ACP 15 — product leaflet 40 global
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum ACP series dry multi-stage roots vacuum pumps, covering three models: ACP 15, ACP 28, ACP 40. Accessories/options mentioned: dust filter, external silencer, isolation valve, preventive maintenance packages, versions for corrosive gases, condensable vapor pumping, gas recirculation, fluorine-free pumping, and remote electronics for radiative environments.
Section-by-Section Technical Breakdown
Introduces the ACP 15-40 series of dry multi-stage roots vacuum pumps. Highlights hydrocarbon-free, oil- and contact-free operation, constant pumping speed with low ultimate pressure, and absence of wearing parts inside the compression chamber. Lists available accessories, spare parts and special gas/version options.
- Dry, hydrocarbon-free, oil- and contact-free operation
- Constant pumping speed, low ultimate pressure
- No wearing parts inside the compression chamber, long life cycle
- Accessories/options: dust filter, external silencer, isolation valve, preventive maintenance packages
- Special versions for corrosive gases, condensable vapor pumping, gas recirculation or fluorine-free pumping
- Remote electronic option for radiative environments
Provides a performance comparison table across ACP 15, ACP 28 and ACP 40, including pumping speed, ultimate pressures (with/without gas-ballast), power consumption, supply voltages, noise level, cooling and leak rate, plus a pumping speed curve diagram for 50/60 Hz. Includes flange sizes for inlet and outlet.
- Max. pumping speed: ACP 15 = 14 m³/h; ACP 28 = 27 m³/h; ACP 40 = 37 m³/h
- Ultimate pressure without dilution: 5·10⁻² mbar (ACP 15), 4·10⁻² mbar (ACP 28/40)
- Ultimate pressure with gas-ballast valve: 3·10⁻¹ mbar (ACP 15), 2·10⁻¹ mbar (ACP 28/40)
- Max. continuous inlet pressure: 1013 mbar (all models)
- Max. water pumping capacity: 80 g/h (ACP 15); 120–700 g/h depending on configuration (ACP 28/40)
- Power consumption at ultimate pressure: 0.45 kW (ACP 15), 0.7 kW (ACP 28/40); max.: 0.55 kW / 1.05 kW
- Supply voltage: 1-phase 100–230 VAC; 2-phase 200–440 VAC (all models)
- Sound pressure level at ultimate pressure <65 dB(A); air cooled
- Max. leak rate 5·10⁻⁷ hPa·l/s (all models)
- Inlet flange: DN 25 ISO-KF (ACP 15/28), DN 40 ISO-KF (ACP 40); outlet: DN 16 ISO-KF (ACP 15), DN 25 ISO-KF (ACP 28/40)
- Pumping speed curves given for 50 Hz and 60 Hz operation
Lists physical dimensions and weights for the three models, noting water pumping capacity is configuration-dependent, and directs readers to Pfeiffer Vacuum via a contact form.
- Dimensions (L x W x H): ACP 15 = 514 x 190 x 270 mm; ACP 28 and ACP 40 = 647 x 193 x 322 mm
- Weight: ACP 15 = 23 kg; ACP 28 = 30 kg; ACP 40 = 32 kg
- Water pumping capacity values marked as configuration-dependent
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| ACP 15 delivers max pumping speed of 14 m³/h, ACP 28 27 m³/h, ACP 40 37 m³/h. p.15 ↗ | Model selection by required pumping speed; only three discrete sizes available in this series. | Whole series |
| Ultimate pressure without dilution is 5·10⁻² mbar (ACP 15) and 4·10⁻² mbar (ACP 28/40); with gas-ballast valve it rises to 3·10⁻¹ and 2·10⁻¹ mbar respectively. p.15 ↗ | Closing the gas-ballast valve is required to reach lowest ultimate pressure; using gas-ballast costs roughly one decade of base pressure. | Whole series |
| All three pumps tolerate a maximum continuous inlet pressure of 1013 mbar. p.15 ↗ | Pumps can start at atmosphere without a backing/roughing pump, simplifying system design. | Whole series |
| Max. water pumping capacity is 80 g/h for ACP 15 and 120–700 g/h for ACP 28/40 depending on configuration. p.15 ↗ | Condensable water vapor handling varies strongly with configuration; must be verified for wet processes. | ACP 15 vs ACP 28/40 |
| Power consumption at ultimate pressure: 0.45 kW (ACP 15), 0.7 kW (ACP 28/40); max power consumption 0.55 kW and 1.05 kW respectively. p.15 ↗ | Size power supply and cabling for max consumption, not ultimate-pressure draw. | Whole series |
| Supply voltage: 100–230 VAC (1-phase) and 200–440 VAC (2-phase). p.15 ↗ | Pumps can be wired to common single-phase mains or higher industrial 2-phase supplies; check available site supply. | Whole series |
| Sound pressure level at ultimate pressure is below 65 dB(A) for all models. p.15 ↗ | Suitable for noise-lab environments without mandatory acoustic enclosure. | Whole series |
| Cooling method is air for all models. p.15 ↗ | No cooling water circuit required; ensure adequate ambient airflow around the pump. | Whole series |
| Maximum leak rate is 5·10⁻⁷ hPa·l/s. p.15 ↗ | Relevant for leak-rate budgeting of high-vacuum systems. | Whole series |
| Inlet flanges are DN 25 ISO-KF (ACP 15, ACP 28) and DN 40 ISO-KF (ACP 40); outlet flanges are DN 16 ISO-KF (ACP 15) and DN 25 ISO-KF (ACP 28/40). p.15 ↗ | Determines KF clamping hardware and centering rings needed for installation plumbing. | Per model as listed |
| Dimensions: ACP 15 = 514 x 190 x 270 mm, 23 kg; ACP 28 = 647 x 193 x 322 mm, 30 kg; ACP 40 = 647 x 193 x 322 mm, 32 kg. p.15 ↗ | ACP 28 and ACP 40 share the same footprint and mounting; plan chassis/enclosure space and load accordingly. | Per model as listed |
| The compression chamber contains no wearing parts and operates oil- and contact-free. p.15 ↗ | Process gas cannot be contaminated by hydrocarbons; suitable for clean applications and reduces maintenance in the pumping chamber. | Whole series |
| Optional versions exist for corrosive gases, condensable vapor pumping, gas recirculation and fluorine-free pumping, plus a remote electronic option for radiative environments. p.15 ↗ | Ordering must specify the correct variant for the process gas type or radiation environment; the standard model is not universally suitable. | Whole series |
| Pumping speed curves are provided for both 50 Hz and 60 Hz mains operation. p.15 ↗ | Pump performance differs with supply frequency; performance selection must reference the correct curve for the installation site. | Whole series |