TORRI BD 0100 A — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum TORRI BD series multi-stage Roots vacuum pumps, covering three variants: TORRI BD 0100 A (100 m³/h), TORRI BD 0300 A (300 m³/h) and TORRI BD 0600 A (600 m³/h). The two larger models operate as combinations of a backing pump plus a vacuum booster stage. Data sheet dated 01.07.2025, 2 pages.
Section-by-Section Technical Breakdown
The document introduces the TORRI BD 0100–0600 A series of multi-stage Roots vacuum pumps with three headline characteristics: flexible (shortest pump-down time for load lock chambers), efficient (extremely low energy consumption, minimal maintenance, high uptime), and compact (exceptionally small and lightweight).
- Positioned for fast pump-down of load lock chambers
- Low energy consumption and minimal maintenance claimed
- Compact and lightweight construction highlighted
Page 2 provides a dimensional drawing, pumping speed curves (air at 20 °C, ±10 % tolerance) and a full technical data table comparing the three models. All models share a 2.2 kW nominal motor rating for the backing pump, <55 dB(A) noise level, and DN 25 KF outlet; the larger models add a booster motor stage.
- Nominal pumping speed: 100 / 300 / 600 m³/h for BD 0100 / 0300 / 0600 A
- Ultimate pressure: 0.01 hPa (BD 0100 A), 0.001 hPa (BD 0300 A and BD 0600 A)
- Nominal motor rating backing pump: 2.2 kW (all models); vacuum booster: 2.2 kW (BD 0300 A, BD 0600 A)
- Nominal motor speeds: backing pump 5500 min⁻¹ (all); booster 3500 min⁻¹ (BD 0300 A), 7000 min⁻¹ (BD 0600 A)
- Power consumption at ultimate pressure: 0.4 / 0.5 / 0.6 kW
- Noise level (ISO 2151): <55 dB(A) for all models
- Water consumption: 1.0 l/min (BD 0100 A), 2.0 l/min (BD 0300 A, BD 0600 A)
- Weight approx.: 60 kg (BD 0100 A), 125 kg (BD 0300 A, BD 0600 A)
- Dimensions L×W×H: 450×230×275 mm (BD 0100 A); 530×230×520 mm (BD 0300/0600 A)
- Gas inlet / outlet: DN 50 KF / DN 25 KF (BD 0100 A); DN 80 KF / DN 25 KF (BD 0300 A, BD 0600 A)
- Pumping speed curves valid for air at 20 °C with ±10 % tolerance
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Nominal pumping speeds are 100 m³/h (BD 0100 A), 300 m³/h (BD 0300 A) and 600 m³/h (BD 0600 A). p.2 ↗ | Model selection for pump-down time calculations must match the load lock chamber volume to one of these three discrete speed classes. | whole series |
| Ultimate pressure is 0.01 hPa for TORRI BD 0100 A and 0.001 hPa for BD 0300 A and BD 0600 A. p.2 ↗ | Processes requiring pressures below 0.01 hPa must use the 0300 A or 0600 A variant; the smallest model cannot reach them. | BD 0100 A vs BD 0300 A / BD 0600 A |
| Backing pump motor rating is 2.2 kW at 5500 min⁻¹ on all three models. p.2 ↗ | Electrical supply sizing can be standardized at 2.2 kW for the backing pump stage across the whole series. | whole series |
| BD 0300 A and BD 0600 A include an additional 2.2 kW vacuum booster motor; booster speed is 3500 min⁻¹ (BD 0300 A) or 7000 min⁻¹ (BD 0600 A). p.2 ↗ | The larger models need supply capacity for two motors (total nominal 4.4 kW); drive speed differs per model, relevant for spare parts and service. | BD 0300 A, BD 0600 A |
| Power consumption at ultimate pressure is only 0.4 kW (BD 0100 A), 0.5 kW (BD 0300 A) and 0.6 kW (BD 0600 A). p.2 ↗ | Very low holding-power draw enables energy-efficient operation at base pressure; supports the 'efficient' positioning for load lock cycling applications. | whole series |
| Noise level is <55 dB(A) per ISO 2151 for all models. p.2 ↗ | Pumps can be placed in laboratory or operator-adjacent environments without additional acoustic enclosures in most cases. | whole series |
| Cooling water consumption is 1.0 l/min for BD 0100 A and 2.0 l/min for BD 0300 A and BD 0600 A. p.2 ↗ | Facility cooling water supply and plumbing must be dimensioned accordingly; the two larger models double the water demand of the smallest. | whole series |
| Weights are approx. 60 kg (BD 0100 A) and 125 kg (BD 0300 A and BD 0600 A). p.2 ↗ | The small model is manually installable; the larger models require lifting equipment or two-person handling and adequate mounting structures. | BD 0100 A vs BD 0300 A / BD 0600 A |
| Footprint dimensions are 450×230×275 mm (L×W×H) for BD 0100 A and 530×230×520 mm for BD 0300 A / BD 0600 A. p.2 ↗ | The series fits compact load lock skids; clearance planning can rely on the dimensional drawing on p.2. | whole series |
| Gas connections: BD 0100 A has DN 50 KF inlet / DN 25 KF outlet; BD 0300 A and BD 0600 A have DN 80 KF inlet / DN 25 KF outlet. p.2 ↗ | Vacuum plumbing and KF clamping hardware must be selected per model; note the outlet is only DN 25 KF even on the 600 m³/h unit, constraining fore-line sizing. | whole series |
| Pumping speed data is specified for air at 20 °C with a tolerance of ±10 %. p.2 ↗ | System-level pump-down calculations should include a 10 % margin, and different gases or temperatures will shift the actual curves. | whole series |
| BD 0100 A is a single backing-pump configuration (no booster motor listed), while the 0300 A and 0600 A are two-stage backing-pump-plus-booster combinations. p.2 ↗ | Architecture differs within the series: only the two larger variants provide the booster compression stage needed for very low ultimate pressure and fast crossover. | BD 0100 A vs BD 0300 A / BD 0600 A |