±2% of reading, or ±0.2 mL/min, whichever is greater.
Accuracy*: 501 to 750 mL/min
±3% of reading
Tubing Temperature Range
–62 to 110 °C
Operating Temperature Range
0 to 45 °C
Storage Temperature Range†
–15 to 50 °C
Power
(3) AA batteries (alkaline), or USB power
Display
128 × 64 pixels monochrome with 16 gray scales
* When verified at ambient temperature of 20 to 24 °C at sea level. Optimum performance is in the range of 15 to 35 °C. Accuracy may decrease outside of these ranges. † Damage to the instrument may occur if it is exposed to temperatures greater than 50 °C, leading to inaccurate results.
Table
Раздел
Страница
Warning indication
28
Error indication
28
Low battery indication
29
Power Indications
30
Installing and Replacing the Cartridge
31
Installing the cartridge
31
Swapping or replacing the cartridge with ADM flow meter cartridge
31
Replacing the Batteries
33
Upgrading the Firmware/Retrieving Certificate of Calibration
35
Using the Flow Meter Stand
36
A Note About Backpressure
37
Technical Support
37
Other Features
37
Safety and Regulatory Certification
38
Class A EMC certification
38
Disposal
38
Flow (mL/min) / Display Resolution (mL/min)
Flow (mL/min)
Display Resolution (mL/min)
0.5 to 9.99
0.01
10.0 to 99.9
0.1
100 to 750
1.0
Table 2 Error and warning code descriptions
Error/ Warning Code
Type
Description
Troubleshooting
01 No Cal Info
Error
No calibration information
Contact Agilent Technical Support
02 No Verif
Error
Flow meter is not verified
Contact Agilent Technical Support
03 PresTemp Err
Error
Pressure/ temperature sensor failure
Contact Agilent Technical Support
04 No Cart
Error
No cartridge detected
Install a valid cartridge.
05 No MF Info
Warning
No mainframe information
Contact Agilent Technical Support
06 Auto Recover
Warning
Auto-recovery mode
Reboot the flow meter
Table 2 Error and warning code descriptions (continued)
Error/ Warning Code
Type
Description
Troubleshooting
07 Overflow
Warning
Measurement exceeds instrument range
Measure gas flow within the acceptable flow range
08 Cart Exp
Warning
Cartridge expired
Install a new cartridge
09 Low RTC Bat
Warning
RTC (real time clock) backup battery low
Contact Agilent Technical Support
10 Op Temp
Error
Out of operating temperature range condition (0 to 45 °C)
Operate the flow meter within the acceptable temperature range
11 Op Pres
Error
Out of operating atmospheric pressure range
Operate the flow meter within the acceptable atmospheric pressure range
12 Ver Mismatch
Error
Firmware version mismatch with cartridge version
Upgrade firmware to latest version
13 Invalid Cart
Error
Unable to identify cartridge types
Contact Agilent Technical Support
Engineering Facts
13 facts · every claim linked to a page
Safety
Flows above 750 mL/min can destroy the cartridge and void the warranty, so the measured flow must be kept within the instrument range.
Prevents cartridge damage and warranty loss during flow measurement.
Source
“Flows exceeding 750 mL/min may damage the cartridge and void the warranty.”
Safety
Only a 5 V DC, 0.5 A USB source and the supplied USB cable may be used to run the device.
Ensures correct and safe USB powering of the meter.
Source
“Use only a 5 V DC, 0.5 A USB power source and the supplied USB cable to run this device.”
Safety
The meter must not be used as safety equipment.
Defines the instrument as a measurement tool, not a protective device.
Source
“Do not use the ADM flow meter as safety equipment.”
Selection
The flow range is 0.5 to 750 mL/min with auto-ranging.
Confirms the meter covers the intended gas flow range.
Source
“0.5 to 750 mL/min,
auto-ranging”
Performance
Accuracy is ±2% of reading or ±0.2 mL/min (whichever is greater) from 0.5 to 500 mL/min, and ±3% of reading from 501 to 750 mL/min.
Sets the measurement uncertainty to expect at low and high flows.
Source
“±2% of reading, or
±0.2 mL/min, whichever
is greater.”
Operation
The meter must always be switched on before it is connected to a flow source.
Avoids measurement errors and potential cartridge stress during connection.
Source
“Always turn the flow meter on before connecting it to a flow source.”
Operation
Readings stabilize in 1 to 2 seconds, but flows below 1 mL/min may need up to 5 seconds.
Sets the waiting time before recording a valid low-flow measurement.
Source
“Low flows (less than 1 mL/min) may take up to 5 seconds for the reading to stabilize.”
Maintenance
The cartridge calibration is valid for one year from first use, and the meter still functions after expiry with a warning.
Plans cartridge replacement and calibration cycles without downtime.
Source
“The cartridge calibration is valid for a period of one year from its first use.”
Maintenance
The cartridge is replaced by loosening two captive thumbscrews and lifting it out of the mainframe.
Describes the field-replaceable cartridge procedure for maintenance.
Source
“Loosen both captive thumbscrews completley and lift the
cartridge out of the CrossLab CS Mainframe body.”
Operation
USB power does not recharge the installed batteries.
Prevents expecting battery recharge when running on USB power.
Source
“Using the USB port to supply power does not recharge the
installed batteries.”
Operation
In USB power mode the Auto off function is always off and cannot be changed.
Clarifies power behavior when the meter is USB-powered.
Source
“In USB power mode, the Auto off function is always off and the
option to change the Auto off setting is disabled.”
Operation
When connected to PC software, the meter buttons are disabled.
Explains why front-panel control is unavailable during data acquisition.
Source
“When the flow meter is connected to PC software, the buttons
on the flow meter are disabled.”
Performance
Soap bubble meters typically read slightly higher, by nearly 4% at room temperature due to water vapor.
Explains expected discrepancy versus bubble-type flow meters.
Source
“At room temperature, water vapor can raise readings by nearly 4%.”