UnoLine BA 501 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum BA 501 single-stage rotary vane vacuum pump datasheet (leaflet, 2 pages). No ordering matrix or variants given; covers accessories/options (isolation valve, venting valve, dust separator, vibration isolators, service kit, oil mist separator).
Section-by-Section Technical Breakdown
Highlights the pump's reliability, robustness and performance characteristics. Oil reservoirs for bearings and compression chamber are separated, so oil contamination does not affect bearing lifetime. An oil regeneration unit, easy condensate drainage, and very high vapor tolerance are claimed.
- Separated oil reservoirs for bearings and compression chamber — no influence on bearing lifetime
- Oil regeneration unit and easy condensate drainage
- Extremely high vapor tolerance of 14,000 g/h, designed for high gas-ballast flows
- Accessories/options: isolation valve, venting valve, dust separator, vibration isolators, service kit, oil mist separator
Nominal performance and mechanical data for the BA 501 at 50/60 Hz. Includes pumping speed, ultimate pressures with gas-ballast open/closed, motor data, oil capacity, weight, dimensions, and flange connections.
- Nominal pumping speed: 500 m³/h
- Ultimate pressure: 6·10⁻² hPa (gas-ballast closed); 1 hPa (gas-ballast open)
- Three-phase motor, 15/18 kW at 50/60 Hz, 1500/1800 min⁻¹
- Oil capacity 45 l; weight approx. 1100 kg
- Dimensions 1907 x 885 x 1070 mm (L x W x H)
- Gas inlet DN 100 ISO-F / outlet DN 100 ISO-K
- Pumping speed curve measured on air at 20 °C, tolerance ±10%
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Water vapor tolerance is 14,000 g/h, designed for high gas-ballast flows. p.1 ↗ | Suitable for wet processes without condensate-critical pre-separation, but expect higher ultimate pressure when gas ballast is used. | BA 501 |
| Ultimate pressure is 6·10⁻² hPa with gas-ballast valve closed and 1 hPa with it open. p.2 ↗ | Opening the gas ballast degrades base pressure by more than one order of magnitude; choose operating mode based on vapor load vs. base pressure requirement. | BA 501 |
| Nominal pumping speed is 500 m³/h (air at 20 °C, ±10% tolerance). p.2 ↗ | Size downstream processes to ~450–550 m³/h effective performance. | BA 501 |
| Three-phase motor rated 15 kW (50 Hz) / 18 kW (60 Hz) at 1500/1800 min⁻¹. p.2 ↗ | Electrical supply, cabling and starter/frequency sizing must cover 18 kW at 60 Hz operation. | BA 501 |
| Oil capacity is 45 l. p.2 ↗ | Plan oil inventory and drain/fill provisioning accordingly; single fill is substantial. | BA 501 |
| Pump weight is approx. 1100 kg with footprint 1907 x 885 x 1070 mm (L x W x H). p.2 ↗ | Requires heavy-duty foundations/lifting equipment and floor space planning; consider vibration isolators accessory. | BA 501 |
| Connections are DN 100 ISO-F inlet and DN 100 ISO-K outlet. p.2 ↗ | Vacuum line components and adapters must match DN 100 ISO flange standards; inlet and outlet use different clamp styles (F vs K). | BA 501 |
| Bearing lubrication and compression chamber use separated oil reservoirs. p.1 ↗ | Process-contaminated pump oil does not affect bearing lifetime; each reservoir needs separate oil maintenance attention. | BA 501 |
| An oil regeneration unit and easy condensate drainage are integrated features. p.1 ↗ | Condensate management can be handled during operation, supporting continuous wet-process running. | BA 501 |
| Available accessories: isolation valve, venting valve, dust separator, vibration isolators, service kit, oil mist separator. p.1 ↗ | Specify isolation/venting valves and oil mist separator for system integration and exhaust treatment; dust separator recommended for particle-laden processes. | BA 501 |