Environmental, conformity and utility requirements
Procedurepp. 7-8
Steps to prepare pump for installation
Overviewpp. 9-10
Intended use and operating limits
Specpp. 11-12
Technical data and specifications
pp. 13-38
Full manual translated into Italian
pp. 39-62
Full manual translated into German
pp. 63-88
Full manual translated into French
pp. 89-112
Full manual translated into Spanish
pp. 113-138
Full manual translated into Traditional Chinese
pp. 139-162
Full manual translated into Japanese
pp. 163-186
Full manual in English
Specpp. 187-190
Detailed technical data and specifications
Specpp. 191-192
Dimensional outline drawing of pump
Specpp. 193-194
Pumping speed and performance curves
Procedurepp. 195-196
Electrical wiring and connection instructions
Procedurepp. 197-198
Inlet and outlet mechanical connections
Procedurepp. 199-200
Gas ballast operation and adjustment
Orderingpp. 201-202
List of accessories and spare parts
Procedurepp. 203-206
Cleaning and preventive maintenance procedures
Procedurepp. 207-208
Procedure for replacing tip seals
Servicespp. 217-218
Services requiring factory return
Procedurepp. 219-220
Troubleshooting guide and remedies
Specpp. 221-222
Serial connector pin allocation
Specpp. 223-226
Communication window description and protocol
pp. 227-230
Vacuum Products Division contact details
p. 189table, 17 rows
p. 187table, 28 rows
p. 190table, 9 rows
p. 195table, 9 rows
p. 216table, 11 rows
p. 224table, 19 rows
p. 203table, 11 rows
p. 201table, 5 rows
p. 207table, 4 rows
Table 1 IDP-4 Technical Specifications
Model
IDP-4 Dry Scroll Pump
Interface dimensions
H=181 mm x W=139 mm x L= 288 mm (7.1X5.5X11.3”)standard pump
H=237 mm x W=139 mm x L= 288 mm (VPI Valve)
H=237 mm x W=139 mm x L= 338 mm (with all accessories)
Peak pumping speed
(ISO 21360-1: 2020)
(ISO 21360-2: 2020)
65 L/min, (4 m3/h, 2.35 cfm) at full speed setting
Includes average peak pumping speed for both N2 and He without inlet valve configuration
Media
No corrosive, explosive or particulate forming gases
Ultimate Pressure*
(ISO 21360-1: 2020)
(ISO 21360-2: 2020)
1.8 +/- 0.2 x 10-1 Torr (2.4 +/- 0.27 x 10-1 mbar) at 3300 rpm (default setting)
Leak Rate
<1 x 10-6 sccs helium
Maximum recommended continuous inlet pressure
1.0 atmosphere (0 psig)
Maximum inlet pressure at nominal voltage
1.0 atmosphere (0 psig)
Maximum outlet pressure***
0.45 bar (6.5 psig)
Inlet connection
NW16
Exhaust connection
NW16
Gas ballast
Female 1/8" National Pipe Thread (adapter provided)
Ambient operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Ambient Relative Humidity
5-95%; non-condensing
Storage temperature
–20 °C to 60 °C (–4 °F to 140 °F)
Motor rating:
EN 60034-1-2:2007
EN 60034-30
(GB 18613-2020)
0.16 HP (0.12Kw)
Operating voltages**
Single phase
100-127VAC 50/60Hz
200-240 50/60Hz
Motor protection
Thermal protection/over current protection/fuse
* Ultimate Pressure; ** Operating voltages; *** Maximum outlet pressure
Technical Information
Раздел
Страница
Description of the IDP-4 Dry Scroll Pump
188
Technical Specifications
189
IDP-4 Dry Scroll Pump Outline Drawing
191
Performance Curves
193
Electrical Connections
195
Grounding Instructions
195
Mechanical Connections
197
Gas Ballast
199
Accessories and Spare Parts
201
Optional Accessories
201
Optional Inlet Valve Kit
202
Installation
204
Cleaning and Preventive Maintenance
205
External cleaning
205
Internal cleaning as part of a Preventive Maintenance plan
Pump only: 7.7kg (17 lbs)
Shipping weight: Approximately 9.8 kg (22 lbs) with accessories
Sound Pressure Levels (EN ISO 2151:2008) (ISO 4871:1996) (ISO 11201:2010)
50 to 55 +/- 2.5 dba (min to max RPM setting) with default configuration (gas ballast closed)
Fuse type
5A slow blown 250V 5X20 mm
Installation
Indoor use, Equipment Class 1, Overvoltage Category II, Pollution Degree 2
Altitude
2000 m (6562 ft)
Emissions and Immunity
Electromagnetic Compatibility 2014/30/EU:2014
EN 61326-1: (2013) as a Class A device
EN 61326-1: (2013) as a Class A device
EN 61000-3-2:2019 Class A
EN 61000-3-3:2014/A2:2022 Class A
EN 61000-6-2:2020
Safety
Machinery Directive 2006/42/EC: 2006
EN 1012-2:1996+A1: 2010
EN ISO 12100:2012
Low Voltage Directive 2006/95/EC: 2007
EC 61010-1 Ed. 3.1 b:2018
CSA certified for US and Canada
CE, ROHS
* If the pump is new or has been exposed to atmosphere for an extended period of time, it is possible that water can be present which can affect the pump’s ability to achieve ultimate pressure. To remove water from the pump and system, activate the gas ballast using the procedure in the gas ballast paragraph on page 199. Ultimate pressure will vary for different configuration and RPM setting. ** Mains supply voltage fluctuations shall not exceed ±10% of the nominal voltage. For operation in Japan, the pump will function at 100VAC, but may offer reduced peak pumping speed at maximum load conditions. For operation in Japan at high inlet pressures and high pumping loads, use of 200VAC is recommended. *** For customers with outlet pressure might experience different sound quality and slower pumping speed.
