Agilent CrossLab CS Electronic Leak Detector and ADM

Contenido

  1. Overview pp. 1-3
    Introduces the CrossLab CS leak detector and ADM for GC troubleshooting
  2. Overview p. 4
    Highlights simple operation and low ownership effort
  3. Procedure p. 5
    Describes calibration via simple cartridge replacement
  4. Overview p. 6
    Explains Agilent inert GC flow path technology
  5. Spec p. 7
    Lists technical specifications and ordering information
  6. p. 8
    Provides contact and further information
  7. p. 7 table, 5 rows

Ordering information

DescriptionPart number
Agilent ADM Flow MeterG6691A
ADM Flow meter replacement cartridgeG6692A
CrossLab CS Electronic Leak DetectorG6693A
Electronic leak detector cartridge onlyG6694A
CrossLab CS Bundle: ADM Flow Meter and Electronic Leak Detector—includes 1 handheld unit, 2 cartridges, and a free carrying caseG6699A

Engineering Facts

13 facts · every claim linked to a page
Selection

The system combines leak detection and flow measurement in one handheld unit, so a single purchase covers both GC flow-path diagnostics tasks.

Lets you specify one instrument instead of two separate tools, reducing cost and bench space.

Source
“A cartridge-based design combines leak detection and flow measurement into one ultimate GC diagnostics tool.”
Selection

The TCD sensor detects helium, hydrogen, and large nitrogen leaks, so it covers the common carrier and detector gases used in GC.

Confirms the detector is suitable for the gases in your lab before purchase.

Source
“The TCD sensor measures helium, hydrogen, and large nitrogen leaks so you can detect any changes in gas composition.”
Installation

Cartridge swap requires powering down first, then loosening two captive thumbscrews and hand-tightening the new cartridge.

Defines the physical installation procedure and tooling (none needed) for cartridge changes.

Source
“Loosen both captive thumbscrews and lift the old cartridge out of its holder.”
Maintenance

Firmware can be upgraded in minutes via computer and USB connection, so the unit can gain new functions without replacement.

Plan for a USB-capable PC and periodic firmware updates to keep the instrument current.

Source
“you can complete your upgrade in minutes by using your computer and USB connection”
Cumplimiento

An existing Agilent ADM Flow Meter becomes compatible with the leak detector cartridge after a simple firmware update.

Avoids buying a new mainframe if you already own an ADM Flow Meter.

Source
“the leak detector cartridge is fully compatible after a simple firmware update”
Maintenance

NIST-traceable calibration is maintained by swapping in a factory-precalibrated cartridge yourself instead of shipping the meter out.

Eliminates shipping downtime and recalibration turnaround when planning maintenance.

Source
“Simply order a factory-precalibrated cartridge and swap it yourself within minutes.”
Performance

The leak detector responds in about 2 seconds with under 1.5 seconds zeroing, enabling quick leak checks.

Fast response matters for efficient troubleshooting across many fittings.

Source
“2 sec. response time and < 1.5 sec. zeroing time.”
Performance

Helium leak sensitivity is 0.003 mL/min in atmosphere, supporting detection of very small leaks.

Sets the detection threshold you can expect when validating leak-tight connections.

Source
“0.003 mL/min. sensitivity (helium) plus easy-read OLED display and 49.9 dB audible beep.”
Operation

The flow meter autoranges from 0.5 to 750 mL/min, covering typical GC carrier and detector flows.

Verify the flow range matches your method flows before selecting the cartridge.

Source
“0.5 to 750 mL/min, autoranging”
Performance

Flow accuracy is ±2% of reading or ±0.2 mL/min, whichever is greater, defining measurement uncertainty.

Determines whether the meter meets your flow verification tolerance requirements.

Source
“± 2% of reading, or ± 0.2 mL/min, whichever is greater”
Installation

The flow meter cartridge tubing is rated from –62 to 110 °C, so it can be used on heated transfer lines within that range.

Check tubing temperature compatibility with the measurement point before installing.

Source
“–62 to 110 °C”
Operation

The mainframe runs on three AA alkaline batteries or USB power, allowing portable use or bench-powered operation.

Plan power source and battery logistics for field or bench use.

Source
“Three AA batteries (alkaline) or USB power”
Selection

The bundle includes one handheld unit, two cartridges, and a free carrying case, covering both functions in one order.

Confirms what is included so you order the correct part number for both functions.

Source
“includes 1 handheld unit, 2 cartridges, and a free carrying case”