Unichiller 100T-H Datasheet

Contenido

  1. Overview p. 1
    Product introduction and main features of the chiller
  2. Spec pp. 1-2
    Technical data, performance and operating parameters
  3. Spec p. 2
    Detailed values according to DIN 12876 standard
  4. p. 2 table, 10 rows
  5. p. 1 table, 33 rows

Technical data according to DIN 12876

ParameterValue
Overall dimensions WxDxH **600x790x1614 mm
Net weight284 kg
Power supply (3 Phase)400V 3~ 50Hz
max. current (3 Phase)16 A
Fuse (3 phase)3x25A
Pressure equipment categoryI
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S479767

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876

CharacteristicValue
Operating temperature range-20...100 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
Temperature stability at -10°C0,2 K
Safety classificationIII / FL
Heating power2 kW
Cooling power at 15°C10 kW
Cooling power at 0°C9 kW
Cooling power at -10°C6,5 kW
Cooling power at -20°C3 kW
Refrigeration machineair-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Refrigerant quantity4 kg
CO2 equivalent5,6 t
Circulation pumpC3
max. delivery96 l/min
max. delivery pressure5,6 bar
Delivery at 0,5 bar92 l/min
Delivery at 1,0 bar86 l/min
Delivery at 1,5 bar81 l/min
Delivery at 2,0 bar75 l/min
Delivery at 2,5 bar68 l/min
Delivery at 3,0 bar62 l/min
Delivery at 3,5 bar54 l/min
Delivery at 4,0 bar46 l/min
Delivery at 4,5 bar37 l/min
Delivery at 5,0 bar24 l/min
Pump connectionG1 1/4 male
min. filling capacity8,36 l
Volume of expansion7 l

Order-No.: 3017.0030.01; Unichiller 100T-H

Engineering Facts

14 facts · every claim linked to a page
Installation

The chiller requires a 400 V three-phase 50 Hz supply with a 16 A maximum current and 3x25 A fusing, so the electrical installation must be sized accordingly.

Determines the site power supply, cable cross-section and breaker rating needed before installation.

Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation

Three-phase devices drawing less than 63 A are delivered with a cable but without a plug, so the customer must provide and fit the plug on site.

Affects electrical installation planning and the bill of materials for commissioning.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation

Voltage and frequency tolerances are only valid in combination, and a -5% voltage with +2% frequency is explicitly not allowed.

Prevents connecting the unit to a marginal grid where combined tolerances could damage the compressor or electronics.

Source
“-5% voltage and +2% frequency -> not allowed!”
Installation

The unit is rated IP20, so it must be installed in a dry, protected location and not exposed to water or dust ingress.

Restricts the installation environment and rules out washdown or outdoor siting.

Source
“Degree of Protection IP20”
Installation

Ambient temperature must stay between 5 °C and 40 °C, and cooling capacity may drop if the ambient temperature rises above the rated 20 °C.

Needs to be checked against the room ventilation and heat load at the installation site to avoid derating.

Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Selection

Cooling capacity falls from 10 kW at 15 °C to 3 kW at -20 °C, so the required duty point must be checked against the capacity curve, not just the headline 10 kW.

Prevents oversizing or undersizing when the process runs at low temperatures.

Source
“at 15°C 10 kW”
Selection

The circulation pump delivers 96 l/min at zero head but only 24 l/min at 5.0 bar, so the system pressure drop must be matched to the pump curve.

Ensures the external circuit resistance does not starve flow at the required duty point.

Source
“max. delivery pressure 5,6 bar”
Installation

The pump connection is G1 1/4 male, so hoses and adapters must match this thread size.

Determines the fittings and hoses to procure for the external circuit.

Source
“Pump connection G1 1/4 male”
Operation

The minimum filling capacity is 8.36 l and the expansion volume is 7 l, so the external loop plus unit must be charged with sufficient heat transfer fluid.

Avoids cavitation and low-level alarms by ensuring adequate fluid volume at commissioning.

Source
“min. filling capacity 8,36 l”
Safety

The refrigerant is R-449A with GHS classification H280 and a GWP of 1397, giving a CO2 equivalent of 5.6 t that must be considered for leak detection and F-gas reporting.

Triggers F-gas obligations, room ventilation requirements and leak-check intervals.

Source
“Refrigerant (ASHRAE, GHS) R-449A (A1, H280)”
Safety

The unit has adjustable overtemperature protection according to DIN 12876 and safety classification III/FL, which must be set for the application.

The protection limit must be configured to protect the process and the fluid from overheating.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Cumplimiento

The equipment is EMC class A group 1, so it is intended for industrial environments and may cause interference in residential areas.

Affects siting and shielding decisions when sensitive electronics are nearby.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Maintenance

The refrigeration machine is air-cooled, so the condenser needs unobstructed airflow and periodic cleaning.

Poor airflow causes capacity loss and high-pressure trips; maintenance access must be planned.

Source
“Refrigeration machine air-cooled, CFC- and HCFC-free”
Installation

The overall dimensions are 600x790x1614 mm and the net weight is 284 kg, so floor loading and access routes must be verified.

Determines rigging, doorway clearance and floor point loading at the installation site.

Source
“Overall dimensions WxDxH ** 600x790x1614 mm”