Technical Data Sheet — 2BH9230 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH92300: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH92300. Abarca funcionamiento a 50 Hz y 60 Hz, funcionamiento en vacío y en presión, descarga a la derecha (estándar) y descarga a la izquierda (opcional), y tipos de VFD A–K.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Frequency | 60 Hz p.2 ↗ | 2BH92300, 60 Hz |
| Rated voltage | 370 V p.2 ↗ | 2BH92300, 60 Hz |
| Current | 35,5 A p.2 ↗ | 2BH92300, 60 Hz |
| Power | 18,5 kW p.2 ↗ | 2BH92300, 60 Hz |
| Max. differential pressure, vacuum | -130 mbar p.2 ↗ | 2BH92300, 60 Hz |
| Max. differential pressure, pressure | 110 mbar p.2 ↗ | 2BH92300, 60 Hz |
| Sound pressure level | 81 dB(A) p.2 ↗ | 2BH92300, 60 Hz |
| Weight | 166 kg p.2 ↗ | 2BH92300, 60 Hz |
| Frequency | 60 Hz p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Rated voltage | 370 V p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Current | 24,5 A p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Max. differential pressure, vacuum | -190 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Max. differential pressure, pressure | 180 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Weight | 178 kg p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Frequency | 50 Hz p.2 ↗ | 2BH92300, 50 Hz |
| Max. differential pressure, vacuum | -190 mbar p.2 ↗ | 2BH92300, 50 Hz |
| Max. differential pressure, pressure | 170 mbar p.2 ↗ | 2BH92300, 50 Hz |
| Weight | 146 kg p.2 ↗ | 2BH92300, 50 Hz |
| Frequency | 60 Hz p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Rated voltage | 265 ∆ V p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Current | 55,5 ∆ A p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Power | 19,9 kW p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Max. differential pressure, vacuum | -150 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Max. differential pressure, pressure | 130 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Weight | 148 kg p.2 ↗ | 2BH92300, 50 Hz, VFD type A |
Operating Limits
- Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve reference air temperature: 15 °C p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-8 p.2 ↗ | 2BH92300 | Blower type / size designation |
| field 1 p.2 ↗ | 1 | Version / generation field |
| field 2 p.2 ↗ | AA | Motor / connection variant field |
| field 3 p.2 ↗ | Pxx | Placeholder for VFD type (A–K) |
| field 4 p.2 ↗ | AA | Discharge direction: AA = discharge right (standard); optional discharge left variant printed as 2BH9 2300-5AAPxx-AA |
| field 5 p.2 ↗ | Q2 / R2 / KQ6 / KR6 | Variant code of the selection table row |
| field 6 p.2 ↗ | BA | Suffix variant code |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH92300-1AA3Q2-BA p.2 ↗ | 2BH92300-1AA3Q2-BA | J | 60 Hz, VFD type J | |
| 2BH92300-1AA3R2-BA p.2 ↗ | 2BH92300-1AA3R2-BA | 60 Hz | ||
| 2BH92300-1AAKQ6-BA p.2 ↗ | 2BH92300-1AAKQ6-BA | 50 Hz | footnote 3) | |
| 2BH92300-1AAKR6-BA p.2 ↗ | 2BH92300-1AAKR6-BA | 50 Hz | footnote 3) |