Instruction manual for Pfeiffer Vacuum+Fab Solutions COMBI WVD / COMBI WS vacuum booster pumping units (Roots pump PANDA WV + two-stage DuoVane rotary vane backing pump on a frame). Variants: COMBI WVD 0220, 0235, 0245, 0400, 0440, 0900, 0470, 0950, 1800, and COMBI WS 0245 WV2D, WS 0440 WV2D, WS 0900 WV2D (twin backing pump versions). Options: control cabinet, measuring/control unit (OmniControl), dust separator (SAS/STP), condensate separator (KAS), vacuum safety valve (HV), oil mist filter OME/ODK; Roots pump standard or magnetic coupling; stationary or mobile (castors) frames.

Section-by-Section Technical Breakdown

pp. 6-10
Safety, Limits of Use and Personnel Qualification

Defines risk levels, general precautions, intended use (evacuation of dry, inert gases to medium vacuum) and foreseeable misuse (corrosive/explosive media, open flanges, liquids, pressure generation). Sets operating limits and defines qualification levels for mechanical, electrical and maintenance personnel.

  • Installation limits: weatherproof indoor location, max. 2000 m altitude, horizontal with max. ±3° inclination, ambient +5°C to +45°C, max. 85% relative humidity
  • Surface temperature may exceed 70°C; use finger guards as needed
  • Electrical connection only by expert electrician per VDE 0105 / VDE 0100
  • Misuse includes pumping corrosive/reactive gases, explosive media or oxygen above atmospheric concentration, liquids, and operation in potentially explosive areas
  • Maintenance levels 1-3 defined; levels 2 and 3 require Pfeiffer technical education or service training
pp. 13-14
Product Description and Technical Data

COMBI WVD units combine a Roots pump (PANDA WV) with a two-stage DuoVane rotary vane backing pump, OME oil mist filter, and frame (stationary with anchor bores or mobile with castors). A performance table gives pumping speeds, final pressures, flange sizes, weights and power consumption for all 12 variants.

  • Supply scope: unit ready for connection on frame with connecting lines, counter flanges, operating fluid P3/D2/VSC100; optional control cabinet and OmniControl
  • WVD 0220: 200 m³/h at 1 hPa (50 Hz), final pressure 1.5E-03 hPa, inlet DN100 ISO-F, outlet DN40 ISO-KF, 218 kg, 1.15 kW
  • WVD 0440: 458 m³/h (50 Hz), final pressure 1.3E-03 hPa, inlet DN100 ISO-F, outlet DN63 ISO-F, 550 kg, 2.45 kW
  • WVD 0900: 825 m³/h (50 Hz), final pressure 9.2E-04 hPa, inlet DN160 ISO-F, 650 kg, 4.87 kW
  • WVD 1800 (largest): 1646 m³/h (50 Hz) / 2006 m³/h (60 Hz), final pressure 7.2E-04 hPa, inlet DN160 ISO-F, outlet DN100 ISO-F, 1025 kg, 5.65 kW
  • WS WV2D versions use 2x DuoVane 70 backing pumps, e.g. WS 0900 WV2D: 849 m³/h, final pressure 8.2E-04 hPa, 570 kg
pp. 15-18
Installation and Connections

Covers installation location requirements, preparation (fluid filling, media supply), vacuum-side and exhaust-side piping, and mains electrical connection. Emphasizes short suction lines, strain-free piping, start-up strainer use, and motor protection switch settings.

  • Vacuum line: keep as short as possible, at least the pump flange nominal diameter; use larger diameter for line lengths > 5 m
  • Use a start-up strainer (cone strainer) at the intake during initial commissioning due to fouling risk; note pumping speed loss
  • Exhaust line cross-section at least the pump exhaust nominal diameter; slope piping downward or fit condensate separator; no shut-off valves on exhaust side
  • Excess pressure hazard threshold: > 1500 hPa abs. in lines; when extracting exhaust gases, exhaust pressure must be ≥ 250 hPa above intake-side pressure
  • Three-phase motors shipped without connection accessories; motor protection switch setting must match motor rating plate; verify direction of rotation per component manual
  • Control-cabinet versions are fully internally wired with motors rotating in correct direction; phase sequence relay provides monitoring; measuring tube power supply has internal 100 mA microfuse
pp. 19-21
Operation incl. Control Cabinet

Pre-start checks (fluid levels, oiler, line connections, rotation direction), switch-on/off procedures, and control-cabinet operation with panel elements. Specifies warm-up and post-process purge practices to protect the operating fluid.

