Induztr
Engineering Digest Document Viewer Related Models

HiScroll 46 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiScroll 46 scroll vacuum pump datasheet. Variants/options listed: single-phase VSD, single-phase VSD with integrated pressure gauge, three-phase version, C-version (corrosive gas), plus accessories: tip seal replacement kit, tip seal and bearing replacement kit, gas-ballast valve kit, bellow kit, cover kit, electronics kit, exhaust silencer, inlet filter, automated vacuum safety valve, OmniControl control device, EtherCAT and Profinet converters.

Section-by-Section Technical Breakdown

pp. 1
Features, Accessories and Options

Highlights the HiScroll 46 as a high-performance, quiet, compact scroll pump with an IPM synchronous motor producing less heat than conventional drives. Lists available accessories, spare parts, and version options including corrosive-gas and network-converter variants.

  • Fastest pump-down time in its class; highly energy-efficient interior permanent magnet (IPM) synchronous motor generating less heat than conventional drives
  • Sound pressure level less than 47 dB(A) in single-phase version
  • Smallest and lightest pump in its performance class, suited for laboratory applications
  • Accessories/spare parts: tip seal replacement kit, tip seal and bearing replacement kit, gas-ballast valve kit, bellow kit, cover kit, electronics kit, exhaust silencer, inlet filter
  • Options: automated vacuum safety valve, OmniControl control device, EtherCAT converter, Profinet converter
  • Versions: single-phase VSD, single-phase VSD with integrated pressure gauge, three-phase, C-version for corrosive gas
pp. 2
Technical Data and Dimensions

Key performance figures for the HiScroll 46 including pumping speed, ultimate pressures at various gas-ballast settings, power consumption, dimensions, and connection sizes. Pumping speed curves are given for air at 20 °C with ±10% tolerance at 50 Hz and 60 Hz.

  • Pumping speed: 43 m³/h (50 Hz and 60 Hz curves shown, tolerance ±10%)
  • Ultimate pressure (gas-ballast closed): 0.007 hPa (mbar)
  • Ultimate pressure (gas-ballast open stage 1): ≤0.03 hPa (mbar)
  • Ultimate pressure (gas-ballast open stage 2): ≤0.2 hPa (mbar)
  • Power consumption at ultimate pressure: 295 W
  • Motor speed 720–1800 min⁻¹; nominal 1800 min⁻¹
  • Sound pressure level ≤47 dB(A) (ISO 3744, accuracy grade 2)
  • Weight approx. 32 kg; dimensions 463 x 299 x 334 mm (L x W x H)
  • Gas inlet DN 40 ISO-KF; outlet DN 25 ISO-KF

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Pumping speed is 43 m³/h for air at 20 °C, with a ±10% tolerance on the speed curves p.2 ↗ Size the backing/fore-vacuum application with a 10% margin; curves exist for both 50 Hz and 60 Hz supply HiScroll 46
Ultimate pressure with gas-ballast valve closed is 0.007 hPa (mbar) p.2 ↗ Defines best achievable base vacuum; keep gas-ballast closed for finest ultimate pressure HiScroll 46
Gas-ballast open at stage 1 degrades ultimate pressure to ≤0.03 hPa; stage 2 to ≤0.2 hPa p.2 ↗ Operating with gas ballast for condensate handling costs roughly 4x–30x in ultimate pressure; select stage accordingly HiScroll 46 with gas-ballast valve kit
Power consumption at ultimate pressure is 295 W p.2 ↗ Low standby power draw; useful for sizing lab power budgets and energy cost estimates HiScroll 46
Motor speed range is 720–1800 min⁻¹ with nominal speed 1800 min⁻¹ p.2 ↗ Speed can be modulated down (VSD variants) for process control or reduced throughput HiScroll 46
Sound pressure level ≤47 dB(A) per ISO 3744 accuracy grade 2 (single-phase version <47 dB(A)) p.1 ↗ Suitable for noise-sensitive lab environments without additional acoustic enclosure HiScroll 46
Weight is approx. 32 kg; dimensions 463 x 299 x 334 mm p.2 ↗ Compact footprint for lab benches; plan handling/support for ~32 kg HiScroll 46
Gas inlet is DN 40 ISO-KF, outlet DN 25 ISO-KF p.2 ↗ Specify matching KF clamps, centering rings and a DN 25 foreline; inlet is larger than outlet HiScroll 46
IPM synchronous motor generates less heat than conventional drives p.1 ↗ Reduced thermal load on the pumped process and enclosure; beneficial for heat-sensitive applications HiScroll 46
A C-version is available for corrosive gas applications p.1 ↗ For corrosive processes, order the C-version rather than the standard pump to avoid premature wear HiScroll 46 C-Version
Fieldbus integration is available via EtherCAT or Profinet converters, and the OmniControl control device can be added p.1 ↗ Plan remote monitoring/control wiring if process automation is required HiScroll 46 with accessories
Maintenance kits exist for tip seal alone and tip seal plus bearing replacement p.1 ↗ Stock appropriate kits based on duty; tip seals are the primary wear item on scroll pumps HiScroll 46
Automated vacuum safety valve, inlet filter, and exhaust silencer are available as accessories p.1 ↗ Use the safety valve to protect the chamber on power failure; filter/silencer for particulate and noise control HiScroll 46
Three supply variants exist: single-phase VSD, single-phase VSD with integrated pressure gauge, and three-phase p.1 ↗ Match variant ordering to available site power; integrated gauge variant saves a separate measurement port HiScroll 46