Induztr
Engineering Digest Document Viewer Related Models

HiLobe 11003 — product leaflet hilobe 8103 14003 global

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiLobe series three-lobe vacuum boosters datasheet covering three models: HiLobe 8103, HiLobe 11003 and HiLobe 14003, all driven by the RC 15000 electronic drive unit. Accessories/options listed: Profinet converter, barrier gas kit (plastic/stainless steel), gear chamber evacuation, spray-lance flushing device, temperature/pressure monitoring (inlet and exhaust), extension cable package up to 30 m, OmniControl, operating fluids, and electronic drive options (box version, switch-cabinet mounting plate, without drive electronics).

Section-by-Section Technical Breakdown

pp. 1
Product Features, Accessories and Options

The HiLobe vacuum boosters are positioned as reliable, high-performance, efficient roots-type boosters. Key design points are intelligent condition monitoring via integrated sensors, hermetically sealed IE4 canned-motor design without shaft seals, variable speed drive, optimized rotor geometry and extended maintenance intervals. A list of optional accessories and drive configurations is given.

  • High up-time due to intelligent condition monitoring via integrated sensors
  • Hermetically sealed synchronous motor (IE4), canned motor design, no shaft seals
  • Variable speed drive and optimized rotor geometries; extended maintenance intervals
  • Options: Profinet converter; barrier gas kit (plastic or stainless steel); gear chamber evacuation; flushing device (spray lance); temperature and pressure monitoring (inlet and exhaust side)
  • Extension cable package possible up to 30 m; OmniControl; operating fluids
  • Electronic drive options: box version, mounting plate for switch cabinet integration, or without drive electronics
pp. 2
Performance and Electrical Data (Dimensional Drawing, Pumping Speed)

This section provides the dimensional drawing, pumping speed curves for 50/60 Hz, and a comparison table of the three models. Nominal pumping speeds range from 2700 to 13540 m³/h depending on model and speed, with differential pressure limits decreasing at higher speeds. All models share the same DN 250 flanges, water cooling, and RC 15000 electronic drive.

  • Nominal pumping speed: 8103: 2700-8120 m³/h; 11003: 2700-10830 m³/h; 14003: 2700-13540 m³/h
  • Rotational speed: 8103: 1500-4500 rpm; 11003: 1500-6000 rpm; 14003: 1500-7500 rpm
  • Max. differential pressure at max. rotational speed: 25 hPa (8103), 20 hPa (11003), 10 hPa (14003); at min. rotational speed: 30 hPa all models
  • Main and secondary flanges: DN 250 ISO-F | DN 250 PN 16 (all models)
  • Input voltage: 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
  • Rated power at full rotational speed: 9 kW (8103), 12 kW (11003), 15 kW (14003)
  • Electronic drive unit: RC 15000; recommended mains fuse 50 A; interfaces PV.can and RS485
  • Cooling: water cooled; ambient temperature 5-40 °C
pp. 3
Operating, Cooling and Physical Data

This table lists operating environment limits, cooling water requirements, noise level, operating fluid, leak rate, dimensions and weight. All three models share identical values for these parameters.

  • Shipping temperature: -10 to 40 °C; sound pressure level 70 dB(A) (EN ISO 2151) at 1 hPa inlet pressure
  • Operating fluid: D2, filling volume 3 l
  • Protection degree: IP54; type 12
  • Cooling water: pressure 2000-6000 hPa, flow 120-360 l/h, temperature 5-35 °C
  • Integral leak rate: 1E-06 Pa m³/s
  • Dimensions (L x W x H): 1115 x 583 x 468 mm; weight approx. 620 kg (all models)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Max. differential pressure at maximum rotational speed is 25 hPa (HiLobe 8103), 20 hPa (11003) and 10 hPa (14003); at minimum rotational speed all models tolerate 30 hPa. p.2 ↗ Pressure differential limits depend on speed: when staging the booster with a backing pump, the drive speed must be reduced or the backing pump sized so the differential across the booster stays within limits at high speeds. whole series (values differ per model)
Rotational speed ranges: 8103: 1500-4500 rpm, 11003: 1500-6000 rpm, 14003: 1500-7500 rpm. p.2 ↗ The higher-speed 14003 achieves the largest pumping speed but with the lowest allowed differential pressure; selection must trade speed headroom against differential tolerance. whole series
All models use the RC 15000 electronic drive unit with a recommended 50 A mains fuse. p.2 ↗ Specify RC 15000 drive and 50 A fuse in the supply-side electrical design regardless of model chosen. whole series
Input voltage is 380-480 V AC ±10%, 50/60 Hz, three-phase motor with PTC motor protection. p.2 ↗ Suitable for standard 400/480 V industrial networks; PTC sensors must be wired into the motor protection circuit. whole series
Rated power at full rotational speed: 9 kW (8103), 12 kW (11003), 15 kW (14003). p.2 ↗ Sizes the motor supply cable, breaker and drive electronics per model. whole series
Cooling is water-based: pressure 2000-6000 hPa, flow 120-360 l/h, water temperature 5-35 °C. p.3 ↗ A closed-loop or facility water circuit meeting these flow/pressure/temperature limits is required at installation. whole series
Ambient temperature range is 5-40 °C (operation) and -10 to 40 °C for shipping. p.2 ↗ Do not install or transport the pump outside these limits; freeze protection needed below 5 °C in operation. whole series
Main and secondary flanges are DN 250 ISO-F or DN 250 PN 16 on all models. p.2 ↗ Inlet/outlet connections are identical across models; pipework and gaskets can be standardized, with a choice of clamped ISO-F or PN16 flange mounting. whole series
Integral leak rate is 1E-06 Pa m³/s. p.3 ↗ Tightness is sufficient for high-vacuum applications; leak-up rate of the chamber can be budgeted with this value in mind. whole series
Operating fluid is D2 with a filling volume of 3 l. p.3 ↗ Stock Pfeiffer D2 fluid for oil changes; 3 l per pump for oil service planning. whole series
Protection degree IP54, type 12. p.3 ↗ Suitable for indoor industrial environments with dust and dripping-water protection; not for wash-down or outdoor use without additional enclosures. whole series
Sound pressure level is 70 dB(A) (EN ISO 2151) at 1 hPa inlet pressure. p.3 ↗ Noise is moderate and identical for all models; standard hearing-protection zoning likely sufficient. whole series
Dimensions 1115 x 583 x 468 mm (L x W x H) and weight approx. 620 kg for all models. p.3 ↗ Lifting gear rated for >620 kg and identical foundation/footprint can be used for any variant; models are physically interchangeable. whole series
I/O interfaces are PV.can and RS485; a Profinet converter is available as an option. p.1 ↗ Remote monitoring/condition monitoring integration via RS485 or PV.can; Profinet integration requires the optional converter. whole series
Extension cable package allows drive-motor separation up to 30 m. p.1 ↗ Pump can be located up to 30 m from drive electronics; longer distances need a different solution. whole series
Drive electronics options: box version, mounting plate for switch cabinet integration, or without drive electronics. p.1 ↗ Enables either decentralized installation next to the pump or central integration into an existing switch cabinet. whole series
Canned-motor design is hermetically sealed with no shaft seals, IE4 synchronous motor. p.1 ↗ Eliminates a common leak/wear path (shaft seals), reducing maintenance and improving containment in process applications. whole series
Barrier gas kit (plastic or stainless steel), gear chamber evacuation and spray-lance flushing are available options. p.1 ↗ For dusty/condensable processes, specify barrier gas, flushing or gear evacuation at ordering time since these are factory options. whole series