Unimotive 10w-XT Immersion Circulator

Contenido

  1. Overview p. 1
    Introduces the Unimotive 10w-XT immersion circulator and its main features
  2. Spec pp. 1-2
    Performance, temperature, electrical and physical specifications per DIN 12876
  3. p. 2 table, 22 rows
  4. p. 1 table, 26 rows

Technical data according to DIN 12876

ParameterValue
Delivery at 1,0 bar179 l/min
Delivery at 2,0 bar154 l/min
Delivery at 3,0 bar124 l/min
Delivery at 4,0 bar87 l/min
Delivery at 5,0 bar42 l/min
Pump connectionM38x1,5 male
max. permissible kin. viscosity200 mm²/s
Cooling water connectionG3/4 male
Consumption at water 15°C, flow 0°C620 l/h
min. cooling water differential pressure1 bar
max. cooling water differential pressure4 bar
max. cooling water pressure6 bar
max. System pressure12 bar
min. filling capacity8,2 l
Filling capacity expansion tank19,9 l
Overall dimensions WxDxH **730x804x1738 mm
Power supply requirement400V 3~ 50Hz
Pressure equipment categoryI
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:1.0/23

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876

CharacteristicValue
Operating temperature range-45...150 °C
Temperature stability at -10°C0,05 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Interface analogoptional
Alarm messageoptic, acoustic, relay
Safety classificationI / NFL
Heating power12 kW
Cooling power with Water/ Glysantin 40/60 at 20°C14 kW
Cooling power with Water/ Glysantin 40/60 at 0°C10 kW
at -20°C5 kW
at -30°C2,1 kW
at -40°C0,8 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-452A (A1, H280)
Global Warming Potential (GWP)2141
Refrigerant quantity2,9 kg
CO2 equivalent6,2 t
Circulation pump: MK pump
max. delivery201 l/min
max. delivery pressure5,3 bar

Engineering Facts

13 facts · every claim linked to a page
Selection

The unit is designed for water-ethylene glycol mixtures with corrosion protection down to -45°C, so the heat transfer fluid must match this chemistry.

Determines whether the unit suits the intended automotive test fluid and prevents corrosion or freezing issues.

Source
“constructed for operation with Water-ethylene glycol mixture incl. corrosion protection (for example Glysantin®) down to -45°C”
Installation

Cooling water must be supplied between 5°C and 20°C, and pipes must be insulated if water temperature can drop below the condensation point.

Defines the facility cooling water requirements and condensation protection needed at installation.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation

The cooling water circuit requires a differential pressure between 1 bar and 4 bar, with a maximum supply pressure of 6 bar.

Ensures the site cooling water supply can meet the unit's hydraulic requirements without overpressure.

Source
“min. cooling water differential pressure 1 bar max. cooling water differential pressure 4 bar max. cooling water pressure 6 bar”
Installation

The unit requires a 400 V three-phase 50 Hz supply and is delivered without a plug for three-phase devices below 63 A.

The electrician must provide a suitable 400 V 3~ supply and a matching plug/connection on site.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation

Voltage and frequency tolerances are ±5% and ±2% respectively, but the combination of -5% voltage with +2% frequency is not allowed.

Prevents commissioning on a supply where the combined voltage/frequency deviation exceeds the permitted envelope.

Source
“-5% voltage and +2% frequency -> not allowed!”
Safety

Leakage current exceeds 3.5 mA, which affects protective earthing and RCD selection.

Requires appropriate earthing and possibly a type-B or higher-rated RCD for safe operation.

Source
“Attention: leakage current > 3,5mA”
Safety

The refrigerant R-452A is classified A1 with GHS hazard H280, and the charge is 2.9 kg corresponding to 6.2 t CO2 equivalent.

Affects refrigerant handling, leak detection, and F-gas reporting obligations.

Source
“R-452A (A1, H280)”
Operation

Cooling capacity drops significantly at low temperatures, from 14 kW at 20°C to 0.8 kW at -40°C.

The process heat load at low temperature must be checked against this reduced capacity.

Source
“at -40°C 0,8 kW”
Operation

The pump delivers 201 l/min maximum, but flow falls with pressure, e.g. 42 l/min at 5.0 bar.

The external circuit pressure drop determines the achievable flow and must be matched to the application.

Source
“Delivery at 5,0 bar 42 l/min”
Operation

The maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s.

Prevents pump overload or poor circulation when using viscous fluids at low temperature.

Source
“max. permissible kin. viscosity 200 mm²/s”
Operation

The unit must be operated within an ambient temperature range of 5°C to 40°C.

Defines the allowable room conditions for reliable operation and cooling performance.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Maintenance

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Guides water quality and treatment to avoid corrosion and fouling of the cooling circuit.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Cumplimiento

The equipment is classified as EN 55011 Class A Group 1, which has implications for use in residential environments.

Class A equipment may cause radio interference and is not intended for residential use without mitigation.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”