Induztr
Engineering Digest Document Viewer Related Models

COBRA DS 0700 G — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Two-page Busch datasheet for the COBRA DS 0700 G, DS 1000 G and DS 2000 G dry screw vacuum pumps with integrated vacuum booster and canned motor; technical data given for 50 Hz and 60 Hz operation.

Section-by-Section Technical Breakdown

pp. 1
Product Overview

Describes the COBRA DS 0700–2000 G family as high-performance dry screw vacuum pumps with an advanced screw design and integrated vacuum booster. Applications named are chemical vapor deposition, rapid thermal processing and atomic layer deposition. Key selling points are efficiency, long service intervals and compact fit-in-place design.

  • Advanced screw design with integrated vacuum booster, suited to CVD, RTP and ALD processes
  • Indirect water cooling and high hydrogen throughput
  • Directly mounted canned motor; backing pump and vacuum booster combined on a compact base frame
pp. 2
Technical Data and Dimensions

Tabulated performance data for the three models at 50/60 Hz, including pumping speed, ultimate pressure, motor ratings, sound level, consumption and dimensions. Pumping speed curves are for air at 20°C with ±10% tolerance.

  • Nominal pumping speed: 500/610 m³/h (DS 0700 G), 775/960 m³/h (DS 1000 G), 1365/1640 m³/h (DS 2000 G) at 50/60 Hz
  • Ultimate pressure 0.003 hPa (mbar) for all models at 50/60 Hz
  • Motor ratings (backing pump / booster): 4.0/4.0 kW (DS 0700, 1000), 5.5/5.5 kW (DS 2000) at 50 Hz; +10% at 60 Hz
  • Motor speed 3000/3600 min⁻¹ for both backing pump and booster on all models
  • Sound pressure level < 62 dB(A) (DS 0700, DS 1000), < 68 dB(A) (DS 2000), ISO 2151, KpA = 3 dB
  • Water consumption 5.0 l/min and nitrogen consumption 0–75 l/min for all models
  • Weights: 445 / 576 / 668 kg; dimensions 865x385x917 / 1034x425x1017 / 1063x465x1069 mm
  • Gas inlet/outlet: DN 63/DN 40 (DS 0700), DN 100/DN 40 (DS 1000), DN 160/DN 40 (DS 2000)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ultimate pressure is 0.003 hPa (mbar) for all three models at both 50 and 60 Hz. p.2 ↗ Same base vacuum across the range; model choice is driven by pumping speed, not ultimate pressure. COBRA DS 0700/1000/2000 G
Nominal pumping speeds: 500/610 m³/h (DS 0700 G), 775/960 m³/h (DS 1000 G), 1365/1640 m³/h (DS 2000 G) at 50/60 Hz. p.2 ↗ 60 Hz operation gives ~20–22% more pumping speed, relevant when deploying on 60 Hz grids. whole series
Pumping speed curves are measured with air at 20°C, tolerance ±10%. p.2 ↗ Allow ±10% margin in system sizing calculations. whole series
Both backing pump and booster motors are rated 4.0 kW (DS 0700/1000) and 5.5 kW (DS 2000) at 50 Hz; 4.4/6.6 kW at 60 Hz. p.2 ↗ Total connected load is roughly 8–11 kW depending on model/supply frequency; size electrical supply accordingly. whole series
Power consumption at ultimate pressure/idle mode: 3.0/3.6 kW, 3.3/4.0 kW, 5.6/6.8 kW (50/60 Hz) for DS 0700/1000/2000 G. p.2 ↗ Base load at vacuum is significantly below nominal motor rating; useful for energy cost estimation. whole series
Water consumption is 5.0 l/min for all models (indirect cooling). p.2 ↗ Cooling water loop must supply 5 l/min continuously per pump. whole series
Nitrogen consumption is adjustable 0–75 l/min. p.2 ↗ Provision purge gas supply sized up to 75 l/min per pump if purge is required. whole series
Nominal motor speed is 3000/3600 min⁻¹ for both backing pump and booster. p.2 ↗ High-speed direct-drive operation; vibration and balance considerations at 2-pole speeds. whole series
Sound pressure level < 62 dB(A) for DS 0700/1000 G and < 68 dB(A) for DS 2000 G (ISO 2151, KpA = 3 dB). p.2 ↗ Noise rarely a limiting factor even for lab/cleanroom installation; DS 2000 is ~6 dB louder. whole series
Inlet/outlet flanges: DN 63/DN 40 (DS 0700), DN 100/DN 40 (DS 1000), DN 160/DN 40 (DS 2000). p.2 ↗ Outlet is uniformly DN 40 — matching backing-line hardware across the series is simplified. whole series, per-model inlet
Footprint/height: 865x385x917 mm and 445 kg (DS 0700), 1034x425x1017 mm and 576 kg (DS 1000), 1063x465x1069 mm and 668 kg (DS 2000). p.2 ↗ Foundation and lifting equipment must be rated ≥700 kg for the largest model; compact footprint eases retrofits. whole series
Canned motor is directly mounted, with backing pump and booster combined on a single base frame. p.1 ↗ No shaft seals/coupling alignment needed on site; installation is simplified but motor repairs are more specialized. whole series