Engineering Digest Document Viewer Related Models

321-78454

Technical Reference Summary

Covered Models & Document Scope

Covers the TW, TX, and TXB series balances. TXB series includes a backlight and an additional display symbol. TW series has internal weight calibration functions. Some functions (e.g., WindowsDirect) are not applicable to verified balances with EC Type Approval. Unit availability (mg, kg) depends on model minimum indication and series (kg not selectable on TWC***L and TXC***L).

Section-by-Section Technical Breakdown

pp. 1
Display Panel Indicators

The display panel includes symbols for battery, zero tracking, weight, easy setting, pouring, formulation, menu lock, menu operation keys, auto print, Win, communication, comparator, stability, minus, ready, number, hold, net/gross weight, item number, inverse triangle, piece counting, and percentage weighing. Each symbol indicates a specific operating state or function.

  • Battery symbol lit when weight reading is stable or when an option set in menu is displayed.
  • Zero tracking symbol lit when zero tracking function is ON.
  • Weight symbol lit during calibration.
  • Easy setting indicator shows current response and stability level.
  • Pouring symbol lit when pouring mode is set.
  • Formulation symbol lit during mixing measurement (formulation) operations.
  • Menu lock symbol lit while menu is locked.
  • Menu operation key symbol indicates which menu keys can be used.
  • Auto print symbol lit when Auto Print function is set.
  • Win symbol lit when WindowsDirect communication function is set.
  • Communication symbol indicates data exchange with external device.
  • Comparator symbol indicates comparison judgment when checkweighing is set.
  • Stability mark lit when weight reading is stable or when an option set in menu is displayed.
  • Minus symbol lit when weight reading is negative.
  • Ready symbol lit during standby mode (TX series only) or ready to weigh status.
  • Number symbol lit when numerical values can be entered.
  • Hold symbol lit when a non-real-time value (e.g., unit weight in piece counting) is displayed.
  • Net weight symbol indicates net weight of current component in formulation.
  • Gross weight symbol indicates total weight of all components in formulation.
  • Item number indication shows item number in piece counting mode.
  • Inverse triangle symbol allows numerical entry without decimal point when changing decimal point position in conversion factor.
  • Piece counting symbol lit during piece counting mode.
  • Specific percentage weighing symbol lit when specific percentage reference is set.
  • Percentage weighing symbol lit during percentage weighing.
pp. 1
Operation Keys

The balance has operation keys ([BREAK], [CAL], [O/T], [PRINT]) and menu operation keys ([MENU/ENTER], [UNIT], [FUNC], [Res], [Stb]). Each key has functions for short press (once and release) and long press (about 3 seconds).

  • [BREAK] switches between operation and standby modes (short press).
  • [CAL] performs calibration (short press) or enters calibration menu (long press).
  • [O/T] tares the balance (short press) or opens zero/tare menu (long press).
  • [PRINT] outputs weight reading to peripheral (short press) or opens data output menu (long press).
  • [MENU/ENTER] displays main menu (short press) or shows last menu (long press).
  • [UNIT] selects unit, displays unit weight, or displays reference weight (short press); opens unit setting menu, selects item number, or selects percentage reference (long press).
  • [FUNC] switches between weighing mode and application function mode (short press) or selects minimum number of displayed digits (long press).
  • [Res] increases response of display.
  • [Stb] increases stability of display.
pp. 2
Menu Map

The menu map provides access to main menu, data output menu, unit setting menu, calibration menu, and zero/tare menu. It includes settings for weighing modes, application functions, communication parameters, calibration, and zero/tare functions.

  • Main menu includes STAND, POURING, WIN|, WIN|.U, WIN-, WIN-.U, Z.TRC, APL.FUNC, TOOLS, FORMULA, TG.VAL, LM.VAL, OVR.RNG, PARAM.W, STB.MK, BAND, SYSTEM, POINT, PERIOD, COMMA, FAST, SAMPLE, OPTION.
  • Data output menu includes APL.PRN, AUTO.PRN, SEQ.PRN, COMM.SET, MODE.1 to MODE.5, BPS, PARITY, STOP, HAND.SHK, D.FORM, DELIM, COMMA, etc.
  • Unit setting menu allows selection of g, mg, kg, ct, and user-specified units (UNIT-U).
  • Calibration menu includes CAL.EXE, E.CAL, E.TEST, I.CAL, I.TEST, P.CAL, GLP.OUT, CAL.REC.
  • Zero/tare menu includes Z.TRC, A.TARE, TARE.F, A.ZERO.
  • Menu navigation: press arrow keys to search, press to confirm, press to return to previous menu option; pressing for about 3 seconds returns to weighing mode.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Press and hold [CAL] for about 3 seconds to enter the calibration menu. p.1 ↗ Allows access to calibration functions such as span calibration and calibration check. TW/TX/TXB series
Press and hold [O/T] for about 3 seconds to open the zero/tare menu. p.1 ↗ Enables configuration of zero tracking, auto tare, tare timing, and auto zero functions. TW/TX/TXB series
Press and hold [PRINT] for about 3 seconds to open the data output menu. p.1 ↗ Provides access to communication settings, print formats, and output timing. TW/TX/TXB series
Press and hold [UNIT] for about 3 seconds to open the unit setting menu. p.1 ↗ Allows selection of weighing units and user-defined units. TW/TX/TXB series
Press and hold [MENU/ENTER] for about 3 seconds to show the menu displayed last. p.1 ↗ Quick access to the most recently used menu. TW/TX/TXB series
The [Res] key increases the response of the display. p.1 ↗ Use to make the display react faster to weight changes. TW/TX/TXB series
The [Stb] key increases the stability of the display. p.1 ↗ Use to reduce display fluctuations for more stable readings. TW/TX/TXB series
The ready symbol is lit during standby mode (TX series only). p.1 ↗ Indicates standby status for TX series balances. TX series
The Win symbol is lit when the WindowsDirect communication function has been set. p.1 ↗ Indicates that the balance is configured for WindowsDirect data transfer. TW/TX/TXB series (not applicable to verified balances with EC Type Approval)
The battery symbol is lit when the weight reading is stable or when an option set in menu is displayed. p.1 ↗ Provides visual confirmation of stability or menu option selection. TW/TX/TXB series
The zero tracking symbol is lit when the zero tracking function is set ON. p.1 ↗ Indicates that automatic zero tracking is active. TW/TX/TXB series
The weight symbol is lit during calibration. p.1 ↗ Confirms that the balance is in calibration mode. TW/TX/TXB series
The easy setting indicator shows the current response and stability level. p.1 ↗ Allows quick assessment of current filter settings. TW/TX/TXB series
The pouring symbol is lit when the pouring mode is set. p.1 ↗ Indicates that the balance is configured for pouring applications. TW/TX/TXB series
The formulation symbol is lit during mixing measurement (formulation) operations. p.1 ↗ Shows that the balance is in formulation mode. TW/TX/TXB series
The menu lock symbol is lit while the menu is locked. p.1 ↗ Indicates that menu access is restricted. TW/TX/TXB series
The comparator symbol indicates the comparison judgment when the comparator function (Checkweighing) has been set. p.1 ↗ Provides visual feedback for checkweighing results. TW/TX/TXB series
The stability mark is lit when the weight reading is stable or when an option set in menu is displayed. p.1 ↗ Confirms stable weighing or menu selection. TW/TX/TXB series
The minus symbol is lit when the weight reading is negative. p.1 ↗ Indicates negative weight values. TW/TX/TXB series