Technical Data Sheet — G-BH1 2BH1690 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos del soplador de canal lateral 2BH1 690 (serie G-BH1), que abarca 2BH1690-1AH26 y 2BH1690-1AC23 con datos de 50 Hz y 60 Hz, además de variantes de motor de tensión alternativa seleccionables mediante el código de pedido 2BH1690-..□.□ (códigos de tensión 1, 3, 5, 6, 7 y códigos de eficiencia/motor C, H, K, Q).
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated pressure (vacuum) | -160 mbar p.2 ↗ | 2BH1690-1AH26, 50 Hz |
| Rated pressure (vacuum) | -240 mbar p.2 ↗ | 2BH1690-1AH26, 60 Hz |
| Max. differential pressure (pressure) | 200 mbar p.2 ↗ | 2BH1690-1AH26, 50 Hz |
| Max. differential pressure (pressure) | 250 mbar p.2 ↗ | 2BH1690-1AH26, 60 Hz |
| Voltage | 200-240 D / 345-415 Y V p.2 ↗ | 2BH1690-1AH26, 50 Hz |
| Voltage | 220-275 D / 380-480 Y V p.2 ↗ | 2BH1690-1AH26, 60 Hz |
| Current | 12,5 D / 7,2 Y A p.2 ↗ | 2BH1690-1AH26, 50 Hz |
| Current | 12,6 D / 7,3 Y A p.2 ↗ | 2BH1690-1AH26, 60 Hz |
| Power | 3,0 kW p.2 ↗ | 2BH1690-1AH26, 50 Hz |
| Power | 3,45 kW p.2 ↗ | 2BH1690-1AH26, 60 Hz |
| Noise level | 71 dB(A) p.2 ↗ | 2BH1690-1AH26, 50 Hz |
| Noise level | 75 dB(A) p.2 ↗ | 2BH1690-1AH26, 60 Hz |
| Weight | 37 kg p.2 ↗ | 2BH1690-1AH26 |
| Rated pressure (vacuum) | -160 mbar p.2 ↗ | 2BH1690-1AC23, 50 Hz |
| Rated pressure (vacuum) | -240 mbar p.2 ↗ | 2BH1690-1AC23, 60 Hz |
| Max. differential pressure (pressure) | 200 mbar p.2 ↗ | 2BH1690-1AC23, 50 Hz |
| Max. differential pressure (pressure) | 250 mbar p.2 ↗ | 2BH1690-1AC23, 60 Hz |
| Voltage | 500 Y V p.2 ↗ | 2BH1690-1AC23, 50 Hz |
| Current | 5,7 Y A p.2 ↗ | 2BH1690-1AC23, 50 Hz |
| Current | 5,8 Y A p.2 ↗ | 2BH1690-1AC23, 60 Hz |
| Power | 3,0 kW p.2 ↗ | 2BH1690-1AC23, 50 Hz |
| Power | 3,45 kW p.2 ↗ | 2BH1690-1AC23, 60 Hz |
| Noise level | 71 dB(A) p.2 ↗ | 2BH1690-1AC23, 50 Hz |
| Noise level | 75 dB(A) p.2 ↗ | 2BH1690-1AC23, 60 Hz |
| Weight | 37 kg p.2 ↗ | 2BH1690-1AC23 |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH1690 | Type/size designation of the side channel blower |
| field 1 p.2 ↗ | 1 | Motor variant / series field (as printed in 2BH1690-1...) |
| field 2 p.2 ↗ | A | Motor type field (as printed in 2BH1690-1A...) |
| field 3 p.2 ↗ | H / C | Efficiency/motor variant: H = standard efficiency, C = NEMA Premium/IE3 variant |
| field 4 p.2 ↗ | 2 | Voltage code: 200-240 D / 345-415 Y (50 Hz), 220-275 D / 380-480 Y (60 Hz) |
| field 4 p.2 ↗ | 3 | Voltage code: 500 Y (50 Hz), 575 Y (60 Hz) |
| field 4 p.2 ↗ | 5 | Voltage code: 500 D (50 Hz), 575 D (60 Hz) |
| field 4 p.2 ↗ | 6 | Voltage code: 200-240 / 345-415 Y (50 Hz), 220-275 / 380-480 Y (60 Hz), fixed 380 V at 87 Hz |
| field 4 p.2 ↗ | 7 | Voltage code: 345-415 D / 600-720 Y (50 Hz), 380-480 D / 660-720 Y (60 Hz), fixed 380 V at 87 Hz |
| field 4 p.2 ↗ | 1 | Voltage code: 185-225 D / 320-390 Y (50 Hz), 200-240 D / 345-415 Y (60 Hz), fixed 380 V at 87 Hz |
| field 5 p.2 ↗ | 1 / 3 / 5 / 6 / 7 | Second placeholder in 2BH1690-..□.□ selecting voltage range / efficiency variant combination |
Modelos relacionados
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943