CC-106A Immersion Circulator Datasheet

Contenido

  1. Overview p. 1
    Product introduction and main features of CC-106A
  2. Spec pp. 1-2
    Technical data according to DIN 12876
  3. p. 1 table, 34 rows

Technical data according to DIN 12876

ParameterValue
Operating temperature range25...100 °C
with water cooling20...100 °C
with refrigerator15...100 °C
Temperature stability at 70°C0,02 K
temperature set point / display5,7" colour Touchscreen
Absolute accuracysetup for calibration
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power at 240V2,1 kW
Heating power at 230V2 kW
Heating power at 220V1,8 kW
Heating power at 208V1,6 kW
Heating power at 200V1,5 kW
Pressure pump max. delivery27 l/min
max. delivery pressure0,7 bar
Suction pumpyes
max. delivery (suction)22 l/min
max. delivery pressure (suction)0,4 bar
Pump connenction (optional)M16x1 male
Bath volume4,4 l
min. filling capacity2,5 l
Width bath opening WxD/ bath depth130x110/ 150 mm
Overall dimensions WxDxH **147x307x330 mm
Net weight5 kg
Power supply requirement200-240V 1~/2~ 50/60Hz
max. current10 A
min. Fuse10A
max. Fuse16A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C

** Overall dimensions WxDxH

Engineering Facts

14 facts · every claim linked to a page
Selection

The operating temperature range depends on the cooling method, so the choice of water cooling or refrigerator must match the required process temperature.

Determines whether the bath can reach the required low temperatures and which cooling option must be specified.

Source
“Operating temperature range 25...100 °C with water cooling 20...100 °C with refrigerator 15...100 °C”
Installation

The unit requires a 200–240 V single- or two-phase supply with a minimum 10 A fuse, which must be provided at the installation site.

Needed to size the branch circuit and protective device correctly before installation.

Source
“Power supply requirement 200-240V 1~/2~ 50/60Hz max. current 10 A min. Fuse 10A max. Fuse 16A”
Installation

External branch circuit protection according to UL 489 is required, so a suitable UL-listed breaker must be included in the installation.

Affects the electrical installation design and compliance with UL requirements.

Source
“External branch circuit protection according to UL 489 required.”
Installation

Voltage and frequency tolerances are interdependent, so a −10% voltage combined with +3% frequency is not permitted.

Prevents installation on a supply where combined voltage and frequency deviations exceed the allowed envelope.

Source
“Example: -10% voltage and +3% frequency -> not allowed !”
Installation

Single- and two-phase devices are delivered with a country-specific plug that must be specified at ordering.

Ensures the correct mains plug is supplied and avoids rework at commissioning.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Operation

The ambient temperature must stay between 5 °C and 40 °C for correct operation.

Defines the permissible room conditions where the circulator may be installed and operated.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Operation

The bath must be filled with at least 2.5 l, which sets the minimum heat transfer fluid charge.

Prevents operation with insufficient fluid and ensures proper pump and heating behaviour.

Source
“min. filling capacity 2,5 l”
Operation

Polyglycol must not be used as heat transfer fluid when the Huber pump adapter is fitted.

Avoids selecting an incompatible fluid that could damage the pump adapter or system.

Source
“When using Huber pump adapter: Polyglycol is not permissible to be used as a heat transfer fluid”
Safety

The unit has adjustable overtemperature protection according to DIN 12876, which must be set for the application.

Provides the required safety cut-out and must be configured correctly during commissioning.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Safety

The safety classification is III / FL according to DIN 12876, which defines the protection concept for flammable liquids.

Determines whether the bath is suitable for the intended safety category and fluid.

Source
“Safety classification III / FL”
Performance

The pressure pump delivers up to 27 l/min at 0.7 bar, which sets the maximum external circuit flow capability.

Used to check whether the pump can supply the required flow and pressure in the external loop.

Source
“max. delivery 27 l/min max. delivery pressure 0,7 bar”
Performance

Heating power depends on the supply voltage, ranging from 1.5 kW at 200 V to 2.1 kW at 240 V.

Affects heat-up time and must be considered when sizing the electrical supply.

Source
“Heating power at 240V 2,1 kW Heating power at 230V 2 kW Heating power at 220V 1,8 kW Heating power at 208V 1,6 kW Heating power at 200V 1,5 kW”
Cumplimiento

The equipment is classified as Class A, Group 1 for electromagnetic disturbance to EN55011, which has implications for the installation environment.

Class A equipment may require additional EMC measures in residential or sensitive environments.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Maintenance

The 4-year warranty requires registration, so the registration must be completed to secure the extended coverage.

Affects the warranty claim process and should be handled at commissioning.

Source
“4-year warranty - registration required.”