HiLobe 2704 — product leaflet hilobe 2704 6204 global
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiLobe series vacuum boosters (Roots pumps) datasheet covering three models: HiLobe 2704, HiLobe 4504, HiLobe 6204. Includes technical specifications table, dimensional drawing/pumping speed curves, and accessory/option list (Profinet Converter, barrier gas kit, gear chamber evacuation, flushing device, monitoring, extension cables up to 30 m, OmniControl, electronic drive options with RC 7500 drive unit).
Section-by-Section Technical Breakdown
Highlights the HiLobe booster design: integrated sensor condition monitoring for high up-time, high pumping speed with best performance-to-size ratio, and efficiency via hermetically sealed IE5 canned-motor design without shaft seals. Lists available accessories and drive options.
- Intelligent condition monitoring via integrated sensors
- Hermetically sealed synchronous motor (IE5), canned motor design, no shaft seals
- Variable speed drive, optimized rotor geometries, extended maintenance intervals
- Options: Profinet Converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance)
- Temperature and pressure monitoring (inlet and exhaust side); extension cable package possible up to 30 m
- OmniControl, operating fluids, electronic drive options: box version, mounting plate for switch cabinet integration, or without drive electronics
Tabulated performance, electrical and interface data for all three models. Includes pumping speed ranges, speed ranges, differential pressure limits, flanges, motor and drive data, cooling, and ambient limits. All models share identical flanges, input voltage, drive unit, weight and dimensions.
- Nominal pumping speed: 2704: 890–2700 m³/h; 4504: 890–4440 m³/h; 6204: 890–6220 m³/h
- Rotational speed: 2704: 1500–4500 rpm; 4504: 1500–7500 rpm; 6204: 1500–10500 rpm
- Max. differential pressure at max speed: 35 hPa (2704), 17 hPa (4504), 10 hPa (6204); at min speed: 50 hPa (all)
- Main and secondary flanges (all models): DN 160 ISO-F or DN 150 PN 16
- Input voltage: 380–480 V AC (±10), 50/60 Hz; three-phase motor with PTC protection
- Rated power at full speed: 3.5 kW (2704), 5.5 kW (4504), 7.5 kW (6204)
- Electronic drive unit: RC 7500; recommended mains fuse 25 A; I/O: PV.can, RS485
- Active air cooling; ambient temperature 5–40 °C
- Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 62 dB(A) (2704), 65 dB(A) (4504/6204)
Shipping/temperature limits, operating fluid, leak tightness, dimensions and weight. All three models share the same operating fluid, fill volume, enclosure rating, leak rate, footprint and mass, simplifying installation planning.
- Shipping temperature: -10 to 40 °C (all models)
- Operating fluid: D2, filling volume 3.2 l (all models)
- Protection degree: IP54; type 12
- Integral leak rate: 1E-06 Pa m³/s
- Dimensions (L x W x H): 1122 x 430 x 354 mm; weight approx. 280 kg (all models)
Page 2 contains a dimensional drawing and pumping speed curves plotted for 50 Hz and 60 Hz operation. The curves allow selection of effective pumping speed versus inlet pressure for each model within the specified speed ranges.
- Dimensional drawing provided on page 2
- Pumping speed curves given for 50 Hz (solid) and 60 Hz (dashed) operation
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max differential pressure at maximum rotational speed differs strongly by model: 35 hPa (2704), 17 hPa (4504), 10 hPa (6204); at minimum speed all models allow 50 hPa. p.2 ↗ | For high pressure differential duty, operate at reduced speed or select the 2704; the 6204 must only see ≤10 hPa ΔP at full 10500 rpm. | whole series, model-specific values |
| Rotational speed ranges: 1500–4500 rpm (2704), 1500–7500 rpm (4504), 1500–10500 rpm (6204). p.2 ↗ | Drive/speed ramp settings and backing pump matching must respect model-specific speed ceilings; higher-speed models deliver more pumping speed but tolerate less ΔP at max speed. | whole series |
| Nominal pumping speed spans 890–2700 m³/h (2704), 890–4440 m³/h (4504), 890–6220 m³/h (6204). p.2 ↗ | All three fit the same 1122 x 430 x 354 mm envelope, so throughput can be scaled by model choice without changing the installation footprint. | whole series |
| Main and secondary flanges are DN 160 ISO-F or DN 150 PN 16 on all models. p.2 ↗ | Inlet and exhaust piping is identical across the series; choose ISO-F for vacuum duty or PN 16 for pressure-side/robust connections. | whole series |
| Input voltage is 380–480 V AC (±10%), 50/60 Hz with a recommended 25 A mains fuse. p.2 ↗ | Supply wiring and breaker sizing must be planned for 25 A per pump on a 400–480 V three-phase network. | whole series |
| Rated power at full rotational speed: 3.5 kW (2704), 5.5 kW (4504), 7.5 kW (6204). p.2 ↗ | Motor/drive sizing and energy budgeting per model; all use the same RC 7500 electronic drive unit. | whole series |
| Drive electronics is the RC 7500; interfaces are PV.can and RS485. p.1 ↗ | Control integration must use PV.can or RS485; a Profinet Converter accessory is required for Profinet networks. | whole series |
| Motor is a hermetically sealed IE5 synchronous canned motor with no shaft seals and PTC motor protection. p.1 ↗ | No shaft seal maintenance/replacement and very low drive losses; PTC trip signal must be wired into the protection chain. | whole series |
| Integral leak rate is 1E-06 Pa m³/s. p.3 ↗ | Suitable as booster stage in high-vacuum systems; system leak-up calculations can assume this per-unit leak rate. | whole series |
| Operating fluid is D2 with a fill volume of 3.2 l. p.3 ↗ | Stock D2 oil for commissioning and oil changes; 3.2 l per fill per pump. | whole series |
| Ambient temperature range is 5–40 °C; shipping/storage temperature -10–40 °C. p.2 ↗ | Installation site must be climate-controlled; protect units from freezing during transport/storage. | whole series |
| Protection degree IP54 / type 12, active air cooling. p.2 ↗ | Suitable for dust-protected industrial cabinets areas; ensure unobstructed airflow for the active air cooling, no water cooling needed. | whole series |
| Sound pressure level per EN ISO 2151 at 1 hPa inlet pressure: 62 dB(A) for 2704, 65 dB(A) for 4504/6204. p.3 ↗ | Noise load calculation for workplace safety; lower inlet pressures/speeds typically reduce noise further. | whole series, model-specific values |
| Weight is approx. 280 kg with dimensions 1122 x 430 x 354 mm (L x W x H) for all models. p.3 ↗ | Lifting gear rated ≥300 kg and mounting frame design identical across the series. | whole series |
| Extension cable package allows drive/pump separation up to 30 m. p.1 ↗ | Remote drive electronics installation possible; cable runs beyond 30 m not supported. | whole series |
| Optional barrier gas kit (plastic or stainless steel), gear chamber evacuation and spray-lance flushing device are available. p.1 ↗ | For dusty/condensable processes, specify barrier gas and flushing options at ordering time to protect the gear chamber and rotors. | whole series |