COBRA BC 0101 G — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Single model datasheet: Busch COBRA BC 0101 G dry screw vacuum pump. No variants or ordering codes are given.
Section-by-Section Technical Breakdown
pp. 1
Product Overview
The COBRA BC 0101 G is a dry screw vacuum pump aimed at semiconductor-type applications. It uses an advanced screw design with patented self-balancing screws in a bell-shaped construction. The document highlights high performance, efficiency via a variable speed drive, and a compact fit-in-place design.
- Advanced screw design, bell-shaped construction, patented self-balancing screws
- Suited for load lock and transfer chambers, metrology, lithography, PVD and rapid thermal annealing
- Intelligent variable speed drive, minimal maintenance, high uptime, direct water cooling
- Directly mounted canned motor and integrated control panel
pp. 2
Technical Data and Dimensions
The datasheet lists nominal pumping speed, ultimate pressure, motor data, noise, cooling water demand, weight, and connection sizes for the COBRA BC 0101 G. A dimensional drawing and a pumping speed curve (air at 20°C, tolerance ±10%) are referenced.
- Nominal pumping speed 90 m³/h
- Ultimate pressure 0.01 hPa (mbar)
- Nominal motor rating 1.5 kW; power consumption at ultimate pressure 0.7 kW
- Nominal motor speed 3000 min⁻¹
- Sound pressure level 58 dB(A) (ISO 2151, KpA = 3 dB)
- Water consumption 1.0 l/min; weight approx. 115 kg
- Dimensions 520 x 300 x 340 mm (L x W x H)
- Gas inlet/outlet DN 50 KF / DN 40 KF
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Pumping medium data is specified for air at 20°C with a tolerance of ±10% p.2 ↗ | Use the ±10% tolerance band when sizing pump-down times or conductance calculations | COBRA BC 0101 G |
| Nominal pumping speed is 90 m³/h p.2 ↗ | Basis for conductance and pump-down calculations at line pressure | COBRA BC 0101 G |
| Ultimate pressure is 0.01 hPa (mbar) p.2 ↗ | Suitable for high-vacuum load lock applications down to 1e-2 mbar; do not expect lower base pressure without a secondary pump | COBRA BC 0101 G |
| Nominal motor rating is 1.5 kW with power consumption of only 0.7 kW at ultimate pressure p.2 ↗ | Electrical supply sizing can be based on 1.5 kW peak; steady-state load at base pressure is roughly half | COBRA BC 0101 G |
| Nominal motor speed is 3000 min⁻¹ p.2 ↗ | Use for coupling/drive calculations and vibration considerations | COBRA BC 0101 G |
| Sound pressure level is 58 dB(A) per ISO 2151 with KpA = 3 dB p.2 ↗ | Low noise installation possible; allow ±3 dB uncertainty in workplace noise assessments | COBRA BC 0101 G |
| Cooling water consumption is 1.0 l/min (direct water cooling) p.2 ↗ | Provide a chilled/recirculating water supply of at least 1 l/min; no air cooling option indicated | COBRA BC 0101 G |
| Weight is approximately 115 kg p.2 ↗ | Specify lifting equipment and mounting frames rated above 115 kg | COBRA BC 0101 G |
| Dimensions are 520 x 300 x 340 mm (L x W x H) p.2 ↗ | Compact footprint enables fit-in-place installation in tight tool/chamber layouts | COBRA BC 0101 G |
| Gas inlet is DN 50 KF and outlet is DN 40 KF p.2 ↗ | Select matching KF flange hardware and ensure outlet line conductance does not throttle the 90 m³/h pumping speed | COBRA BC 0101 G |
| Pump uses a directly mounted canned motor with integrated control panel and intelligent variable speed drive p.1 ↗ | No separate drive/coupling alignment is needed; integration requires interfacing with the onboard controller rather than an external VFD | COBRA BC 0101 G |
| Pump is oil-free (dry screw) with direct water cooling p.1 ↗ | No lubricant management in the pumped volume; hydrocarbon-free operation suitable for semiconductor processes (lithography, PVD, RTA) | COBRA BC 0101 G |