Unichiller P100w-H Datasheet

Contenido

  1. Overview p. 1
    Product introduction and main features of the chiller
  2. Spec pp. 1-2
    Technical data and performance parameters per DIN 12876
  3. p. 2 table, 20 rows
  4. p. 1 table, 31 rows

Technical data according to DIN 12876

ParameterValue
Cooling water connectionG1/2 male
Consumption at water 15°C, flow 20°C348 l/h
Consumption at water 15°C, flow 0°C330 l/h
Consumption at water 15°C, flow -10°C270 l/h
Consumption at water 15°C, flow -20°C240 l/h
min. cooling water differential pressure0,5 bar
max. cooling water pressure6 bar
min. filling capacity18 l
Volume of expansion48 l
Overall dimensions WxDxH **740x1160x1050 mm
Net weight321 kg
sound pressure level +/- 4 dB(A)58 dB(A)
Power supply (3 Phase)400V 3~ 50Hz
max. current (3 Phase)15,5 A
Fuse (3 phase)3x16A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S432091

** Please respect space requirements. See operating conditions at www.huber-online.com

Unichiller P100w-H — Technical data according to DIN 12876

ParameterValue
Order-No.3059.0012.01
Operating temperature range-20...100 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Temperature stability at -10°C0,2 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power2 kW
Cooling power at ambient temperature +20°C at 100°C10 kW
Cooling power at ambient temperature +20°C at 20°C10 kW
Cooling power at ambient temperature +20°C at 0°C7,8 kW
Cooling power at ambient temperature +20°C at -10°C5,3 kW
Cooling power at ambient temperature +20°C at -20°C3,1 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Refrigerant quantity1 kg
CO2 equivalent1,4 t
Circulation pumpE2
max. delivery130 l/min
max. delivery pressure5,7 bar
Delivery at 2,4 bar116 l/min
Delivery at 2,5 bar115 l/min
Delivery at 3,0 bar108 l/min
Delivery at 3,5 bar100 l/min
Delivery at 4,0 bar92 l/min
Delivery at 4,5 bar80 l/min
Delivery at 5,0 bar59 l/min
Delivery at 5,5 bar20 l/min
Pump connectionG1 1/4 male

Engineering Facts

12 facts · every claim linked to a page
Installation

The chiller requires a three-phase 400 V supply with a 3x16 A fuse and draws up to 15.5 A, so the site electrical supply must be sized accordingly.

Determines the electrical installation, cable and protection device rating before the unit can be commissioned.

Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation

The unit is water-cooled and needs a cooling water connection of G1/2 male with a minimum differential pressure of 0.5 bar and maximum pressure of 6 bar.

The cooling water circuit must be designed to deliver adequate flow and pressure without exceeding the unit's limits.

Source
“min. cooling water differential pressure 0,5 bar”
Operation

Cooling water inlet temperature must stay between 5 °C and 20 °C; below the condensation point the cooling water pipes inside the unit must be insulated.

Operating outside this range risks condensation, reduced cooling power or equipment damage.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance

Cooling power drops as cooling water temperature rises, and the required cooling water flow rate may increase, so performance must be derated for warmer water.

Selection must account for actual site cooling water temperature to avoid insufficient cooling capacity.

Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Installation

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Water quality and treatment must be compatible with these materials to prevent corrosion and fouling.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Cumplimiento

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed.

The site power quality must be verified against these combined tolerances to avoid invalid operating conditions.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation

Three-phase devices drawing less than 63 A are supplied with a cable but without a plug, so a suitable plug must be provided on site.

The installer must plan for a matching plug and connection point before commissioning.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Safety

The refrigerant is R-449A with GHS classification H280 and a GWP of 1397, with 1 kg charge equal to 1.4 t CO2 equivalent.

Affects refrigerant handling, leak detection and environmental reporting obligations.

Source
“R-449A (A1, H280)”
Operation

The unit is rated for ambient temperatures from 5 °C to 40 °C and has IP20 protection, so it must be installed in a dry indoor environment.

Site ambient conditions and ingress protection constrain where the chiller can be located.

Source
“max. ambient temperature 40 °C”
Installation

The unit weighs 321 kg and measures 740x1160x1050 mm, and space requirements must be respected.

Floor loading, access routes and clearance for installation and maintenance must be planned.

Source
“Please respect space requirements.”
Operation

The pump delivers up to 130 l/min at 5.7 bar but only 20 l/min at 5.5 bar, so system pressure drop must be checked against the pump curve.

High-pressure-drop applications must be evaluated to ensure adequate flow is available.

Source
“max. delivery pressure 5,7 bar”
Maintenance

The minimum filling capacity is 18 l and expansion volume is 48 l, which must be considered when preparing the heat transfer circuit.

Determines the required volume of heat transfer fluid and expansion tank sizing.

Source
“min. filling capacity 18 l”