Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1900 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 900: soplador de canal lateral con convertidor de frecuencia integrado (VFD). Abarca el tipo 2BH1 900 en las variantes 2BH1900-1A314, 2BH1900-1A324, 2BH1900-1AK16, 2BH1900-1AK26, 2BH1900-1AK36 (tipos de VFD H, K, G, J, K) y los convertidores de frecuencia correspondientes 2FC4xxx-1□□00 (tipos A–K) con adaptador de montaje en pared 2FX16190ER00.

Technical Data

Parameter Value Condición
Rated motor voltage 400 V p.2 ↗ 2BH1900-1A314, 72 Hz, U connection
Rated motor current 33,0 A p.2 ↗ 2BH1900-1A314, 72 Hz, U connection
Rated motor power 17,4 kW p.2 ↗ 2BH1900-1A314, 72 Hz
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1900-1A314, 72 Hz
Max. differential pressure, pressure 240 mbar p.2 ↗ 2BH1900-1A314, 72 Hz
Sound pressure level 82 dB(A) p.2 ↗ 2BH1900-1A314, 72 Hz
Weight 252 kg p.2 ↗ 2BH1900-1A314, 72 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1900-1A324, 72 Hz, U connection
Rated motor current 44,5 A p.2 ↗ 2BH1900-1A324, 72 Hz, U connection
Rated motor power 23,9 kW p.2 ↗ 2BH1900-1A324, 72 Hz
Max. differential pressure, vacuum -400 mbar p.2 ↗ 2BH1900-1A324, 72 Hz
Max. differential pressure, pressure 350 mbar p.2 ↗ 2BH1900-1A324, 72 Hz
Sound pressure level 82 dB(A) p.2 ↗ 2BH1900-1A324, 72 Hz
Weight 260 kg p.2 ↗ 2BH1900-1A324, 72 Hz
Rated motor voltage 330 V p.2 ↗ 2BH1900-1AK16, 72 Hz, D connection
Rated motor current 26,2 A p.2 ↗ 2BH1900-1AK16, 72 Hz, D connection
Rated motor power 11,7 kW p.2 ↗ 2BH1900-1AK16, 72 Hz
Max. differential pressure, vacuum -90 mbar p.2 ↗ 2BH1900-1AK16, 72 Hz
Max. differential pressure, pressure 80 mbar p.2 ↗ 2BH1900-1AK16, 72 Hz
Sound pressure level 82 dB(A) p.2 ↗ 2BH1900-1AK16, 72 Hz
Weight 234 kg p.2 ↗ 2BH1900-1AK16, 72 Hz
Rated motor voltage 330 V p.2 ↗ 2BH1900-1AK26, 72 Hz, D connection
Rated motor current 39,3 A p.2 ↗ 2BH1900-1AK26, 72 Hz, D connection
Rated motor power 17,4 kW p.2 ↗ 2BH1900-1AK26, 72 Hz
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1900-1AK26, 72 Hz

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Frequency converter rated mains voltage: 3~ 400 V -15% … 480 V +10% p.2 ↗
  • Frequency converter mains frequency: 50/60 Hz ±6% p.2 ↗
  • Frequency converter protection class: IP55 p.2 ↗
  • Motor protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1900 Type/size: side channel blower 2BH1 900
VFD type letter p.2 ↗ H / K / G / J / K VFD type assigned to the blower variant (H, K, G, J, K)
2FC4xxx-1□□00 field 1 p.2 ↗ A–K Frequency converter size/type letter
2FC4xxx-1□□00 field 2 p.2 ↗ □ Placeholder for voltage/connection variant of the frequency converter

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1900-1A314 p.2 ↗ 2BH1900-1A314 H 72 Hz, 400 V U connection, 17,4 kW VFD type H
2BH1900-1A324 p.2 ↗ 2BH1900-1A324 K 72 Hz, 400 V U connection, 23,9 kW VFD type K
2BH1900-1AK16 p.2 ↗ 2BH1900-1AK16 G 72 Hz, 330 V D connection, 11,7 kW VFD type G
2BH1900-1AK26 p.2 ↗ 2BH1900-1AK26 J 72 Hz, 330 V D connection, 17,4 kW VFD type J
2BH1900-1AK36 p.2 ↗ 2BH1900-1AK36 K 72 Hz, 330 V D connection, 23,9 kW VFD type K