Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH7 630-0N: soplador de canal lateral con convertidor de frecuencia integrado (VFD). Abarca el funcionamiento a 50 Hz y 60 Hz, redes de 400 V y 380 V, conexión en triángulo, tipos de VFD G y H, y números de pedido 2BH7630-0N361-2, -0N371-2, -0N366-2, -0N376-2, -0NK66-2, -0NK76-2.

Technical Data

Parameter Value Condición
Frequency 50 Hz p.2 ↗ 2BH7630-0N361-2, 400 V
Rated voltage 400 V p.2 ↗ 2BH7630-0N361-2, 50 Hz
Rated motor current 29,0 A p.2 ↗ 2BH7630-0N361-2, 50 Hz, 400 V
Rated motor power 16,0 kW p.2 ↗ 2BH7630-0N361-2, 50 Hz, 400 V
Max. differential pressure, vacuum -560 mbar p.2 ↗ 2BH7630-0N361-2, 50 Hz
Max. differential pressure, pressure 390 mbar p.2 ↗ 2BH7630-0N361-2, 50 Hz
Sound pressure level 80 dB(A) p.2 ↗ 2BH7630-0N361-2, 50 Hz
Weight 118 kg p.2 ↗ 2BH7630-0N361-2, 50 Hz
Frequency 100 Hz p.2 ↗ 2BH7630-0N361-2, 400 V
Rated motor current 22,0 A p.2 ↗ 2BH7630-0N371-2, 100 Hz, 400 V
Rated motor power 12,1 kW p.2 ↗ 2BH7630-0N371-2, 100 Hz, 400 V
Max. differential pressure, vacuum -560 mbar p.2 ↗ 2BH7630-0N371-2, 100 Hz
Max. differential pressure, pressure 320 mbar p.2 ↗ 2BH7630-0N371-2, 100 Hz
Sound pressure level 80 dB(A) p.2 ↗ 2BH7630-0N371-2, 100 Hz
Weight 110 kg p.2 ↗ 2BH7630-0N371-2, 100 Hz
Rated voltage 380 V p.2 ↗ 2BH7630-0N366-2, 85 Hz
Rated motor current 27,4 A p.2 ↗ 2BH7630-0N366-2, 85 Hz, 380 V
Rated motor power 14,0 kW p.2 ↗ 2BH7630-0N366-2, 85 Hz, 380 V
Max. differential pressure, vacuum -590 mbar p.2 ↗ 2BH7630-0N366-2, 85 Hz
Max. differential pressure, pressure 990 mbar p.2 ↗ 2BH7630-0N366-2, 85 Hz
Sound pressure level 80 dB(A) p.2 ↗ 2BH7630-0N366-2, 85 Hz
Weight 120 kg p.2 ↗ 2BH7630-0N366-2, 85 Hz
Rated voltage 400 V p.2 ↗ 2BH7630-0NK66-2, 85 Hz, delta
Rated motor current 26,0 A p.2 ↗ 2BH7630-0NK66-2, 85 Hz, 400 V delta
Rated motor power 14,0 kW p.2 ↗ 2BH7630-0NK66-2, 85 Hz, 400 V delta

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converter: 380 V p.1 ↗
  • Min. pulse frequency for performance curves: 4 kHz p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series G-BH7 side channel blower
5-8 p.2 ↗ 630-0N Size / type 2BH7 630-0N
suffix p.2 ↗ 361-2 Variant: 100 Hz, 400 V, VFD type H
suffix p.2 ↗ 371-2 Variant: 100 Hz, 400 V, VFD type G
suffix p.2 ↗ 366-2 Variant: 85 Hz, 380 V, VFD type G
suffix p.2 ↗ 376-2 Variant: 85 Hz, 380 V, VFD type G
suffix p.2 ↗ NK66-2 Variant: 85 Hz, 400 V delta, VFD type G
suffix p.2 ↗ NK76-2 Variant: 85 Hz, 400 V delta, VFD type G

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH7630-0N361-2 p.2 ↗ 2BH7630-0N361-2 H 100 Hz, 400 V VFD type H
2BH7630-0N371-2 p.2 ↗ 2BH7630-0N371-2 G 100 Hz, 400 V VFD type G
2BH7630-0N366-2 p.2 ↗ 2BH7630-0N366-2 G 85 Hz, 380 V VFD type G
2BH7630-0N376-2 p.2 ↗ 2BH7630-0N376-2 G 85 Hz, 380 V VFD type G
2BH7630-0NK66-2 p.2 ↗ 2BH7630-0NK66-2 G 85 Hz, 400 V delta VFD type G
2BH7630-0NK76-2 p.2 ↗ 2BH7630-0NK76-2 G 85 Hz, 400 V delta VFD type G