Table 2 Standard IDP-4 Power Cord Options
Country
Power Cord Specification
Part Number
Europe
10 A / 220-230 VAC, 2.5 m
656494220
Denmark
10 A / 220-230 VAC, 2.5 m
656494225
Switzerland
10 A / 230 VAC, 2.5 m
656494235
UK/Ireland
13 A / 230 VAC, 2.5 m
656494250
India
10 A / 220-250 VAC, 2.5 m
656494245
Israel
10 A / 230 VAC, 2.5 m
656494230
Japan
12 A / 100 VAC, 2.3 m
656494240
North America
10 A / 230 VAC, with C13 2.5 m (NEMA 6-15)
656494255
North America
13 A / 125 VAC, 2.0 m
656458203
Table 7 Maintenance Intervals and Part Numbers
Service Operation
Interval
Parts Needed
Part Number
Description
Regular Maintenance
Gas Ballast Activation
See Table 5 for suggested intervals based on application
None
Vent pump to atmospheric pressure
None
Minor Maintenance: Tip Seal & Main O-ring replacement
IDP3TS
IDP-3, 4 Tip Seal Kit
Replace Exhaust filter element
Yearly, if exhaust silencer is installed.
REPLSLRFILTER2
FILTER ELEMENT, IDP3,4 EXHAUST
If-Required Component Replacement
Front Cowling and cooling fan
If damaged or fan not functioning
X3802-67300
IDP-4 Fan & Cowling Kit
Feet
If broken or worn
IDP3VIBISOKIT
IDP-3, 4 Vibration Isol. Feet Kit
Plastic exhaust Manifold
If cracked, broken, or leaking.
X3803-67005
IDP-3, 4 Std Exhaust mfld Kit
VPI Valve
If leaking or damaged
VPI16IDP24DC
Sub-Assy, VPI Valve-24VDC, IDP3, 4
Standard Exhaust Flange
If damaged
X3802-67120
IDP-4 Std Exhaust Flange Kit
Table 11 Window meanings (continued)
Win #
Read
Write
Type
Name
Meaning
Default (Factory Set)
Unit
225
Always
Always
L
Inlet valve control
Control inlet valve open or close command This function is disabled during the 10-second startup delay that occurs when power is supplied to the pump or the power switch is turned ON.
-
-
227
Always
Always
L
Gas ballast valve control
Control gas ballast open or close command
-
-
232
Always
Off
N
Rotational Frequency
Rotational Reading Hz
-
0.1Hz
233
Always
Off
N
Rotational Frequency
Rotational Reading RPM
-
RPM
234
Always
Off
N
Bus Voltage
It reads the Bus Voltage
-
Volt
236
Always
Off
N
Torque
Estimate Mechanical Torque
-
N-mm
300
Always
Off
N
Cycle time
It indicates the time of the last complete cycle power on to power off
-
Minutes
301
Always
Off
N
Cycle number
It indicates the number of cycles start/stop during all the pump life.
-
-
302
Always
Off
N
Pump life
It indicates the total hours of pump life. The motor is running.
-
Hours
303
Always
Off
N
Total Error Counts
Total errors counts for life.
-
-
319
Always
Always
A
Controller Part Number
It is the Part Number of the controller
-
-
320
Always
Always
A
Pump Part Number
It is the Part Number of the pump
-
-
321
Always
Always
A
Pump Special Model
It indicates the Part Number of special pumps
-
-
322
Always
Always
A
Pump Serial Number
It indicates the Serial Number of the pump
-
-
323
Always
Always
A
Controller Serial Number
It indicates the Serial Number of the controller
-
-
324
Always
Always
A
Pump Modification Level
It indicates the upgrading level of the pump
-
-
325
Always
Always
A
Controller Modification Level
It indicates the upgrading level of the controller
-
-
358
Always
Always
N
Pump life since last service
It indicates the days after the last resetting
-
Days
399
Always
Off
N
Controller life
It indicates the total hours of Controller life. The total time the controller is powered on.
-
Hours
Table 4
Parameter
Value
Leak Rate:
Body
< 1X10-9 atm cc/sec He
Seal
<1X10-9 atm cc/sec He
Closing time (after solenoid valve power loss)
25 ms
Closing burst
0.01 torr-liter
Materials:
Body
Aluminum (6061-T6)
Seal
Viton
Temperature Range:
Valve Body
0~100 °C
Solenoid
0~50 °C
Table 3 Accessories
Part Number
Description
IDP3GBKIT
Gas Ballast kit
VPI16IDP24DC
VPI Valve-24VDC, IDP-4
EXSLRIDP3
Exhaust Silencer Kit
IDP3GBKIT
Breather Vent and Adapter
X3802-68001
Serial communication cable kit
Table 5 Suggested maintenance based on duty level
Description
Light-Duty
Medium-Duty
Heavy-Duty
Intermittent use Pump is shut down between experiments.
Continuous low-pressure use. Ex. turbo backing Low gas load
Continuous high inlet pressure use. High gas load
Vent to atmosphere
Upon start up and preparation for the experiment, vent the inlet to atmosphere for 5 seconds once the pump has reached full speed. Ensure the exhaust is not restricted. 1x per month if the application permits.
Properly isolate any sensitive equipment prior to venting. Run the pump at full speed with the inlet fully open for 5 seconds. Ensure the exhaust is not restricted. 1x per year
Properly isolate any sensitive equipment prior to venting. Run the pump at full speed with the inlet fully open for 5 seconds. Ensure the exhaust is not restricted.
Gas Ballast Use
Upon start up and preparation for the experiment, run the pump with the inlet capped and the gas ballast open for 4 hours to dry out any water accumulated during a preceding idle period.
Continuous gas ballast use is recommended if the application permits.
Periodic use of the gas ballast is likely required. Continuous use of the gas ballast is recommended if pumping a steady load of water vapor.
Tip Seal Replacement
Perform a minor maintenance on the pump every 10,000 hours, or when the pump’s ultimate pressure cannot be reached with overnight gas ballast use.
Perform minor maintenance on the pump every 18 - 24 months. Ensure that performance degradation is not due to water vapor prior to completing maintenance.
Perform minor maintenance once per year.
Engineering Facts
11 facts · every claim linked to a page
Selection
The pump is only for indoor use in clean, dry environments and is not certified for outdoor operation.
Determines whether the pump can be specified for a given site and enclosure class.
Source
“The IDP-4 Dry Scroll pump is designed and certified for operation indoors (installation category II) in relatively clean, dry environments (pollution degree 2).”
Selection
The pump is not intrinsically safe and must never be used with corrosive, pyrophoric, particle-forming or flammable gas mixtures.
Rules out the pump for aggressive or hazardous process gases at the selection stage.
Source
“The IDP-4 pump is NOT intrinsically safe and should never be used with corrosive, pyrophoric, particulate-forming gases or gas mixtures in their flammable and/or combustible range.”
Installation
The power cord must be IEC-320 style rated at least 10 A.
Defines the minimum supply cord rating needed for a compliant installation.
Source
“Connect the pump to the power supply using an IEC-320 style power cord of at least 10 A capacity.”
Installation
Operating ambient must stay within +5 to +40 °C and 5–95% non-condensing humidity.
Sets the environmental envelope the installation must satisfy.
Source
“Temperature: +5 °C to +40 °C (41 °F to 104°F)”
Installation
The pump needs at least 20 cm clearance on all sides for ventilation, maintenance and switch access.
Dictates the physical layout and free space around the pump.
Source
“This pump requires a clear space of at least 20 cm (8 in.) on all sides for ventilation, maintenance access and easy access to the power switch.”
Installation
The power switch and cord connection must remain easily accessible for quick disconnection.
Affects placement so the pump can be de-energized quickly in an emergency.
Source
“it is recommended that the pump be positioned in a way that the power switch and power cord connection remain easily accessible to the user in order to disconnect power pump quickly if needed.”
Operation
Poor initial vacuum is usually adsorbed water vapor; gas ballast for ~30 min to ~24 h restores full performance.
Explains expected pump-down behavior and the remedy at commissioning.
Source
“it can typically take between ~30 minutes to ~24 hours of gas ballast activation to achieve the full vacuum performance.”
Operation
Gas ballast must not be used with hazardous materials or gases that must not mix with air.
Prevents unsafe venting of process gases to atmosphere.
Source
“Do not use gas ballast if using potentially hazardous materials or those that should not be mixed with air.”
Operation
Blocking cooling vents can overheat the pump; surface above 65 °C is potentially damaging.
Defines the overheating threshold and the need for unobstructed airflow.
Source
“A pump surface temperature in excess of 65 °C (150 °F) is potentially damaging.”
Maintenance
Wait for the pump to fully stop and cool to room temperature before servicing or disconnecting.
Protects personnel from sharp edges and hot surfaces during service.
Source
“Before servicing the pump or before any mounting or disconnecting of the pump from the system, wait for the pump to come to a complete stop and cool down to room temperature.”
Maintenance
Equipment heavier than 20 kg must be moved with a suitable lifting device.
Sets the manual-handling limit for transport and installation.
Source
“Any equipment heavier than 20 kg should be transported using a suitable lifting device.”