  • Run unit ~30 minutes after process completion with intake closed and gas ballast valve open to prevent oil contamination by condensation
  • Control cabinet: master switch 9.10 to '1', ON key 9.6 / OFF key 9.7; switch-on/off sequence dictated by controller; panel includes lamp test 9.9 and internal operating hours counter
  • Lockout: main switch off, secured with lock, key carried by responsible supervisor before maintenance
  • Critical: if Roots pump is switched off and stationary for > 5 minutes, wait at least 120 minutes after ventilation before restart to equalize rotor/housing temperatures
  • Exhaust-side shut-off units must open before or simultaneously with pump start
pp. 22
Malfunctions / Troubleshooting

Fault table listing problems (unit does not start, switches off after a while, does not attain ultimate pressure, pumping speed too low, fluid loss, unusual noises) with causes and remedies referencing component operating instructions.

  • Failure to start: check mains voltage/fuse, motor switch, thermal protection, dirty/damaged suction or pumping systems, defective motor
  • Low ultimate pressure: dirty pump/accessories, dirty operating fluid, system leak, dirty/damaged Roots pump overflow valve, low backing pump fluid level
  • Low pumping speed: undersized intake line, excessive exhaust pressure
  • Unusual noise: dirty suction chamber or silencer, damaged bearings/gear wheels, dirty overflow valve, defective motor bearing; magnetic-coupling Roots pump case: motor runs but pump does not
pp. 23-24
Maintenance

Maintenance intervals follow the individual component manuals; shorter intervals for extreme loads must be clarified with Pfeiffer service. Components may be removed for customer maintenance; safety precautions for contamination and electrical isolation are given.

  • Tighten connecting screws between backing and Roots pump regularly to 40-50 Nm (risk of loosening by vibration)
  • Unit is voltage-free only when mains plug disconnected; secure against restart before work
  • Decontaminate parts contaminated by pumped media before maintenance
  • Use lifting device for the heavy backing pump; gloves per EN 420, safety shoes per EN 347
  • Operating individual disassembled components is improper use and invalidates the declaration of conformity
pp. 25
Decommissioning, Storage Shutdown and Disposal

For shutdowns longer than one year, store indoors at -10°C to +40°C; in moist/aggressive atmospheres shrink-wrap air-tight with desiccant. Re-start after checking for contamination and moisture; dispose of materials per local regulations.

  • Long-term storage > 1 year: airproof shrink-wrapping plus desiccant bag required in moist or aggressive atmospheres
  • Before re-start: check for contamination/moisture; have Pfeiffer service clean if necessary
  • Change lubricants and operating fluids before restart after storage (corrosion/aging risk)
  • Decontaminate contaminated parts before disposal
pp. 26-30
Service Solutions, Spare Parts and Accessories

References Pfeiffer service offerings, spare parts (section 11) and accessories (section 12), plus EU and UK Declarations of Conformity (sections 13-14). Detailed part lists are in the referenced sections.

  • Optional accessories: SAS/STP dust separator, KAS condensate separator, HV vacuum safety valve, OME/ODK oil mist filter
  • Documentation for accessories is order-specific
  • EU and UK Declarations of Conformity included in the manual

