COMBI RD 1002 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum COMBI RD vacuum pump unit series datasheet covering three variants: COMBI RD 1002 (HiLobe 1302 booster + DuoVane 135 backing pump), COMBI RD 1604 (HiLobe 2104 + DuoVane 135), COMBI RD 2054 (HiLobe 2704 + DuoVane 300). Also lists accessories, spare parts and options.

Section-by-Section Technical Breakdown

pp. 1
Product Overview and Features

Describes the COMBI RD vacuum pump unit as reliable, high-performance and flexible. Reliability comes from process monitoring via integrated sensors and an intelligent user interface; performance from high pumping speed at low ultimate pressures, fast pump-down and high energy efficiency. Flexibility comes from combinations of oil-lubricated two-stage rotary vane backing pumps and vacuum boosters.

  • High uptime and increased safety thanks to process monitoring via integrated sensors
  • Intelligent user interface on the vacuum booster
  • High pumping speed at low ultimate pressures, fast pump-down times, high energy efficiency
  • Various design options and combinations of backing pumps and boosters available
pp. 1
Accessories, Spare Parts and Options

Lists available accessories and options for the COMBI RD series, including control and monitoring units, filters, separators, gas-ballast kit and mounting feet options.

  • Control unit for booster and backing pump
  • Oil mist separator; OFC (chemical oil filter); OFM (mechanical oil filter)
  • Gas-ballast valve kit
  • Operations monitoring unit
  • SAS (dust separator); KAS (condensate separator)
  • Feet options: height-adjustable machine foot, castor wheels, floor mounting
pp. 2
Technical Data

Performance and interface data table for the three COMBI RD models, including pumping speed, ultimate pressure (with/without gas ballast), power consumption, voltage, noise level, weight, and flange connections.

  • COMBI RD 1002: 975 m³/h pumping speed at 1 hPa; ultimate pressure 5·10⁻⁴ hPa (9·10⁻⁴ hPa with gas ballast); 6.5 kW max; 500 kg
  • COMBI RD 1604: 1644 m³/h at 1 hPa; ultimate pressure 9·10⁻⁴ hPa (2·10⁻³ hPa with gas ballast); 11 kW max; 650 kg
  • COMBI RD 2054: 2037 m³/h at 1 hPa; ultimate pressure 9·10⁻⁴ hPa (2·10⁻³ hPa with gas ballast); 11 kW max; 790 kg
  • All models: 400 V AC (±10%), 50 Hz; noise level ≤75 dB(A) per ISO 2151 at 1 hPa
  • Gas inlet/outlet: RD 1002 DN 100 ISO-F/PN 16 / DN 63 ISO-F; RD 1604 DN 100 ISO-F/PN 16 / DN 100 ISO-F; RD 2054 DN 160 ISO-F/PN 16 / DN 100 ISO-F

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
COMBI RD 1002 delivers 975 m³/h pumping speed at 1 hPa with ultimate pressure 5·10⁻⁴ hPa (mbar) p.2 ↗ Suitable for the smallest duty of the series; best ultimate pressure of the range, useful for processes needing low base pressure without gas ballast COMBI RD 1002
COMBI RD 1604 delivers 1644 m³/h at 1 hPa; COMBI RD 2054 delivers 2037 m³/h at 1 hPa p.2 ↗ Roughly doubles RD 1002 capacity; select based on required pump-down time and chamber volume COMBI RD 1604 / 2054
Ultimate pressure degrades with gas ballast: RD 1002 from 5·10⁻⁴ to 9·10⁻⁴ hPa; RD 1604/2054 from 9·10⁻⁴ to 2·10⁻³ hPa p.2 ↗ Use the gas-ballast valve kit only when condensate/vapor handling is required; expect a factor ~2 worse base pressure whole series
Max power consumption is 6.5 kW (RD 1002) and 11 kW (RD 1604 and RD 2054) p.2 ↗ Size electrical supply and breakers accordingly; note RD 1604 and RD 2054 share the same power rating despite different pumping speeds whole series
Input voltage is 400 V AC ±10% at 50 Hz for all models p.2 ↗ Requires a three-phase 400 V/50 Hz supply; ±10% tolerance defines acceptable grid variation whole series
Noise level ≤75 dB(A) (ISO 2151) at 1 hPa for all models p.2 ↗ Workplace noise planning can assume ≤75 dB(A) under the stated condition; typically still warrants hearing protection assessment whole series
Approximate weights: 500 kg (RD 1002), 650 kg (RD 1604), 790 kg (RD 2054) p.2 ↗ Plan lifting equipment, floor loading and mounting feet (height-adjustable feet, castors, or floor mounting) accordingly whole series
Gas inlet/outlet flanges: RD 1002 DN 100 ISO-F/PN 16 in, DN 63 ISO-F out; RD 1604 DN 100 ISO-F/PN 16 in, DN 100 ISO-F out; RD 2054 DN 160 ISO-F/PN 16 in, DN 100 ISO-F out p.2 ↗ Match inlet piping and pressure-rated (PN 16) connections to the specific model; RD 2054 needs DN 160 inlet hardware model-specific
Backing pumps used: DuoVane 135 (RD 1002 and RD 1604) and DuoVane 300 (RD 2054); boosters: HiLobe 1302/2104/2704 respectively p.2 ↗ Spare parts and service kits must match the specific booster/backing pump combination, not just the COMBI RD model number model-specific
Optional accessories include OFC chemical oil filter and OFM mechanical oil filter p.1 ↗ Choose OFC for chemically contaminated processes, OFM for particulate/purely mechanical duty whole series
SAS dust separator and KAS condensate separator are available as options p.1 ↗ Fit SAS for dusty processes and KAS when condensate is expected at the exhaust to protect the backing pump whole series
An operations monitoring unit and a control unit for booster and backing pump are offered as options p.1 ↗ For unmanned or safety-critical installations, integrate these to exploit the unit's sensor-based process monitoring whole series