OmniStar — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum OmniStar GSD 350 and ThermoStar GSD 350 quadrupole mass spectrometers (gas analysis versions of the GSD 350 series). Variants: mass ranges 1-100 / 1-200 / 1-300 u, standard or corrosive gas version, choice of filament material, capillary operating temperature versions (200/350 °C), and various inlet systems. The two models differ mainly in gas connection/inlet: OmniStar uses stainless steel or quartz capillary with a software-controlled inlet valve; ThermoStar uses a quartz capillary continuously open.

Section-by-Section Technical Breakdown

pp. 1
Product Highlights

The document positions the OmniStar/ThermoStar GSD 350 as user-friendly, compact and lightweight portable quadrupole mass spectrometers for gas analysis. Key claims include automatic calibration and tuning, low detection limits, multi-gas analysis, and detection of small concentrations of reactive and condensable gases.

  • User-friendly: easy operation, automatic calibration and tuning
  • Compact and lightweight, portable
  • High performance: low detection limits, multi-gas analysis
  • Capable of detecting even small concentrations of reactive and condensable gases
pp. 1
Accessories, Spare Parts and Options

A list of available spare parts and configurable options for the GSD 350 series. Options affect mass range, gas compatibility, filament material, calibration and the inlet system.

  • Spare inlet systems, electronics, ion source, filament, analyzer
  • Spare vacuum gauge and vacuum pump
  • Mass ranges as an option
  • Standard or corrosive gas version
  • Choice of filament material
  • Mass calibration option
  • Various inlet systems
pp. 2-3
Technical Specifications and Dimensional Drawing

Side-by-side specifications for OmniStar and ThermoStar variants, including mass range, detection limit, rod system, electronics (PrismaPro), detectors, resolution, interfaces and physical/electrical data. Both models share nearly all performance parameters; the main difference is the gas inlet arrangement.

  • Mass range: 1-100 / 1-200 / 1-300 u (both models)
  • Gas connection: OmniStar stainless steel or quartz capillary; ThermoStar quartz capillary only
  • Gas inlet: OmniStar via software-controlled inlet valve or user interface; ThermoStar continuously open
  • Detection limit: < 100 ppb / < 1 ppm / < 10 ppm depending on mass range variant
  • Sample gas pressure up to 1200 hPa (mbar); two-stage, segregation-free pressure reduction
  • Rod system: stainless steel, 6 mm diameter, 125 mm length
  • Electronics: PrismaPro; detectors: C-SEM and Faraday
  • Contribution to neighboring mass: < 10 / < 20 / < 50 ppm; resolution (adjustable, at 10% peak height) 0.5-2.5 u
  • Dwell time 1 ms - 16 s/u; gas flow rate 1-2 sccm
  • Dimensions 615 x 358 x 274 mm; weight approx. 23-26 kg; supply voltage 100-240 V AC
  • Operating temperature of capillary up to 200/350 °C depending on version
pp. 3
Interfaces, Operation and Software

Connectivity, control and software environment for both models. Operation is via a 7" color touch screen or a web user interface, with PV MassSpec as the software platform.

  • Interface: Ethernet; analog input 5x ±10 V / 16 bit; analog output 4x 0...10 V / 16 bit; digital input 4x; digital output 6x sink, optically insulated, 24 V; relay 2x
  • Operation via 7" colored touch screen or Web User Interface
  • Software: PV MassSpec

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Detection limit is < 100 ppb for the 1-100 u mass range, < 1 ppm for 1-200 u, and < 10 ppm for 1-300 u p.2 ↗ Select the smallest mass range that covers the target gases to obtain the best detection limit; trace-gas applications below 1 ppm require the 1-100 u variant both OmniStar and ThermoStar GSD 350
Sample gas pressure can be up to 1200 hPa (mbar), handled via a two-stage, segregation-free pressure reduction p.2 ↗ The analyzer can sample near-atmospheric process gas directly without an external vacuum pumping stage between sample and inlet, provided the built-in pressure reduction is used whole series
Capillary operating temperature is up to 200 °C or 350 °C depending on version p.2 ↗ Choose the 350 °C version for hot process gases or condensable species; the capillary temperature must be set above the dew point of condensable components whole series, ordering variant dependent
Rod system is stainless steel, 6 mm diameter, 125 mm length p.2 ↗ Small-diameter rod system defines resolution/sensitivity trade-off; corrosive-gas applications require the corrosive version option since bare stainless steel is attack-prone whole series
Resolution is adjustable 0.5-2.5 u at 10% peak height; contribution to neighboring mass is < 10 / < 20 / < 50 ppm p.2 ↗ Resolution can be tuned per application; peak overlap (e.g., isobaric fragments) must be checked against the ≤10-50 ppm crosstalk figures for the respective mass range variant whole series
Dwell time is adjustable from 1 ms to 16 s per u; gas flow rate is 1-2 sccm p.2 ↗ Fast events can be monitored at 1 ms dwell times; the low sample flow (1-2 sccm) means minimal disturbance to the process gas system whole series
OmniStar gas inlet is via a software-controlled inlet valve or user interface; ThermoStar inlet is continuously open p.2 ↗ For applications requiring intermittent sampling or inlet control by the measurement routine, choose OmniStar; ThermoStar (quartz capillary only, continuously open) suits continuous high-temperature process monitoring model selection OmniStar vs ThermoStar
Supply voltage is 100-240 V AC p.2 ↗ No line-voltage variant selection needed; unit connects to standard single-phase supplies worldwide whole series
Dimensions are 615 x 358 x 274 mm and weight approx. 23-26 kg p.2 ↗ Bench/packaging design must accommodate a ~26 kg portable unit; mounting surfaces and handles must be rated accordingly whole series
Mass spectrometer electronics are the PrismaPro platform with C-SEM and Faraday detectors p.2 ↗ Detector choice (C-SEM for low-level signals, Faraday for high signals/large dynamic range) affects detection strategy; spare analyzer/ion source/filament are available as spare parts whole series
I/O: Ethernet; analog input 5x ±10 V / 16 bit; analog output 4x 0...10 V / 16 bit; digital input 4x; digital output 6x sink, optically insulated, 24 V; relay 2x p.3 ↗ PLC integration possible without additional I/O converters; digital outputs are sink-type, optically isolated at 24 V — design the receiving circuitry accordingly whole series
Operation via 7" color touch screen or Web User Interface; software is PV MassSpec p.3 ↗ Remote commissioning/monitoring can run through the Ethernet web UI; PV MassSpec license/system must be part of the plant software plan whole series
Mass ranges available: 1-100 u, 1-200 u, 1-300 u; options include standard vs corrosive gas version, filament material choice, mass calibration option and various inlet systems p.1 ↗ Ordering must specify mass range, gas version (corrosive for aggressive media), filament material, inlet system and capillary temperature version (200/350 °C) whole series, ordering configuration
Automatic calibration and tuning are built in; the instrument supports analysis of reactive and condensable gases p.1 ↗ No manual tuning expertise needed for routine operation, but corrosive-gas or condensable-species sampling should use the corresponding version/heated capillary option to avoid damage and condensation whole series