Pfeiffer Vacuum HiLobe series vacuum boosters (Roots-type), covering three models: HiLobe 8104, HiLobe 11004, HiLobe 14004 (title references 8104-14004). All share identical dimensions, weight, flanges and drive electronics (RC 15000); they differ mainly in max rotational speed, pumping speed and rated power. Accessories/options include Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance), temperature/pressure monitoring (inlet/exhaust), extension cable package up to 30 m, OmniControl, operating fluids, and electronic drive options (box version, switch-cabinet mounting plate, or without drive electronics).
Section-by-Section Technical Breakdown
Highlights the HiLobe vacuum booster's key selling points: reliability through intelligent condition monitoring via integrated sensors, high pumping speed with best performance-to-size ratio, and efficiency from a hermetically sealed IE4 canned-motor design with variable speed drive and no shaft seals. Also lists available accessories, spare parts and options.
- Intelligent condition monitoring via integrated sensors for high up-time
- Hermetically sealed synchronous motor (IE4), canned motor design, no shaft seals
- Variable speed drive and optimized rotor geometries
- Extended maintenance intervals
- Options: Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance)
- Temperature and pressure monitoring (inlet and exhaust side)
- Extension cable package possible up to 30 m
- OmniControl, operating fluids, electronic drive options: box version, mounting plate for switch cabinet integration, or without drive electronics
Tabulated technical data for HiLobe 8104, 11004 and 14004 covering pumping speed, speed range, differential pressure limits, flanges, electrical data, cooling, interfaces, environmental limits, noise, operating fluid, leak rate, dimensions and weight.
- Nominal pumping speed: 2700-8120 m³/h (8104), 2700-10830 m³/h (11004), 2700-13540 m³/h (14004)
- Rotational speed: 1500-4500 rpm (8104), 1500-6000 rpm (11004), 1500-7500 rpm (14004)
- Max differential pressure at max speed: 25 / 20 / 10 hPa; at min speed: 30 hPa for all models
- Main and secondary flanges: DN 250 ISO-F | DN 250 PN 16 (all models)
- Input voltage: 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
- Rated power at full speed: 9 kW (8104), 12 kW (11004), 15 kW (14004)
- Electronic drive unit: RC 15000; recommended mains fuse 50 A; I/O interfaces PV.can and RS485
- Active air cooling; ambient temperature 5-40 °C; shipping temperature -10-40 °C
- Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 75 dB(A) all models
- Operating fluid D2, filling 5.2 l; protection degree IP54 / type 12
- Integral leak rate 1E-06 Pa·m³/s; dimensions 1433 x 583 x 468 mm; weight approx. 670 kg
Page 2 provides a dimensional drawing and pumping speed curves for 50 Hz and 60 Hz operation, referenced to the tabulated data for the three models.
- Dimensional drawing for the HiLobe series
- Pumping speed curves shown for 50 Hz (solid) and 60 Hz (dotted) operation
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max differential pressure at maximum rotational speed is 25 hPa (8104), 20 hPa (11004) and 10 hPa (14004); at minimum speed it is 30 hPa for all models. p.2 ↗ | The faster the model/operating speed, the lower the permissible differential pressure — size the backing pump/pressure management accordingly, especially at high speeds with the 14004. | Whole series (per model values) |
| Pumping speed ranges: 2700-8120 m³/h (8104, 1500-4500 rpm), 2700-10830 m³/h (11004, 1500-6000 rpm), 2700-13540 m³/h (14004, 1500-7500 rpm). p.2 ↗ | Select the model based on required speed at the operating speed; higher-speed variants deliver more throughput but accept less differential pressure. | Whole series |
| Input voltage is 380-480 V AC (±10%), 50/60 Hz, three-phase motor with PTC motor protection; recommended mains fuse capacity is 50 A. p.2 ↗ | Supply wiring, breakers and fusing must be dimensioned for 380-480 V AC and 50 A fuse rating; PTC sensors must be wired into the motor protection circuit. | Whole series |
| Rated power at full rotational speed: 9 kW (8104), 12 kW (11004), 15 kW (14004), using an IE4 synchronous canned motor (hermetically sealed, no shaft seals). p.1 ↗ | Drive electronics must match the rated power; canned motor means no shaft-seal maintenance but drive integration (RC 15000) is required. | Whole series (per model) |
| Electronic drive unit is RC 15000; available options: box version, mounting plate for switch cabinet integration, or without drive electronics. p.1 ↗ | Plan switch cabinet space or a separate enclosure for the RC 15000 depending on the chosen option. | Whole series |
| I/O interfaces: PV.can and RS485; optional Profinet converter available. p.1 ↗ | For Profinet-based plant control, the Profinet converter accessory must be ordered; otherwise use PV.can/RS485. | Whole series |
| Main and secondary flanges are DN 250 ISO-F | DN 250 PN 16 on all models. p.2 ↗ | Piping and connecting components must be DN 250 ISO-F (vacuum side) or DN 250 PN 16 (pressure-rated) compatible; identical for all three models. | Whole series |
| Integral leak rate is 1E-06 Pa·m³/s; protection degree IP54 / type 12. p.2 ↗ | Suitable for high-vacuum integrity applications; enclosure must be indoors/dry given IP54/type 12 rating. | Whole series |
| Ambient temperature range 5-40 °C, shipping temperature -10-40 °C, active air cooling. p.2 ↗ | Installation site must stay within 5-40 °C with free air access for cooling; storage/transport outside -10-40 °C requires precautions. | Whole series |
| Operating fluid is D2 with a filling volume of 5.2 l for all models. p.3 ↗ | Stock Pfeiffer D2 operating fluid for commissioning and oil changes; 5.2 l per pump per change. | Whole series |
| Dimensions 1433 x 583 x 468 mm (L x W x H) and weight approx. 670 kg for all models. p.3 ↗ | Foundation, lifting gear and skid design must handle ~670 kg; identical footprint simplifies interchangeability between models. | Whole series |
| Sound pressure level 75 dB(A) (EN ISO 2151) at 1 hPa inlet pressure for all models. p.3 ↗ | Noise is uniform across the series; standard workplace noise measures generally sufficient. | Whole series |
| Condition monitoring via integrated sensors (temperature and pressure monitoring on inlet and exhaust side available as option). p.1 ↗ | Enables predictive maintenance; monitor outputs via PV.can/RS485 or integrate OmniControl. | Whole series (optional monitoring package) |
| Extension cable package possible up to 30 m between pump and drive electronics. p.1 ↗ | Drive unit can be placed up to 30 m from the pump if the extension cable package is used — useful for noise/vibration isolation or cabinet placement. | Whole series |
| Barrier gas kit (plastic or stainless steel), gear chamber evacuation and flushing device (spray lance) are available options. p.1 ↗ | Select barrier gas kit material per process compatibility; gear chamber evacuation/flushing for processes with condensable or particulate contamination. | Whole series |