Water circuit maximum pressure label: 101 psi (7 bar). p.7 ↗ | Cooling water supply must be regulated and below 7 bar; use softened/non-aggressive water and inlet filter if solid pollution exceeds spec. | whole series |
| Nitrogen connection uses 6 mm OD / 4 mm ID tubing; displayed flow value is guaranteed only up to 120 slm. p.25 ↗ | Size nitrogen supply lines accordingly; treat HHR flow readings above 120 slm as indicative only. | whole series |
| Manual shutoff valves on water and nitrogen supply must be installed within 3 m of the pump. p.11 ↗ | Plan plant layout and LO/TO points accordingly before installation. | whole series |
| Pumps are shipped pressurized with nitrogen and sealed; for storage after unsealing, pressurize to 200 hPa relative pressure. p.16 ↗ | Keep blanking plates on until connected to pumping line; use 200 hPa N₂ for storage up to 1 year. | whole series |
| Connected inlet-side chambers must withstand negative pressure of 1·10⁻³ hPa absolute. p.27 ↗ | Verify upstream chamber/vessel integrity before evacuation. | whole series |
| Cover venting nozzle diameter: 50 mm, with differential pressure sensor; exhaust box required for proper venting. p.27 ↗ | Exhaust extraction must generate sufficient differential pressure per SEMI configuration; include exhaust box in line design. | SEMI-configured pumps |
| LEL detection in extraction system must trigger gas shutoff at 25% LEL; oxidizer concentration must not exceed 60% of MOC (NFPA 69-2019 §7.7.2.5). p.12 ↗ | Mandatory interlock design for flammable/pyrophoric processes; risk assessment per EN 50495 required from user/integrator. | whole series in flammable/pyrophoric service |
| Mains supply: 200–230 V or 380–480 V, 50/60 Hz, three-phase four-wire; example SCCR 10 kA, 25 A full-load current. p.7 ↗ | Verify facility supply and breaker ratings (SCCR ≥ available fault current) before connection. | whole series, per voltage variant (low/high voltage) |
| Software version must be V.3.04 or higher for this manual to apply. p.6 ↗ | Check firmware version before using documented settings/options. | whole series |
| Emergency stop stoppage: components between electrical connector and breaker remain energized. p.11 ↗ | Mains disconnect must remain visible and accessible; LO/TO required before any electrical work. | whole series |
| Pump must operate horizontal, on its feet (not casters), pumping axis vertical, inlet on top. p.22 ↗ | Check with spirit level and lower feet onto floor; do not leave load on casters during operation. | whole series |
| XN versions are classified dual-use goods (Category 2B350i, EC regulation 428/2009). p.13 ↗ | Export/import licenses may be required for international shipment of very-corrosive variants. | XN variants only |
| Options available at ordering: temperature management STD/EHT/ELT, SEPM, SEMI, IHN, V-Box; part-number matrix F4[H|X|N]b7cSSg6i01l0; not all option combinations available. p.6 ↗ | Decode and order via the matrix in §1.1.2; verify option availability with Pfeiffer Vacuum before specifying. | whole series |
| Pump weight approximately 250 kg (rating plate example); casters for short moves only; lifting device required for hoisting via rings. p.8 ↗ | Do not handle manually; plan forklift/crane access and floor loading per weight distribution chapter. | whole series (weight varies by model) |
| Blasting plates' stock O-rings are not compatible with all applications; user/integrator must supply compatible O-rings. p.27 ↗ | Replace sealing O-rings to match process chemistry when connecting pumping line. | whole series |
| An interlock must stop process gas flow if nitrogen purge flow is interrupted. p.25 ↗ | Wire 'purge flow fault' signal to process gas supply shutoff; required for pyrophoric service. | whole series in pyrophoric service |
| Pump exhaust must always be connected to a dangerous-gas extraction system; exhaust line components must be rated above maximum pump-generated pressure. p.26 ↗ | Verify exhaust component pressure ratings and leak-test the line after installation. | whole series |