COBRA DS 8161 F — product leaflet cobra ds 5161 9161 b global
Technical Reference Summary
Covered Models & Document Scope
Busch COBRA DS 5161 B and COBRA DS 9161 B dry screw vacuum pumps (2-page datasheet, dated 01.04.2026). Integrated vacuum booster variant with directly mounted canned motor, indirect water cooling.
Section-by-Section Technical Breakdown
The COBRA DS 5161/9161 B are dry screw vacuum pumps with advanced screw design and an integrated vacuum booster. They target semiconductor-type processes such as chemical vapor deposition, rapid thermal processing, and atomic layer deposition. Key selling points are low cost of ownership, long service intervals, high hydrogen throughput, and a compact fit-in-place design.
- Dry screw principle with integrated vacuum booster
- Suited for CVD, RTP, and ALD applications
- High hydrogen throughput
- Indirect water cooling; directly mounted canned motor
- Low maintenance, long service intervals, high uptime
The datasheet lists key performance data for both models: nominal pumping speed, ultimate pressure, motor ratings and speeds, power consumption, noise, cooling water and nitrogen consumption, weight, dimensions, and connections. Pumping speed curves (air at 20°C, tolerance ±10%) and a dimensional drawing are provided. Both models share a DN200 inlet and DN63 outlet.
- Nominal pumping speed: 4300 m³/h (DS 5161 B), 6220 m³/h (DS 9161 B)
- Ultimate pressure: 0.001 hPa (mbar) for both models
- Backing pump motor: 15 kW @ 3600 min⁻¹; booster motor: 15 kW (5161) / 20 kW (9161) @ 3000 min⁻¹
- Power consumption at ultimate pressure / idle: 11.5/9 kW (5161), 13/11 kW (9161)
- Sound pressure level < 75 dB(A) (ISO 2151, KpA = 3 dB)
- Cooling water: min. 15 l/min (5161), min. 14 l/min (9161); nitrogen: 0–200 l/min
- Weight approx. 1500 kg (5161), 1875 kg (9161)
- Dimensions: 1550×722×1452 mm (5161), 1567×810×1615 mm (9161)
- Gas inlet/outlet: DN 200 / DN 63 for both models
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ultimate pressure is 0.001 hPa (mbar) for both DS 5161 B and DS 9161 B. p.2 ↗ | Suitable for high-vacuum semiconductor processes; system base pressure limited by this value. | whole series |
| Nominal pumping speed: 4300 m³/h (5161 B) vs 6220 m³/h (9161 B); pumping speed curves measured on air at 20°C with ±10% tolerance. p.2 ↗ | Size selection should include the ±10% curve tolerance margin. | whole series |
| Backing pump motor is 15 kW at 3600 min⁻¹ on both models; booster motor is 15 kW (5161 B) or 20 kW (9161 B) at 3000 min⁻¹. p.2 ↗ | Electrical supply and protection must be sized for two motors per pump. | whole series |
| Power consumption at ultimate pressure / idle mode: 11.5 / 9 kW (5161 B) and 13 / 11 kW (9161 B). p.2 ↗ | Actual energy cost is below nominal motor rating in steady-state; useful for operating cost calculations. | whole series |
| Sound pressure level < 75 dB(A) per ISO 2151 (KpA = 3 dB). p.2 ↗ | Typically no special noise abatement needed for most workplace limits. | whole series |
| Cooling water requirement: minimum 15 l/min (5161 B) or 14 l/min (9161 B); cooling is indirect water cooling. p.2 ↗ | Cooling water circuit with these flow rates must be provided at installation. | whole series (per model) |
| Nitrogen consumption range is 0–200 l/min. p.2 ↗ | Purge gas supply sized up to 200 l/min for dilution/purging duty. | whole series |
| Gas connections: DN 200 inlet, DN 63 outlet on both models. p.2 ↗ | Pipeline and flange hardware standardized across both models. | whole series |
| Weights approx. 1500 kg (5161 B) and 1875 kg (9161 B). p.2 ↗ | Floor loading, lifting equipment, and foundation must handle ~1.5–1.9 t. | whole series |
| Dimensions: 1550×722×1452 mm (5161 B), 1567×810×1615 mm (9161 B). p.2 ↗ | Fit-in-place layout planning; both footprint sizes are similar despite ~45% higher speed of the 9161. | whole series |