Technical Data Sheet — G-BH7 2BH7520 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH7 520: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH7 520. Abarca el funcionamiento con VFD a 100 Hz (400 V, delta) tamaños 1-3 (n.os de pedido 2BH7520-0A321-1, -0A351-1, -0A371-1), las variantes de conexión directa a la red de 50/60 Hz (2BH7520-0AK26-1, -0AK56-1, -0AK76-1) y los tipos de VFD correspondientes A-K (2FC4...-1□□00).

Technical Data

Parameter Value Condición
Rated frequency 100 Hz p.2 ↗ 2BH7520-0A321-1, VFD operation
Rated voltage 400 V p.2 ↗ 2BH7520-0A321-1, VFD operation
Rated motor current 9,8 A p.2 ↗ 2BH7520-0A321-1, VFD operation
Rated motor power 5,0 kW p.2 ↗ 2BH7520-0A321-1, VFD operation
Max. differential pressure, vacuum -320 mbar p.2 ↗ 2BH7520-0A321-1, VFD operation
Max. differential pressure, pressure 240 mbar p.2 ↗ 2BH7520-0A321-1, VFD operation
Sound pressure level 77 dB(A) p.2 ↗ 2BH7520-0A321-1, VFD operation
Weight 57 kg p.2 ↗ 2BH7520-0A321-1, VFD operation
Rated motor current 12,7 A p.2 ↗ 2BH7520-0A351-1, VFD operation
Rated motor power 6,6 kW p.2 ↗ 2BH7520-0A351-1, VFD operation
Max. differential pressure, vacuum -520 mbar p.2 ↗ 2BH7520-0A351-1, VFD operation
Max. differential pressure, pressure 480 mbar p.2 ↗ 2BH7520-0A351-1, VFD operation
Sound pressure level 81 dB(A) p.2 ↗ 2BH7520-0A351-1, VFD operation
Rated motor current 16,2 A p.2 ↗ 2BH7520-0A371-1, VFD operation
Rated motor power 8,8 kW p.2 ↗ 2BH7520-0A371-1, VFD operation
Max. differential pressure, vacuum -560 mbar p.2 ↗ 2BH7520-0A371-1, VFD operation
Max. differential pressure, pressure 750 mbar p.2 ↗ 2BH7520-0A371-1, VFD operation
Sound pressure level 81 dB(A) p.2 ↗ 2BH7520-0A371-1, VFD operation
Weight 71 kg p.2 ↗ 2BH7520-0A371-1, VFD operation
Rated voltage 345 V p.2 ↗ 2BH7520-0AK26-1, 87 Hz, delta
Rated motor current 8,7 A p.2 ↗ 2BH7520-0AK26-1, 87 Hz, delta
Rated motor power 4,3 kW p.2 ↗ 2BH7520-0AK26-1, 87 Hz, delta
Max. differential pressure, vacuum -480 mbar p.2 ↗ 2BH7520-0AK26-1, 87 Hz, delta
Max. differential pressure, pressure 380 mbar p.2 ↗ 2BH7520-0AK26-1, 87 Hz, delta
Sound pressure level 77 dB(A) p.2 ↗ 2BH7520-0AK26-1, 87 Hz, delta

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converter: 380 V p.1 ↗
  • Min. pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH7520 Type / size designation (side channel blower 2BH7, size 520)
field 1 p.2 ↗ 0A / 0AK Motor / drive variant: 0A = VFD operation (100 Hz), 0AK = 50/60 Hz direct-on-line
field 2 p.2 ↗ 3 / 5 / 7 Size stage 1 / 2 / 3 (power and pressure class)
field 3 p.2 ↗ 2 / 5 / 6 Motor power variant within size stage
field 4 p.2 ↗ 1 Design / generation index
VFD type letter p.2 ↗ A … K Frequency converter type 2FC4...-1□□00 matched to blower size

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH7520-0A321-1 p.2 ↗ 2BH7520-0A321-1 E 100 Hz, 400 V, VFD operation VFD type E
2BH7520-0A351-1 p.2 ↗ 2BH7520-0A351-1 E 100 Hz, 400 V, VFD operation VFD type E
2BH7520-0A371-1 p.2 ↗ 2BH7520-0A371-1 F 100 Hz, 400 V, VFD operation VFD type F
2BH7520-0AK26-1 p.2 ↗ 2BH7520-0AK26-1 D 87 Hz, 345 V delta 50/60 Hz direct-on-line variant, footnote 3
2BH7520-0AK56-1 p.2 ↗ 2BH7520-0AK56-1 E 87 Hz, 400 V delta 50/60 Hz direct-on-line variant, footnote 3
2BH7520-0AK76-1 p.2 ↗ 2BH7520-0AK76-1 F 87 Hz, 400 V delta 50/60 Hz direct-on-line variant, footnote 3
2FC4402-1 p.2 ↗ 2FC4402-1 D VFD type D 9,5 A, 4,0 kW