HiLobe 2703 — product leaflet 6203 global
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiLobe series Roots-type vacuum boosters, covering three models: HiLobe 2703 (890-2700 m³/h), HiLobe 4503 (890-4500 m³/h) and HiLobe 6203 (890-6200 m³/h). All share the same envelope dimensions, DN160 ISO-F / DN150 PN16 flanges, IE5 canned-motor design without shaft seals, water cooling and electronic drive unit RC 7500. Options/accessories include Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance), inlet/exhaust temperature and pressure monitoring, extension cable package up to 30 m, OmniControl, operating fluids and various electronic drive options (box version, switch-cabinet mounting plate, without drive electronics).
Section-by-Section Technical Breakdown
The HiLobe 2703-6203 is a series of vacuum boosters emphasizing reliability, performance and efficiency. Condition monitoring is done via integrated sensors, and the hermetically sealed IE5 synchronous canned-motor design eliminates shaft seals. Optimized rotor geometries and variable speed drive contribute to a high performance-to-size ratio and extended maintenance intervals.
- High up-time due to intelligent condition monitoring via integrated sensors
- High pumping speed with best performance-to-size-ratio
- Hermetically sealed IE5 synchronous motor, canned motor design, no shaft seals
- Variable speed drive and optimized rotor geometries
- Extended maintenance intervals
A range of accessories and drive options can be ordered for the HiLobe boosters, covering communication, monitoring and mechanical protection functions. Electronic drive electronics can be supplied as a box version, as a mounting plate for switch-cabinet integration, or omitted entirely.
- Profinet converter
- Barrier gas kit (plastic or stainless steel)
- Gear chamber evacuation
- Flushing device (spray lance)
- Temperature and pressure monitoring (inlet and exhaust side)
- Extension cable package (possible up to 30 m)
- OmniControl
- Operating fluids
- Electronic drive options: box version, mounting plate for switch cabinet integration, without drive electronics
This section tabulates pumping speed ranges, rotational speed ranges and maximum differential pressures for the three models, along with main/secondary flange types, input voltage, motor data and electronic drive unit. All models use DN 160 ISO-F / DN 150 PN16 flanges on both inlet and exhaust, PTC motor protection and the RC 7500 drive unit.
- Nominal pumping speed: 2703: 890-2700 m³/h; 4503: 890-4500 m³/h; 6203: 890-6200 m³/h
- Rotational speed: 2703: 1500-4500 rpm; 4503: 1500-7500 rpm; 6203: 1500-10500 rpm
- Max differential pressure at max. rotational speed: 54 hPa (2703), 36 hPa (4503), 21 hPa (6203); at min. rotational speed 65 hPa for all models
- Flanges (main and secondary): DN 160 ISO-F or DN 150 PN 16
- Input voltage: 380-480 V AC (±10%), 50/60 Hz
- Motor: three-phase with PTC protection; rated power 3.5 kW (2703), 5.5 kW (4503), 7.5 kW (6203)
- Electronic drive unit: RC 7500; recommended mains fuse 25 A
- I/O interfaces: PV.can and RS485; cooling: water cooling; ambient temperature 5-40 °C
Identical physical and operational limits apply to all three models, including shipping/ambient temperatures, noise level, operating fluid, protection rating, cooling water requirements and leak rate. All units share the same footprint (860 x 428 x 354 mm) and weight of approx. 258 kg.
