Authenticity Evaluation of Insect Protein-Containing Food Products
Technical Reference Summary
Covered Models & Document Scope
Nota de aplicación que cubre la evaluación de autenticidad de productos alimenticios que contienen proteína de insecto utilizando el Agilent 1290 Infinity III Bio LC y el Agilent 6545XT AdvanceBio LC/Q-TOF; muestras N-BAR (control negativo) y C-BAR01 a C-BAR05 barritas proteicas.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| LC pump module | Agilent 1290 Infinity III Bio High-Speed p.3 ↗ | |
| Autosampler module | Agilent 1290 Infinity III Bio Multisampler p.3 ↗ | |
| Column temperature | 60 °C p.3 ↗ | |
| Needle wash | Acetonitrile using flush port, 3 sec p.3 ↗ | |
| Sheath gas temperature | 350 °C p.3 ↗ | |
| Sheath gas flow | 11 L/min p.3 ↗ | |
| Nebulizer pressure | 35 psig p.3 ↗ | |
| Mass range | m/z 300–3,200 p.3 ↗ | |
| Data acquisition rate | 8 spectra/s p.3 ↗ | |
| Isolation width | Medium (m/z 4) p.3 ↗ | |
| Enzyme-to-substrate ratio | 1:50 w/w p.3 ↗ | |
| Average MS/MS spectra | 78,683 p.4 ↗ | n = 3 |
| Average spectra submitted to database matches | 8,753 p.4 ↗ | n = 3 |
| Average unique peptides | 1,084 p.4 ↗ | n = 3 |
| Average % ID | 11.1 % p.4 ↗ | n = 3 |