Technical Data Sheet — 2BH751 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH7 510, soplador de canal lateral G-BH 7 N con motores IE3. Abarca los tamaños 1 y 2 (variantes de 33 kg / 38 kg), 50 Hz y 60 Hz, diversas variantes de tensión (D, Y, YY, UU), versiones de motor IE3 y NP. Plantilla de código de pedido 2BH7…-..□.□-1.

Technical Data

Parameter Value Condición
Rated voltage 190-210 V p.2 ↗ 2BH7510-0AK11-1, 50 Hz, D
Rated current 6,9 A p.2 ↗ 2BH7510-0AK11-1, 50 Hz, D
Motor power 1,8 kW p.2 ↗ 2BH7510-0AK11-1, 50 Hz
Vacuum -310 mbar p.2 ↗ 2BH7510-0AK11-1, 50 Hz
Pressure 360 mbar p.2 ↗ 2BH7510-0AK11-1, 50 Hz
Sound level 62 dB(A) p.2 ↗ 2BH7510-0AK11-1, 50 Hz
Weight 33 kg p.2 ↗ 2BH7510-0AK11-1
Rated voltage 190-210 UU / 380-420 U V p.2 ↗ 2BH7510-0AK11-1, 60 Hz
Rated current 7,8 UU / 3,9 U A p.2 ↗ 2BH7510-0AK11-1, 60 Hz
Motor power 2,0 kW p.2 ↗ 2BH7510-0AK11-1, 60 Hz
Vacuum -340 mbar p.2 ↗ 2BH7510-0AK11-1, 60 Hz
Pressure 330 mbar p.2 ↗ 2BH7510-0AK11-1, 60 Hz
Sound level 68 dB(A) p.2 ↗ 2BH7510-0AK11-1, 60 Hz
Rated voltage 190-210 V p.2 ↗ 2BH7510-0AK21-1, 50 Hz, D
Rated current 9,9 A p.2 ↗ 2BH7510-0AK21-1, 50 Hz, D
Motor power 2,5 kW p.2 ↗ 2BH7510-0AK21-1, 50 Hz
Vacuum -310 mbar p.2 ↗ 2BH7510-0AK21-1, 50 Hz
Pressure 420 mbar p.2 ↗ 2BH7510-0AK21-1, 50 Hz
Sound level 62 dB(A) p.2 ↗ 2BH7510-0AK21-1, 50 Hz
Weight 38 kg p.2 ↗ 2BH7510-0AK21-1
Rated voltage 190-210 UU / 380-420 U V p.2 ↗ 2BH7510-0AK21-1, 60 Hz
Rated current 12,0 UU / 6,0 U A p.2 ↗ 2BH7510-0AK21-1, 60 Hz
Motor power 3,0 kW p.2 ↗ 2BH7510-0AK21-1, 60 Hz
Vacuum -370 mbar p.2 ↗ 2BH7510-0AK21-1, 60 Hz
Pressure 490 mbar p.2 ↗ 2BH7510-0AK21-1, 60 Hz

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series / type: side channel blower G-BH 7 N
5-8 p.2 ↗ 510 Size designation (2BH7 510)
field 1 p.2 ↗ 0 Fixed digit
field 2 p.2 ↗ A Motor variant / voltage family (A, Q)
field 3 p.2 ↗ K, Q Voltage code: K = 190-210 V; Q = 220-240/380-420 V or 475-525/550-600 V
field 4 p.2 ↗ 1, 2 Size / power stage: 1 = 1,8 kW (33 kg), 2 = 2,5 kW (38 kg)
field 5 p.2 ↗ 1, 3, 5, 6, 7 Voltage / connection variant (e.g. 1 = 190-210 V, 3 = 475-525 V Y, 5 = 475-525 V D, 6 = 220-240 V D / 380-420 V Y, 7 = 400 V D / 690 V Y)
suffix p.2 ↗ -1 Design variant

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH7510-0AK11-1 p.2 ↗ 2BH7510-0AK11-1 50/60 Hz, 190-210 V Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg
2BH7510-0AK21-1 p.2 ↗ 2BH7510-0AK21-1 50/60 Hz, 190-210 V Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg
2BH7510-0AK16-1 p.2 ↗ 2BH7510-0AK16-1 50/60 Hz, 220-240 V D / 380-420 V Y Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg
2BH7510-0AK26-1 p.2 ↗ 2BH7510-0AK26-1 50/60 Hz, 220-240 V D / 380-420 V Y Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg
2BH7510-0AQ13-1 p.2 ↗ 2BH7510-0AQ13-1 50/60 Hz, 500 V / 575 V Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg
2BH7510-0AQ23-1 p.2 ↗ 2BH7510-0AQ23-1 50/60 Hz, 500 V / 575 V Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg
2BH7510-0AQ16-1 p.2 ↗ 2BH7510-0AQ16-1 50/60 Hz Size 1, 33 kg
2BH7510-0AQ26-1 p.2 ↗ 2BH7510-0AQ26-1 50/60 Hz Size 2, 38 kg
2BH7510-0AQ17-1 p.2 ↗ 2BH7510-0AQ17-1 50/60 Hz, 380-420 V D / 460 V D Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg
2BH7510-0AQ27-1 p.2 ↗ 2BH7510-0AQ27-1 50/60 Hz, 380-420 V D / 460 V D Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg