Unimotive 20w-XT Technical Data

Contenido

  1. Overview p. 1
    Product introduction and general description of the unit
  2. Spec p. 2
    Technical data according to DIN 12876
  3. p. 2 table, 25 rows
  4. p. 1 table, 26 rows

Technical data according to DIN 12876

ParameterValue
Delivery at 1,0 bar179 l/min
Delivery at 2,0 bar154 l/min
Delivery at 3,0 bar124 l/min
Delivery at 4,0 bar87 l/min
Delivery at 5,0 bar42 l/min
Pump connectionM38x1,5 male
max. permissible kin. viscosity200 mm²/s
Cooling water connectionG3/4 male
Consumption at water 15°C, flow 0°C920 l/h
min. cooling water differential pressure1 bar
max. cooling water differential pressure4 bar
max. cooling water pressure6 bar
max. System pressure12 bar
min. filling capacity8,2 l
Filling capacity expansion tank19,9 l
Overall dimensions WxDxH **730x804x1738 mm
Net weight466 kg
Power supply requirement400V 3~ 50Hz
max. current35 A
Fuse3x40A
Pressure equipment categoryI
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S552631

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876

ParameterValue
Operating temperature range-45...150 °C
Temperature stability at -10°C0,05 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Interface analogoptional
Alarm messageoptic, acoustic, relay
Safety classificationI / NFL
Heating power12 kW
Cooling power with Water/ Glysantin 40/60 at 20°C21 kW
Cooling power with Water/ Glysantin 40/60 at 0°C17,5 kW
at -20°C9,5 kW
at -30°C5,5 kW
at -40°C3 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-452A (A1, H280)
Global Warming Potential (GWP)2141
Refrigerant quantity2,9 kg
CO2 equivalent6,2 t
Circulation pump:MK pump
max. delivery201 l/min
max. delivery pressure5,3 bar

Engineering Facts

14 facts · every claim linked to a page
Selection

The unit is designed for water-ethylene glycol mixtures with corrosion protection down to -45°C, so it suits automotive temperature simulation and material testing rather than general lab use.

Confirms the intended heat transfer fluid and application envelope before specifying the unit.

Source
“The temperature control systems are constructed for operation with Water-ethylene glycol mixture incl. corrosion protection (for example Glysantin®) down to -45°C.”
Installation

The cooling water supply must be between 5°C and 20°C, and pipes must be insulated if the water temperature can drop below the dew point.

Defines the facility cooling water requirements and condensation protection needed at installation.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation

Cooling water differential pressure must stay between 1 bar and 4 bar, with a maximum supply pressure of 6 bar.

Ensures the site cooling water loop can deliver adequate flow without overpressurizing the unit.

Source
“min. cooling water differential pressure 1 bar”
Installation

The unit requires a 400 V three-phase 50 Hz supply with a maximum current of 35 A and 3x40 A fusing.

Determines electrical supply, breaker sizing and cable planning for the installation.

Source
“Power supply requirement 400V 3~ 50Hz”
Installation

Three-phase devices below 63 A are delivered with a cable but without a plug, so the site must provide a suitable connection.

Avoids surprises at commissioning regarding the missing mains plug.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Safety

Leakage current exceeds 3.5 mA, which affects residual current device selection and earthing requirements.

Must be considered when specifying RCDs and protective earthing for the installation.

Source
“Attention: leakage current > 3,5mA”
Operation

The unit is rated IP20 and must be operated between 5°C and 40°C ambient, so it needs a clean, temperature-controlled indoor location.

Restricts installation environment and prevents operation in wet or dusty areas.

Source
“Degree of Protection IP20”
Performance

Cooling capacity falls from 21 kW at 20°C to 3 kW at -40°C, so low-temperature duty must be sized against the actual operating point.

Prevents oversizing assumptions based on nominal capacity when running cold.

Source
“at -40°C 3 kW”
Performance

Cooling capacity data are valid only at 20°C room temperature, 15°C cooling water inlet and 1 bar differential pressure.

Defines the reference conditions against which quoted capacities must be corrected for the site.

Source
“Output data valid for: Room temperature 20°C, cooling water inlet 15°C and 1 bar differential pressure between cooling water inlet and -outlet.”
Operation

The pump delivers 201 l/min at zero head but only 42 l/min at 5 bar, so system pressure drop directly limits achievable flow.

Needed to match the external circuit pressure drop to the available pump curve.

Source
“max. delivery 201 l/min”
Operation

Maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s, which limits how cold or viscous the fluid may be.

Constrains fluid selection and the lowest practical operating temperature.

Source
“max. permissible kin. viscosity 200 mm²/s”
Installation

The unit needs at least 8.2 l filling capacity and has a 19.9 l expansion tank, so the external loop volume must be planned accordingly.

Determines minimum fluid charge and expansion volume for the external circuit.

Source
“min. filling capacity 8,2 l”
Cumplimiento

Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.

Must be checked against the site power quality before commissioning.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Cumplimiento

The unit is EMC Class A Group 1, so it is intended for industrial environments and may cause interference in residential areas.

Affects installation location and EMC planning in mixed-use facilities.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”