Product introduction and key features of the chiller
Specpp. 1-2
Technical data and performance specifications per DIN 12876
p. 2table, 8 rows
p. 1table, 38 rows
Technical data according to DIN 12876
Parameter
Value
Power supply requirement
220-240V 1~ 50Hz
max. current
8,5 A
Fuse
16 A
Pressure equipment category
Art. 4.3 PED
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
S596204
Technical data according to DIN 12876
Parameter
Value
Operating temperature range
-20...40 °C
temperature set point / display
digital
Internal temperature sensor
Pt100
Resolution of display
0,1 K
Interface digital
USB (Device), RS232
Interface
Temperature stability at -10°C
0,5 K
Alarm message
optic, acoustic
Safety classification
I / NFL
Cooling power at 15°C
1,5 kW
Cooling power at 0°C
1 kW
Cooling power at -10°C
0,7 kW
Cooling power at -20°C
0,3 kW
Refrigeration machine
water-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)
R-290 (A3, H220)
Global Warming Potential (GWP)
0,02
Refrigerant quantity
0,99 kg
CO2 equivalent
0,0 t
Circulation pump
B
at 0,5 bar
21 l/min
at 1,0 bar
17 l/min
at 1,5 bar
11 l/min
at 2,0 bar
6 l/min
max. delivery
25 l/min
max. delivery pressure
2,5 bar
Pump connection
G3/4 male
Consumption at water 15°C, flow 15°C
68 l/h
Consumption at water 15°C, flow 0°C
60 l/h
Consumption at water 15°C, flow -10°C
48 l/h
Consumption at water 15°C, flow -20°C
36 l/h
Cooling water connection
G1/2 male
min. cooling water differential pressure
1 bar
max. cooling water pressure
6 bar
min. filling capacity
3,8 l
expansion tank
1,7 l
Overall dimensions WxDxH **
350x496x622 mm
Net weight
55 kg
sound pressure level +/- 4 dB(A)
54 dB(A)
** Overall dimensions WxDxH
Engineering Facts
14 facts · every claim linked to a page
Installation
The chiller requires cooling water with a minimum differential pressure of 1 bar and a maximum pressure of 6 bar, so the site water supply must be sized accordingly.
To verify the available cooling water supply meets the minimum pressure for proper operation and does not exceed the maximum pressure rating.
Source
“min. cooling water differential pressure 1 bar”
Installation
The unit is water-cooled and must be connected to a cooling water circuit with G1/2 male connections, and the cooling water intake temperature must be between 5°C and 20°C.
To ensure the cooling water supply temperature and connection type match the unit's requirements and avoid condensation or performance loss.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation
If cooling water temperature falls below the condensation point, the cooling water pipes in the unit must be insulated.
To prevent condensation and potential damage when using cold cooling water.
Source
“When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Performance
Cooling power drops as cooling water temperature increases, and the cooling water flow rate may need to be increased.
To account for reduced cooling capacity and higher water consumption when the available cooling water is warmer than the rated 15°C.
Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Safety
The refrigerant is R-290 (propane, A3, H220), a flammable natural refrigerant, so appropriate safety measures for flammable refrigerants are required.
To ensure the installation location and safety concept account for the flammability of the refrigerant.
Source
“R-290 (A3, H220)”
Operation
The plastic pump is not resistant to acetone and polyglycols, so these fluids must not be used; water with glysantine or ethylene glycol is recommended for freeze protection.
To select a compatible heat transfer fluid and avoid damaging the pump.
Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation
The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only suitable cooling water may be used.
To assess corrosion and compatibility of the site cooling water with the wetted materials.
Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Installation
The unit requires a 220-240V 1~ 50Hz power supply with a maximum current of 8.5 A and a 16 A fuse.
To size the electrical supply and protection for the installation.
Source
“max. current 8,5 A”
Installation
The unit has IP20 protection and must be operated in ambient temperatures between 5°C and 40°C.
To ensure the installation location meets the environmental and ingress protection requirements.
Source
“min. ambient temperature 5 °C”
Installation
Voltage and frequency tolerances are ±5% and ±2% respectively, but a -5% voltage combined with +2% frequency is not allowed.
To verify the site power quality stays within the allowed combined voltage and frequency tolerance.
Source
“-5% voltage and +2% frequency -> not allowed!”
Cumplimiento
The equipment is classified as Class A, Group 1 for electromagnetic disturbance according to EN55011.
To assess EMC compatibility and potential interference in the installation environment.
Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Selection
The minimum filling capacity is 3.8 l and the expansion tank volume is 1.7 l, which must be considered when sizing the external circuit.
To ensure the external loop and fluid volume are compatible with the unit's expansion tank and minimum fill.
Source
“min. filling capacity 3,8 l”
Installation
The pump connections are G3/4 male, and the unit includes hose couplings for G3/4 male and G1/2 male.
To prepare matching hoses and fittings for the process and cooling water connections.
Source
“Pump connection G3/4 male”
Operation
The OLÉ controller has an autostart function for power failure, so the unit may restart automatically after power is restored.
To plan for automatic restart behavior and associated safety considerations after a power interruption.