- Shipping temperature: -10 to 40 °C
- Sound pressure level (EN ISO 2151) at inlet pressure 1 hPa: 60 dB(A)
- Operating fluid: D2, filling volume 1 l
- Protection degree: IP54, type 12
- Cooling water: pressure 2000-6000 hPa, flow 120-360 l/h, temperature 5-35 °C
- Integral leak rate: 1E-06 Pa m³/s
- Dimensions (L x W x H): 860 x 428 x 354 mm; weight approx. 258 kg
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max. differential pressure drops with increasing rotational speed: 54 hPa (HiLobe 2703), 36 hPa (4503), 21 hPa (6203) at max. rpm, vs. 65 hPa for all models at min. rotational speed. p.2 ↗ | When backing by a fore-vacuum pump, the drive speed must be reduced or a larger booster chosen if high pressure differentials are expected at high rpm; speed/differential pressure must be coordinated in control logic. | HiLobe 2703, 4503, 6203 |
| Rotational speed ranges differ strongly: 1500-4500 rpm (2703), 1500-7500 rpm (4503), 1500-10500 rpm (6203). p.2 ↗ | Model selection for pumping speed up to 6200 m³/h is achieved via higher rotor speeds on the same 860 x 428 x 354 mm envelope; drive electronics must support the applicable speed range. | whole series |
| Flange connections are DN 160 ISO-F or DN 150 PN 16 on both main (inlet) and secondary (exhaust) sides for all models. p.2 ↗ | Piping and mating flange hardware can be standardized across all three models; ISO-F for vacuum duty or PN16 pressure-rated flanges for higher-pressure operation. | whole series |
| Supply voltage is 380-480 V AC (±10%), 50/60 Hz; recommended mains fuse capacity is 25 A. p.2 ↗ | Standard industrial three-phase supply suffices; fusing and cabling should be dimensioned for 25 A. | whole series |
| Rated motor power at full rotational speed: 3.5 kW (2703), 5.5 kW (4503), 7.5 kW (6203). p.2 ↗ | Drive and electrical infrastructure must be sized per model; power draw rises with speed range despite identical physical size. | HiLobe 2703 / 4503 / 6203 respectively |
| Motor is a hermetically sealed IE5 synchronous three-phase canned motor without shaft seals, protected via PTC. p.1 ↗ | No shaft-seal leakage path into the process and no seal maintenance; PTC sensors must be wired into the drive/motor protection circuit. | whole series |
| Electronic drive unit is the RC 7500 for all models; interfaces are PV.can and RS485; a Profinet converter is available as an option. p.1 ↗ | Integration into PLC/SCADA is via RS485 or PV.can as standard; specify the Profinet converter if the plant network is Profinet. | whole series |
| Cooling is water-based with required pressure 2000-6000 hPa, flow 120-360 l/h, and water temperature 5-35 °C. p.2 ↗ | A closed water circuit within these limits must be provided and interlocked before operation; inadequate flow/temperature will cause overheating. | whole series |
| Ambient temperature range is 5-40 °C; shipping temperature range is -10 to 40 °C. p.2 ↗ | Installation locations must stay above 5 °C to avoid operating outside specification; storage/transport below -10 °C is not permitted. | whole series |
| Operating fluid is D2 with a filling volume of 1 l for all models. p.3 ↗ | Gear lubrication is common across models, simplifying spare-fluid stock; only Pfeiffer D2 should be used for topping up or oil changes. | whole series |
| Sound pressure level is 60 dB(A) (EN ISO 2151) at inlet pressure 1 hPa for all models. p.3 ↗ | Low noise permits installation near work areas without special acoustic measures at typical booster operating pressures. | whole series |
| Protection degree is IP54 / type 12. p.3 ↗ | Suitable for indoor industrial environments with dust and dripping water protection; not for wash-down or outdoor installation without additional protection. | whole series |
| Integral leak rate is 1E-06 Pa m³/s. p.3 ↗ | Tightness is sufficient for high-vacuum systems; this value should be used as acceptance criterion for leak-checking after installation or maintenance. | whole series |
| All three models share identical dimensions (860 x 428 x 354 mm) and weight (approx. 258 kg). p.3 ↗ | Mounting frames, lifting gear and footprint planning are identical across the model range; ~258 kg requires appropriate lifting equipment. | whole series |
| Extension cable package allows sensor/monitoring cable extension up to 30 m. p.1 ↗ | Drive electronics can be located up to 30 m away from the pump when the extension cable package option is used. | whole series (option) |
| Optional inlet and exhaust side temperature and pressure monitoring, barrier gas kit (plastic or stainless steel), gear chamber evacuation and spray-lance flushing device are available. p.1 ↗ | These options should be specified for demanding processes (condensable/contaminating media, high protection requirements) at ordering time since they affect monitoring and flushing capability. | whole series (options) |