Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1640 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 640: soplador de canal lateral 2BH1640 con convertidor de frecuencia integrado (IP55) para montaje en pared; variantes 2BH1640-1G356, 2BH1640-1GK46, 2BH1640-1GK56; tipos de convertidor de frecuencia A–K (2FC4...); accesorios MMI portátil, cable adaptador USB, sensores de presión/vacío.

Technical Data

Parameter Value Condición
Rated frequency 87 Hz p.2 ↗ 2BH1640-1G356, 380 V
Rated voltage 380 V p.2 ↗ 2BH1640-1G356
Rated current 27,4 A p.2 ↗ 2BH1640-1G356, 380 V
Rated motor power 14,0 kW p.2 ↗ 2BH1640-1G356, 380 V
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1640-1G356, 87 Hz
Max. differential pressure, pressure 190 mbar p.2 ↗ 2BH1640-1G356, 87 Hz
Sound pressure level 84 dB(A) p.2 ↗ 2BH1640-1G356, 87 Hz
Weight 109 kg p.2 ↗ 2BH1640-1G356
Rated frequency 50 Hz p.2 ↗ 2BH1640-1G356
Max. differential pressure, vacuum -240 mbar p.2 ↗ 2BH1640-1G356, 50 Hz
Max. differential pressure, pressure 260 mbar p.2 ↗ 2BH1640-1G356, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1640-1G356, 50 Hz
Rated frequency 60 Hz p.2 ↗ 2BH1640-1G356
Max. differential pressure, vacuum -210 mbar p.2 ↗ 2BH1640-1G356, 60 Hz
Max. differential pressure, pressure 200 mbar p.2 ↗ 2BH1640-1G356, 60 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH1640-1G356, 60 Hz
Rated voltage 400 V p.2 ↗ 2BH1640-1GK46, 87 Hz
Rated current 20,4 A p.2 ↗ 2BH1640-1GK46, 400 V
Rated motor power 10,2 kW p.2 ↗ 2BH1640-1GK46, 400 V
Max. differential pressure, vacuum -90 mbar p.2 ↗ 2BH1640-1GK46, 87 Hz
Max. differential pressure, pressure 70 mbar p.2 ↗ 2BH1640-1GK46, 87 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH1640-1GK46, 87 Hz
Rated voltage 400 D V p.2 ↗ 2BH1640-1GK56, 87 Hz
Rated current 26,0 D A p.2 ↗ 2BH1640-1GK56, 400 V
Rated motor power 14,0 kW p.2 ↗ 2BH1640-1GK56, 400 V

Operating Limits

  • Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH164 Series 2BH1, size 640 side channel blower
field after hyphen, 1 p.2 ↗ 1 Version index
field after hyphen, 2 p.2 ↗ G Motor/connection variant letter (G)
field after hyphen, 3 p.2 ↗ K Motor variant with frequency converter (K)
field after hyphen, 4-5 p.2 ↗ 35 / K4 / K5 Voltage/frequency variant: 35 = 380 V, 87 Hz; K4 = 400 V, 87 Hz; K5 = 400 V D, 87 Hz
field after hyphen, 6 p.2 ↗ 6 Frequency converter / motor option code

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1640-1G356 p.2 ↗ 2BH1640-1G356 G 380 V, 87 Hz Side channel blower with frequency converter
2BH1640-1GK46 p.2 ↗ 2BH1640-1GK46 3) 400 V, 87 Hz Footnote 3) in document
2BH1640-1GK56 p.2 ↗ 2BH1640-1GK56 3) 400 V D, 87 Hz Footnote 3) in document