HiLobe 1004 — product leaflet hilobe 1004 2104 global
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiLobe 1004, 1304 and 2104 hermetically sealed vacuum boosters (Roots-type, canned motor, IE5 synchronous motor). Each is driven by the RC 5500 electronic drive unit; accessories/options include Profinet converter, barrier gas kit, gear chamber evacuation, flushing device, temperature/pressure monitoring, extension cables up to 30 m, OmniControl, and drive electronics variants (box version, cabinet mounting plate, or without drive electronics).
Section-by-Section Technical Breakdown
Highlights reliability through intelligent condition monitoring with integrated sensors, high pumping speed with best performance-to-size ratio, and efficiency via an IE5 hermetically sealed synchronous motor (canned motor, no shaft seals), variable speed drive and extended maintenance intervals.
- Intelligent condition monitoring via integrated sensors for high up-time
- High pumping speed, best performance-to-size-ratio
- Hermetically sealed synchronous motor (IE5), canned motor design, no shaft seals
- Variable speed drive and optimized rotor geometries
- Extended maintenance intervals
Lists the available accessories and electronic drive options for the HiLobe series.
- Profinet converter
- Barrier gas kit (plastic or stainless steel)
- Gear chamber evacuation
- Flushing device (spray lance)
- Temperature and pressure monitoring (inlet and exhaust side)
- Extension cable package (possible up to 30 m)
- OmniControl
- Operating fluids
- Electronic drive options: box version, mounting plate for switch cabinet integration, without drive electronics
Specification table for HiLobe 1004, 1304 and 2104 covering pumping speed, rotational speed, differential pressures, flanges, electrical data, environmental limits, operating fluid, leak rate, dimensions and weight, plus dimensional drawing and pumping speed curves (50/60 Hz).
- Nominal pumping speed: 250-1050 m³/h (1004), 260-1300 m³/h (1304), 260-2100 m³/h (2104)
- Rotational speed: 1500-6000 rpm (1004), 1500-7500 rpm (1304), 1500-12000 rpm (2104)
- Max. differential pressure at max. speed: 52/35/12 hPa (1004/1304/2104); 75 hPa at min. speed for all models
- Main and secondary flanges: DN 100 ISO-F or DN 100 PN 16 (all models)
- Input voltage 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
- Rated power at full speed: 2 kW (1004), 2.5 kW (1304), 3.5 kW (2104); RC 5500 electronic drive unit; 16 A recommended mains fuse
- Interfaces PV.can and RS485; active air cooling; ambient temperature 5-40 °C; shipping temperature -10-40 °C
- Sound pressure level (EN ISO 2151) at 1 hPa inlet: 67/68/69 dB(A)
- Operating fluid D2, filling 0.65 l (all models)
- Protection degree IP54 / type 12; integral leak rate 1E-06 Pa·m³/s
- Dimensions 875 x 282 x 240 mm, weight approx. 115 kg (all models)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max differential pressure depends on rotational speed: 75 hPa at minimum speed vs 52 hPa (HiLobe 1004), 35 hPa (1304) and 12 hPa (2104) at maximum speed. p.2 ↗ | For high differential-pressure applications, run the booster at reduced speed or use a suitable backing pump; the 2104 tolerates only 12 hPa at full 12000 rpm. | HiLobe 1004, 1304, 2104 |
| Nominal pumping speed ranges: 250-1050 m³/h (1004), 260-1300 m³/h (1304), 260-2100 m³/h (2104). p.2 ↗ | Select model size by required speed range; all three share the same footprint (875 x 282 x 240 mm), so upgrading is dimensionally trivial. | HiLobe 1004, 1304, 2104 |
| Rotational speeds: 1500-6000 rpm (1004), 1500-7500 rpm (1304), 1500-12000 rpm (2104). p.2 ↗ | Speed is variable (RC 5500 drive), allowing throughput control; do not exceed model-specific max speed. | HiLobe series |
| Power supply requirement is 380-480 V AC (±10%), 50/60 Hz, three-phase, with a recommended 16 A mains fuse. p.2 ↗ | Verify supply voltage window and fuse sizing before installation; no 230 V single-phase option exists. | whole series |
| Rated motor power at full rotational speed: 2 kW (1004), 2.5 kW (1304), 3.5 kW (2104). p.2 ↗ | Drive/cabinet sizing and energy budgeting per model. | HiLobe 1004, 1304, 2104 |
| The drive electronics is the RC 5500 electronic drive unit; also available as box version, mounting plate for switch cabinet integration, or without drive electronics. p.1 ↗ | Drive placement (on-pump vs remote cabinet) must be chosen at ordering; matching RC 5500 is mandatory. | whole series |
| Motor is a hermetically sealed IE5 synchronous canned motor with no shaft seals and PTC motor protection. p.1 ↗ | No shaft-seal wear or leakage path via the shaft; PTC trip must be wired into the monitoring circuit. | whole series |
| Integral leak rate is 1E-06 Pa·m³/s and protection degree is IP54 / type 12. p.3 ↗ | Suitable for high-vacuum, leak-tight systems; enclosure only for indoor/protected environments per IP54. | whole series |
| Operating fluid is D2 with a fill volume of 0.65 l for all models. p.3 ↗ | Stock D2 oil for commissioning and oil changes; fill quantity identical across models. | whole series |
| Ambient temperature limit is 5-40 °C; shipping/storage temperature is -10-40 °C. p.2 ↗ | Install in temperature-controlled rooms; antifreeze precautions not required above -10 °C during transport/storage only. | whole series |
| Cooling is active air cooling on all models. p.2 ↗ | Ensure free airflow around the unit; no cooling water connection needed. | whole series |
| Inlet and outlet connections are DN 100 ISO-F or DN 100 PN 16 flanges. p.2 ↗ | Piping must match DN 100; choose ISO-F for vacuum lines or PN 16 for pressure-rated flanging. | whole series |
| Sound pressure level per EN ISO 2151 at 1 hPa inlet pressure: 67 dB(A) (1004), 68 dB(A) (1304), 69 dB(A) (2104). p.3 ↗ | Noise is comparable across models; below typical 80 dB(A) action threshold, but enclosure may still be needed for multiple units. | HiLobe 1004, 1304, 2104 |
| I/O interfaces are PV.can and RS485; a Profinet converter and OmniControl are available as options. p.1 ↗ | Integrate condition monitoring/remote control via RS485 or PV.can; add Profinet converter for modern PLC networks. | whole series |
| Extension cable package allows up to 30 m between pump and drive electronics. p.1 ↗ | Drive unit can be located remotely (e.g. in a switch cabinet) up to 30 m away; cable length must not exceed 30 m. | whole series |
| Weight is approx. 115 kg and dimensions 875 x 282 x 240 mm for all three models. p.3 ↗ | Two-person lift or hoist for installation; mounting frames must support ~115 kg on a 875 x 282 footprint. | whole series |