Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1300 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 300: soplador de canal lateral con convertidor de frecuencia integrado (IP55) para montaje en pared, funcionamiento a 50 Hz y 60 Hz, funcionamiento con VFD en conexión delta a 87 Hz / 345 V, además de opciones de accesorios VFD (A–K) y accesorios (terminal portátil MMI, cable adaptador USB, transmisores de presión diferencial).

Technical Data

Parameter Value Condición
Rated mains voltage 345 V p.2 ↗ 2BH1300-1A221, 87 Hz, delta
Rated motor current 2,70 A p.2 ↗ 2BH1300-1A221, 87 Hz
Motor power 1,0 kW p.2 ↗ 2BH1300-1A221, 87 Hz
Max. differential pressure (vacuum) -160 mbar p.2 ↗ 2BH1300-1A221, 87 Hz
Max. differential pressure (pressure) 150 mbar p.2 ↗ 2BH1300-1A221, 87 Hz
Sound pressure level 62 dB(A) p.2 ↗ 2BH1300-1A221, 87 Hz
Weight 15 kg p.2 ↗ 2BH1300-1A221, 87 Hz
Max. differential pressure (vacuum) -80 mbar p.2 ↗ 2BH1300-1A221, 50 Hz
Max. differential pressure (pressure) 90 mbar p.2 ↗ 2BH1300-1A221, 50 Hz
Max. differential pressure (vacuum) -120 mbar p.2 ↗ 2BH1300-1A221, 50 Hz, VFD
Max. differential pressure (pressure) 130 mbar p.2 ↗ 2BH1300-1A221, 50 Hz, VFD
Sound pressure level 53 dB(A) p.2 ↗ 2BH1300-1A221, 50 Hz, VFD
Weight 10 kg p.2 ↗ 2BH1300-1A221, 50 Hz, VFD
Max. differential pressure (vacuum) -120 mbar p.2 ↗ 2BH1300-1A221, 60 Hz
Max. differential pressure (pressure) 110 mbar p.2 ↗ 2BH1300-1A221, 60 Hz
Sound pressure level 56 dB(A) p.2 ↗ 2BH1300-1A221, 60 Hz
Rated mains voltage 400 V p.2 ↗ 2BH1300-1A221, 87 Hz, delta
Rated motor current 1,65 A p.2 ↗ 2BH1300-1A221, 87 Hz, delta
Motor power 0,64 kW p.2 ↗ 2BH1300-1A221, 87 Hz, delta
Max. differential pressure (vacuum) -80 mbar p.2 ↗ 2BH1300-1A221, 87 Hz, delta
Max. differential pressure (pressure) 70 mbar p.2 ↗ 2BH1300-1A221, 87 Hz, delta

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Protection class of integrated frequency converter motor: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH13 Side channel blower series/type designation (2BH1 300)
6-7 p.2 ↗ 00 Size/variant field of the 2BH1 300 type
8-9 p.2 ↗ 1A Motor/voltage variant field
10-12 p.2 ↗ 221 Ordering variant suffix (2BH1300-1A221)
VFD type field 1 p.2 ↗ A Frequency converter size A (2FC4152-1□□00)
VFD type field 1 p.2 ↗ B Frequency converter size B (2FC4222-1□□00)
VFD type field 1 p.2 ↗ C Frequency converter size C (2FC4302-1□□00)
VFD type field 1 p.2 ↗ D Frequency converter size D (2FC4402-1□□00)
VFD type field 1 p.2 ↗ E Frequency converter size E (2FC4552-1□□00)
VFD type field 1 p.2 ↗ F Frequency converter size F (2FC4752-1□□00)
VFD type field 1 p.2 ↗ G Frequency converter size G (2FC4113-1□□00)
VFD type field 1 p.2 ↗ H Frequency converter size H (2FC4153-1□□00)

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1300-1A221 p.2 ↗ 2BH1300-1A221 87 Hz, 345 V, delta Blower with integrated frequency converter
2BH1300-1AP16 p.2 ↗ 2BH1300-1AP16 50 Hz Blower variant