Safety Data Sheet (DNA-500 Marker solution)
Technical Reference Summary
Covered Models & Document Scope
This document is a Safety Data Sheet (SDS) for DNA-500 Marker solution (product code 292-27888-01I), a buffer solution used with Shimadzu MultiNA and MultiNA II microchip electrophoresis systems. It covers the marker solution itself and references the DNA-500 KIT ASSY (P/N 292-27910-91, 292-27910-10, 292-27910-30), which includes DNA-500 Separation Buffer and DNA-500 Marker solution. The document does not cover instrument models, options, or ordering codes beyond these kit part numbers.
Section-by-Section Technical Breakdown
The product is a mixture containing tris(hydroxymethyl)aminomethane (<0.3%), boric acid (<0.2%), other non-hazardous components (<0.1%), and water (balance to 100%). Exact concentrations are withheld as confidential business information.
- tris(hydroxymethyl)aminomethane (CAS 77-86-1): < 0.3 %
- boric acid (CAS 10043-35-3): < 0.2 %
- Other non-hazardous components: < 0.1 %
- Water (CAS 7732-18-5): Balance to 100 %
No occupational exposure limits are established for the mixture, but ACGIH TWA/STEL values exist for boric acid. Engineering controls include eyewash equipment; personal protection requires impervious gloves, tightly sealed goggles, and a laboratory coat.
- ACGIH (Boric Acid): TWA 2 mg/m3 (I), STEL 6 mg/m3 (I)
- Eyewash equipment required
- Respiratory protection: Not required
- Hand protection: Wear impervious glove
- Eye protection: Wear tightly sealed goggles
- Skin and body protection: Wear laboratory coat
The product is a colorless, transparent, odorless liquid with a pH of 8.3 at 20°C. It is readily soluble, not flammable, and does not spontaneously combust.
- Physical state, color: Colorless, transparent liquid
- Odor: Odorless
- pH: 8.3 at 20°C
- Solubility: Readily soluble
- Flammability: Not applicable
- Auto-ignition temperature: The product does not combust spontaneously
The product is chemically stable under standard ambient conditions. Hazardous reactions have not been reported. Avoid physical stress such as direct sunlight, excess heat, or electrostatic discharge.
- Stable under standard ambient conditions
- Hazardous reaction has not been reported
- Avoid physical stress e.g., direct sunlight, excess heat, or electrostatic discharge
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| pH is 8.3 at 20°C. p.2 ↗ | The marker solution is mildly alkaline; verify compatibility with microchip electrophoresis buffers and avoid acidic contamination. | DNA-500 Marker solution |
| Boric acid concentration is < 0.2 %. p.1 ↗ | Boric acid is present at low concentration; ACGIH exposure limits for boric acid (TWA 2 mg/m3, STEL 6 mg/m3) apply for occupational exposure assessment. | DNA-500 Marker solution |
| tris(hydroxymethyl)aminomethane concentration is < 0.3 %. p.1 ↗ | The buffer component is present at low concentration; no specific exposure limits are established for the mixture. | DNA-500 Marker solution |
| Store in a dark, cool, well-ventilated place and keep tightly closed. p.1 ↗ | Protect from light and heat to maintain stability; ensure containers are sealed to prevent evaporation or contamination. | DNA-500 Marker solution |
| Avoid direct sunlight, excess heat, or electrostatic discharge. p.2 ↗ | Handle and store away from sunlight and heat sources; use appropriate grounding if electrostatic discharge is a concern. | DNA-500 Marker solution |
| Wear impervious gloves, tightly sealed goggles, and a laboratory coat when handling. p.2 ↗ | Personal protective equipment is required to prevent skin and eye contact; eyewash equipment should be available. | DNA-500 Marker solution |
| No transport classification assigned for US DOT, IMDG, ADR/RID, or ICAO/IATA. p.3 ↗ | The product is not regulated as dangerous goods for transport; standard shipping precautions apply. | DNA-500 Marker solution |
| DNA-500 KIT ASSY includes DNA-500 Separation Buffer and DNA-500 Marker solution (P/N 292-27910-91, 292-27910-10, 292-27910-30). p.1 ↗ | When ordering the kit, both separation buffer and marker solution are supplied; ensure compatibility with MultiNA/MultiNA II systems. | DNA-500 KIT ASSY |
| The product is a colorless, transparent, odorless liquid. p.2 ↗ | Visual inspection for color or clarity can help detect contamination or degradation. | DNA-500 Marker solution |
| The product is readily soluble. p.2 ↗ | It mixes readily with aqueous systems; ensure proper mixing when preparing reagents. | DNA-500 Marker solution |
| The product does not combust spontaneously. p.1 ↗ | No auto-ignition hazard under normal conditions; however, combustion may produce carbon monoxide, nitrogen oxides, and boric oxides. | DNA-500 Marker solution |
| In case of eye contact, flush eyes with plenty of water for at least 15 minutes and obtain medical attention. p.1 ↗ | Immediate and prolonged rinsing is required for eye exposure; eyewash equipment should be accessible. | DNA-500 Marker solution |
| Absorb spills with paper towel or sand and prevent leakage. p.1 ↗ | Use absorbent materials for cleanup; avoid environmental release. | DNA-500 Marker solution |
| No occupational exposure limit values are established for the mixture. p.2 ↗ | Use general ventilation and protective equipment as per boric acid limits. | DNA-500 Marker solution |
| The product is stable under standard ambient conditions. p.2 ↗ | No special stability precautions beyond avoiding light, heat, and electrostatic discharge are required. | DNA-500 Marker solution |