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Installation limits: max altitude 2000 m above sea level, ambient +5°C to +45°C, max relative humidity 85%, horizontal orientation within ±3°, weatherproof indoor location. p.7 ↗ Exclude outdoor or high-altitude installations without mitigation; foundation must be level within 3°. whole series
Pumping speeds range from 200 m³/h (WVD 0220) to 1646 m³/h at 1 hPa/50 Hz (WVD 1800), with final pressures (gas ballast) from 1.7E-03 down to 7.2E-04 hPa. p.14 ↗ Selection basis for matching unit size to required pump-down time and ultimate pressure in medium vacuum. whole series
Inlet flanges: DN100 ISO-F for WVD 0220-0470 and WS 0245/0440, DN160 ISO-F for WVD 0900/0950/1800 and WS 0900; outlet flanges DN40 ISO-KF to DN100 ISO-F depending on variant. p.14 ↗ Vacuum plumbing and flange hardware must match the specific variant's connection sizes. per variant, see table
Weights range from 218 kg (WVD 0220) to 1025 kg (WVD 1800); max power consumption 1.15-5.65 kW. p.14 ↗ Lifting equipment, load-bearing capacity of floor and electrical supply sizing must be chosen per variant. per variant
Vacuum-side connection line must be at least the pump flange nominal diameter; use a larger diameter for line lengths > 5 m. p.16 ↗ Undersized or long suction lines cause pumping-speed loss; upsize piping for long runs. whole series
A start-up strainer (cone strainer) must be used at the intake during initial commissioning because system fouling must be expected even in clean processes. p.16 ↗ Install the strainer for first startup; remove it only when solid-particle ingestion risk is excluded; expect some pumping speed loss. whole series
Exhaust line must have no shut-off valves; excess pressure above 1500 hPa abs. in lines requires accident-prevention measures; extracted exhaust pressure must be at least 250 hPa above intake-side pressure. p.17 ↗ Design exhaust system unobstructed; downstream extraction must maintain the ≥250 hPa differential. whole series
Motors are three-phase, shipped without electrical connection accessories; a suitable motor protection switch is mandatory with setting matching the motor rating plate; rotation direction must be verified. p.17 ↗ Specify motor protection switch per motor nameplate and confirm rotation before first run. whole series
In control-cabinet versions, the phase sequence relay provides monitoring; the measuring-tube power supply contains an internal 100 mA microfuse. p.18 ↗ Include phase-sequence faults in diagnostics; stock/check the 100 mA microfuse when a gauge is connected. control-cabinet variants
If the Roots pump is switched off and stationary for more than 5 minutes, restart only after ventilation and a waiting period of at least 120 minutes to equalize rotor and housing temperatures. p.21 ↗ Prevents rotor seizure from differential cooling; embed in control interlocks or SOPs for rapid cycling. whole series (Roots pump)
After each process, run the unit approximately 30 minutes with intake line closed and gas ballast valve open before shutdown. p.19 ↗ Prevents condensation/corrosion contamination of the operating fluid; add to automatic purge routines. whole series
Connecting screws between backing pump and Roots pump must be checked regularly and tightened to 40-50 Nm. p.23 ↗ Vibration can loosen them causing the Roots pump to fall; add torque check to maintenance schedule. whole series
Storage and long-term shutdown: indoors at -10°C to +40°C; after storage > 1 year, change operating fluids and lubricants before commissioning. p.12 ↗ Plan fluid change after any extended storage; in humid/ aggressive atmospheres use shrink-wrap with desiccant. whole series
Intended use is restricted to evacuation of dry and inert gases to medium vacuum; corrosive/reactive gases, explosive media, oxygen above atmospheric concentration, liquids and sublimating substances are prohibited misuse. p.8 ↗ Process gases outside this envelope require prior consultation with Pfeiffer Vacuum+Fab Solutions. whole series
Surface temperature of the pumps can exceed 70°C depending on operating/ambient conditions. p.7 ↗ Provide finger guards and hot-surface warnings; use EN 420 protective gloves for maintenance after cooldown. whole series
Approved operating fluid/lubricant types are P3 / D2 / VSC100; use of non-approved fluids limits warranty and may prevent achieving rated performance. p.13 ↗ Only specify Pfeiffer-approved fluids; consult before any application-specific fluid substitution. whole series
COMBI WS WV2D variants use two DuoVane 70 backing pumps (e.g. WS 0900 WV2D: 849 m³/h at 1 hPa/50 Hz, final pressure 8.2E-04 hPa, DN160 inlet). p.14 ↗ Dual-backing-pump configurations offer redundancy/parallel capacity at defined performance points. COMBI WS 0245/0440/0900 WV2D
The operator must provide a mains isolation device (main switch or emergency-stop) enabling emergency shutdown of the unit. p.17 ↗ Include lockable mains disconnect in the site electrical design; lockout key carried by supervisor during maintenance. whole series