Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — 2BH1940 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 940: soplador de canal lateral con motores IE3, tipo 2BH1940, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 (certificado E225239); variantes 1, 2, 3 con diferentes rangos de tensión (BK21/BK31/BK41, BK26/BK36/BK46, BQ23/BQ33/BQ43, BQ27/BQ37/BQ47)

Technical Data

Parameter Value Condición
Rated voltage 190-210 V p.2 ↗ 2BH1940-1BK21, 50 Hz, Δ
Rated current 63,1 A p.2 ↗ 2BH1940-1BK21, 50 Hz, Δ
Power 17,3 kW p.2 ↗ 2BH1940-1BK21, 50 Hz
Max. differential pressure vacuum -150 mbar p.2 ↗ 2BH1940-1BK21, 50 Hz
Max. differential pressure pressure 140 mbar p.2 ↗ 2BH1940-1BK21, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1940-1BK21, 50 Hz
Weight approx. 303 kg p.2 ↗ 2BH1940-1BK21
Efficiency class IE3 p.2 ↗ 2BH1940-1BK21, 50 Hz
Rated voltage 190-210 / 380-480 V p.2 ↗ 2BH1940-1BK21, 60 Hz, Δ/Y
Rated current 72,2 / 36,1 A p.2 ↗ 2BH1940-1BK21, 60 Hz, Δ/Y
Power 19,9 kW p.2 ↗ 2BH1940-1BK21, 60 Hz
Max. differential pressure vacuum -110 mbar p.2 ↗ 2BH1940-1BK21, 60 Hz
Max. differential pressure pressure 90 mbar p.2 ↗ 2BH1940-1BK21, 60 Hz
Sound pressure level 77 dB(A) p.2 ↗ 2BH1940-1BK21, 60 Hz
Rated voltage 220-240 / 380-420 V p.2 ↗ 2BH1940-1BK26, 50 Hz, Δ/Y
Rated current 48,5 / 31,7 A p.2 ↗ 2BH1940-1BK26, 50 Hz, Δ/Y
Power 17,3 kW p.2 ↗ 2BH1940-1BK26, 50 Hz
Max. differential pressure vacuum -150 mbar p.2 ↗ 2BH1940-1BK26, 50 Hz
Max. differential pressure pressure 140 mbar p.2 ↗ 2BH1940-1BK26, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1940-1BK26, 50 Hz
Weight approx. 303 kg p.2 ↗ 2BH1940-1BK26
Rated voltage 475-525 V p.2 ↗ 2BH1940-1BQ23, 50 Hz, Y
Rated current 25,4 A p.2 ↗ 2BH1940-1BQ23, 50 Hz, Y
Power 17,3 kW p.2 ↗ 2BH1940-1BQ23, 50 Hz
Max. differential pressure vacuum -150 mbar p.2 ↗ 2BH1940-1BQ23, 50 Hz

Operating Limits

  • Protection category: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗
  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH194 Type/series designation (side channel blower 2BH1, size 940)
8-9 p.2 ↗ 1B Motor/voltage variant group (BK, BQ)

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1940-1BK21 p.2 ↗ 2BH1940-1BK21 50 Hz, 190-210 V Δ; 60 Hz, 190-210 V Δ / 380-480 V Y Variant 1, IE3
2BH1940-1BK31 p.2 ↗ 2BH1940-1BK31 50 Hz, 190-210 V Δ; 60 Hz, 190-210 V Δ / 380-420 V Y Variant 2, IE3
2BH1940-1BK41 p.2 ↗ 2BH1940-1BK41 50 Hz, 190-210 V Δ; 60 Hz, 190-210 V Δ / 380-420 V Y Variant 3, IE3
2BH1940-1BK26 p.2 ↗ 2BH1940-1BK26 50 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz, 220-240 V Δ / 380-420 V Y Variant 1, IE3
2BH1940-1BK36 p.2 ↗ 2BH1940-1BK36 50 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz, 220-240 V Δ / 440-480 V Y Variant 2, IE3
2BH1940-1BK46 p.2 ↗ 2BH1940-1BK46 50 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz, 220-240 V Δ / 440-480 V Y Variant 3, IE3
2BH1940-1BQ23 p.2 ↗ 2BH1940-1BQ23 50 Hz, 475-525 V Y; 60 Hz, 550-600 V Y Variant 1, IE3
2BH1940-1BQ33 p.2 ↗ 2BH1940-1BQ33 50 Hz, 475-525 V Y; 60 Hz, 550-600 V Y Variant 2, IE3
2BH1940-1BQ43 p.2 ↗ 2BH1940-1BQ43 50 Hz, 475-525 V Y; 60 Hz, 550-600 V Y Variant 3, IE3
2BH1940-1BQ27 p.2 ↗ 2BH1940-1BQ27 50 Hz, 380-420 V Δ / 660-725 V Y; 60 Hz, 440-480 V Δ Variant 1, IE3

Modelos relacionados