Induztr
Engineering Digest Document Viewer Related Models

COBRA BC 0601 G — product leaflet cobra bc 0601 1200 a g global

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum COBRA BC series dry screw vacuum pumps with integrated vacuum booster, three variants: BC 0601 G, BC 1001 G, BC 1200 A. Two-page product brochure/datasheet covering applications, features, dimensional data and technical specifications.

Section-by-Section Technical Breakdown

pp. 1
Product Overview and Key Features

The COBRA BC 0601–1200 A/G are dry screw vacuum pumps combining a backing pump and an integrated vacuum booster on one compact base frame. They feature an advanced screw design, bell-shaped construction, patented self-balancing screws and direct water cooling. The pumps target semiconductor and deposition processes such as cold ALD, load lock/transfer chambers, metrology, lithography, PVD, RTA and oxide/silicon/metal etching.

  • High performance: advanced screw design, bell-shaped construction, patented self-balancing screws, excellent running qualities
  • Integrated vacuum booster on the pump unit
  • Suited for cold atomic layer deposition, load lock and transfer chambers, metrology, lithography, PVD, rapid thermal annealing and oxide/silicon/metal etching
  • Efficient: low cost of ownership, minimal maintenance, long service intervals, high uptime, direct water cooling
  • Compact: fit-in-place design, directly mounted canned motor, backing pump and booster combined on compact base frame
pp. 2
Technical Data and Specifications

This section provides the dimensional drawing reference, pumping speed curves (air at 20 °C, tolerance ±10%, 50/60 Hz), and full specification tables for the three models. Data covers pumping speed, ultimate pressure, motor ratings and speeds, power consumption, noise, cooling water and nitrogen consumption, weight, dimensions and connections.

  • Pumping speed curves measured on air at 20 °C with tolerance ±10%, shown for 50 Hz and 60 Hz operation
  • Nominal pumping speed: BC 0601 G 550/640 m³/h; BC 1001 G 870 m³/h; BC 1200 A 1200 m³/h
  • Ultimate pressure 0.003 hPa (mbar) for all models at 50/60 Hz
  • Backing pump motor 1.5 kW, 3000 min⁻¹ for all models; booster motors 1.5 kW (0601), 2.9 kW (1001), 4.0 kW (1200)
  • Sound pressure level 60 dB(A) (ISO 2151, KpA = 3 dB) for all models
  • Water consumption 3.0–4.0 l/min (0601, 1001) and 4.0–5.0 l/min (1200)
  • Nitrogen consumption 0–70 l/min (0601, 1001), 0–200 l/min (1200)
  • Gas inlet/outlet: DN 63 ISO-K / DN 40 ISO-KF (0601), DN 100 ISO-K / DN 40 ISO-KF (1001), DN 160 ISO-K / DN 40 ISO-KF (1200)
  • Weights approx. 320 kg (0601), 310 kg (1001), 360 kg (1200)
  • Specifications may vary with configuration, accessories, installation and operating conditions

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ultimate pressure is 0.003 hPa (mbar) for all three models at 50/60 Hz p.2 ↗ Suitable for high-vacuum process applications without a separate booster stage; vacuum booster is already integrated whole series
Nominal pumping speed: 550/640 m³/h (BC 0601 G, 50/60 Hz), 870 m³/h (BC 1001 G), 1200 m³/h (BC 1200 A) p.2 ↗ Model selection based on required throughput; BC 1200 A gives ~2.2× the speed of BC 0601 G whole series (per model)
Backing pump motor is 1.5 kW at 3000 min⁻¹ for all models; booster motors are 1.5 kW (0601 G), 2.9 kW (1001 G), 4.0 kW (1200 A) p.2 ↗ Electrical supply sizing must account for combined backing + booster motor rating, up to 5.5 kW total on the BC 1200 A whole series (per model)
Booster motor speed is 3000/3600 min⁻¹ (0601 G, 50/60 Hz) and 5400 min⁻¹ (1001 G and 1200 A) p.2 ↗ Larger models run the booster at higher speed; check coupling/bearing life and noise considerations for 5400 min⁻¹ operation whole series (per model)
Power consumption at ultimate pressure / idle mode: 1.25/1.35 kW (0601 G), 1.7/1.2 kW (1001 G), 1.9/1.3 kW (1200 A) p.2 ↗ Base-load energy cost estimate for idle process chambers; note idle power can be lower than ultimate-pressure power on 1001 G and 1200 A whole series (per model)
Minimum cooling water consumption is 3.0–4.0 l/min (0601 G, 1001 G) and 4.0–5.0 l/min (1200 A) p.2 ↗ Cooling water circuit must be sized and verified before commissioning; direct water cooling — no separate cooling unit whole series
Nitrogen purge consumption range 0–70 l/min (0601 G, 1001 G) and 0–200 l/min (1200 A) p.2 ↗ Process gas/dilution supply must be capable of up to 200 l/min for the BC 1200 A in purge applications whole series (per model)
Gas inlet/outlet connections: DN 63 ISO-K in / DN 40 ISO-KF out (0601 G); DN 100 ISO-K / DN 40 ISO-KF (1001 G); DN 160 ISO-K / DN 40 ISO-KF (1200 A) p.2 ↗ Matching flange hardware and foreline piping must match the inlet size; outlet is uniformly DN 40 ISO-KF across the series whole series (per model)
Footprints: 905 × 354 × 660 mm (0601 G, ~320 kg) and 1054 × 425 × 615 mm (1001 G ~310 kg; 1200 A ~360 kg) p.2 ↗ Installation planning: verify floor loading and clearance; the 0601 G has a notably narrower footprint (354 mm) whole series (per model)
Sound pressure level is 60 dB(A) (ISO 2151, KpA = 3 dB) for all models p.2 ↗ Meets typical fab floor noise limits without special acoustic enclosures; tolerance KpA = 3 dB applies whole series
Pumping speed data tolerance is ±10%, measured on air at 20 °C p.2 ↗ Process sizing calculations should include this tolerance margin; curves valid for air at 20 °C only whole series
Motors are directly mounted canned motors (no shaft seals) p.1 ↗ Supports dry, contamination-free operation relevant to semiconductor/lithography applications whole series
Specifications may vary depending on configuration, accessories, installation and operating conditions p.2 ↗ Final design must be confirmed against the detailed technical data for the exact configuration ordered whole series