COBRA DS 0600 E — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Busch COBRA DS 0600 E dry screw vacuum pump datasheet (single model, 50/60 Hz). Optional tantal coating for harsh applications is mentioned; dimensions, pumping speed curve and accessories referenced via dimensional drawing.
Section-by-Section Technical Breakdown
The COBRA DS 0600 E is a dry screw vacuum pump aimed at semiconductor-type processes such as chemical vapor deposition, rapid thermal processing, and atomic layer deposition. It features an advanced screw design, indirect water cooling, high hydrogen throughput, and a directly mounted canned motor in a compact fit-in-place design. Low maintenance and long service intervals are claimed for low cost of ownership.
- Advanced screw design with excellent running qualities
- Suited for CVD, rapid thermal processing, and atomic layer deposition
- Efficient indirect water cooling and high hydrogen throughput
- Minimal maintenance, long service intervals, high uptime
- Compact fit-in-place design with directly mounted canned motor
- Tantal coating available as an option for harsh applications
Key performance data are given for both 50 and 60 Hz operation, with pumping speed measured on air at 20°C and a tolerance of ±10%. The pump achieves 600 m³/h nominal pumping speed and 0.01 hPa ultimate pressure, driven by a 15 kW canned motor at 3600 min⁻¹. Cooling water, purge nitrogen, noise, weight, dimensions, and connection sizes are specified.
- Nominal pumping speed: 600 m³/h (50/60 Hz), tolerance ±10% (air at 20°C)
- Ultimate pressure: 0.01 hPa (mbar) (50/60 Hz)
- Nominal motor rating: 15 kW; power consumption at ultimate pressure: 9 kW
- Nominal motor speed: 3600 min⁻¹
- Sound pressure level (ISO 2151): < 70 dB(A), KpA = 3 dB
- Cooling water consumption: min. 6 l/min
- Nitrogen consumption: 0–200 l/min (purge range)
- Weight: approx. 745 kg; dimensions 1654 x 600 x 747 mm (L x W x H)
- Gas inlet / outlet: DN 100 / DN 63
Page 2 contains a dimensional drawing and a pumping speed curve (air at 20°C, ±10% tolerance), referenced graphically rather than numerically. Contact information is provided via the Busch website contact form.
- Dimensional drawing provided on page 2
- Pumping speed curve for air at 20°C with ±10% tolerance
- Further information via www.buschvacuum.com contact form
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Nominal pumping speed is 600 m³/h at both 50 and 60 Hz, with a stated tolerance of ±10% (measured on air at 20°C). p.2 ↗ | Size the vacuum system with up to 10% margin below nominal speed; performance is identical at both supply frequencies. | COBRA DS 0600 E |
| Ultimate pressure is 0.01 hPa (mbar) at 50/60 Hz. p.2 ↗ | Suitable as a backing or process pump for high-vacuum-relevant processes like ALD and CVD where low base pressure matters. | COBRA DS 0600 E |
| Nominal motor rating is 15 kW; power consumption at ultimate pressure is 9 kW (50/60 Hz). p.2 ↗ | Electrical supply and protection must be dimensioned for 15 kW, but steady-state load near ultimate pressure is only ~9 kW; energy cost estimates can use the 9 kW figure. | COBRA DS 0600 E |
| Nominal motor speed is 3600 min⁻¹ at both 50 and 60 Hz, with a directly mounted canned motor. p.2 ↗ | Identical speed at both line frequencies suggests inverter/frequency-converter-driven motor; no pulley or gearing changes needed between 50 Hz and 60 Hz installations. | COBRA DS 0600 E |
| Cooling is indirect water cooling with a minimum water consumption of 6 l/min. p.1 ↗ | A cooling water circuit supplying at least 6 l/min must be available at the installation site; oil-free/dry operation means no lubricant in the pumped gas path. | COBRA DS 0600 E |
| Nitrogen consumption (purge) is adjustable in the range 0–200 l/min. p.2 ↗ | Provision an N2 supply with flow regulation up to 200 l/min for process dilution/purging (e.g., corrosive or condensable media handling). | COBRA DS 0600 E |
| Sound pressure level is < 70 dB(A) per ISO 2151 with KpA = 3 dB. p.2 ↗ | Typically installable without dedicated acoustic enclosures in most industrial environments; verify against local workplace noise limits considering the ±3 dB uncertainty. | COBRA DS 0600 E |
| Gas connections are DN 100 inlet and DN 63 outlet. p.2 ↗ | Vacuum line piping and accessories (valves, traps, flexible connectors) must match DN 100 (inlet) and DN 63 (outlet) flange standards. | COBRA DS 0600 E |
| Weight is approximately 745 kg with overall dimensions of 1654 x 600 x 747 mm (L x W x H). p.2 ↗ | Foot structure, lifting equipment (e.g., crane or forklift rated >745 kg), and floor loading must accommodate the mass; the 600 mm width suits compact fit-in-place installations. | COBRA DS 0600 E |
| A tantal coating option is available for harsh applications. p.1 ↗ | For corrosive process gases (e.g., in CVD/ALD service), specify the tantal-coated variant at ordering time, as it is an option rather than a retrofit-friendly feature. | COBRA DS 0600 E (option) |
| The pump uses a dry screw operating principle with no in-process lubrication, enabling high hydrogen throughput. p.1 ↗ | Suitable for hydrogen-containing process gases without risk of oil contamination or hydrogen-induced lubricant degradation; no oil management in the gas path. | COBRA DS 0600 E |