Technical Data Sheet — 2BH741 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH7 410, soplador de canal lateral G-BH 7 N con motores IE3; abarca los tamaños 1 y 2 en variantes de 50 Hz y 60 Hz con múltiples opciones de conexión de tensión/frecuencia (190-210 V, 220-240 V, 380-420 V, 440-480 V, 500 V, 575 V, 460 V, 690 V) y números de pedido 2BH7410-0AK11-1, -0AK21-1, -0AK16-1, -0AK26-1, -0AQ13-1, -0AQ23-1, -0AQ16-1, -0AQ26-1, -0AQ17-1, -0AQ27-1
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Voltage | 190-210 V p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Current | 5,6 A p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Power consumption at pump shaft | 1,3 kW p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Ultimate pressure | -300 mbar p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Suction capacity | 390 m³/h p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Sound pressure level | 58 dB(A) p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Weight | 26 kg p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Efficiency class | IE3 p.2 ↗ | 2BH7410-0AK11-1, size 1, 50 Hz |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 2BH7410-0AK11-1, size 1, 60 Hz |
| Current | 6,3 A p.2 ↗ | 2BH7410-0AK11-1, size 1, 60 Hz |
| Power consumption at pump shaft | 1,6 kW p.2 ↗ | 2BH7410-0AK11-1, size 1, 60 Hz |
| Ultimate pressure | -350 mbar p.2 ↗ | 2BH7410-0AK11-1, size 1, 60 Hz |
| Suction capacity | 370 m³/h p.2 ↗ | 2BH7410-0AK11-1, size 1, 60 Hz |
| Sound pressure level | 63 dB(A) p.2 ↗ | 2BH7410-0AK11-1, size 1, 60 Hz |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Current | 6,9 A p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Power consumption at pump shaft | 1,8 kW p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Ultimate pressure | -310 mbar p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Suction capacity | 430 m³/h p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Sound pressure level | 63 dB(A) p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Weight | 29 kg p.2 ↗ | 2BH7410-0AK21-1, size 2, 50 Hz |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 2BH7410-0AK21-1, size 2, 60 Hz |
| Current | 7,8 A p.2 ↗ | 2BH7410-0AK21-1, size 2, 60 Hz |
| Power consumption at pump shaft | 2,0 kW p.2 ↗ | 2BH7410-0AK21-1, size 2, 60 Hz |
| Ultimate pressure | -370 mbar p.2 ↗ | 2BH7410-0AK21-1, size 2, 60 Hz |
Operating Limits
- Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH7410 | Type/size designation: G-BH 7 N side channel blower, size 410 |
| 8-9 p.2 ↗ | 0A | Motor/voltage variant family |
| Z field p.2 ↗ | Q3, Q5, Q6, Q7 | Voltage/frequency option substitution: Q3 = 475-525 V Y / 550-600 V Y; Q5 = 475-525 V D / 550-600 V D; Q6 = 220-240 V D / 380-420 V Y, 440-480 V Y; Q7 = 400 V D / 690 V Y, 460 V D |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH7410-0AK11-1 p.2 ↗ | 2BH7410-0AK11-1 | size 1, 190-210 V / 380-420 V, 50/60 Hz | IE3 | |
| 2BH7410-0AK21-1 p.2 ↗ | 2BH7410-0AK21-1 | size 2, 190-210 V / 380-420 V, 50/60 Hz | IE3 | |
| 2BH7410-0AK16-1 p.2 ↗ | 2BH7410-0AK16-1 | size 1, 220-240 V / 440-480 V, 50/60 Hz | IE3 | |
| 2BH7410-0AK26-1 p.2 ↗ | 2BH7410-0AK26-1 | size 2, 220-240 V / 440-480 V, 50/60 Hz | IE3 | |
| 2BH7410-0AQ13-1 p.2 ↗ | 2BH7410-0AQ13-1 | size 1, 500 V, 50/60 Hz | IE3 | |
| 2BH7410-0AQ23-1 p.2 ↗ | 2BH7410-0AQ23-1 | size 2, 500 V, 50/60 Hz | IE3 | |
| 2BH7410-0AQ16-1 p.2 ↗ | 2BH7410-0AQ16-1 | size 1, 220-240 V / 440-480 V, 50/60 Hz | IE3 | |
| 2BH7410-0AQ26-1 p.2 ↗ | 2BH7410-0AQ26-1 | size 2, 220-240 V / 440-480 V, 50/60 Hz | IE3 | |
| 2BH7410-0AQ17-1 p.2 ↗ | 2BH7410-0AQ17-1 | size 1, 380-420 V / 460 V, 50/60 Hz | IE3 | |