Introduces consistent sample quality assessment and complete workflow solution
Config.pp. 4-5
Lists instrument models and options for different throughput needs
Specpp. 6-7
Describes quality metrics and automated electrophoresis analysis applications
Specp. 8
Covers oligonucleotide purity analysis workflow and system capabilities
Specp. 9
Describes protein analysis with the ProteoAnalyzer system
Servicesp. 10
Explains protection plans and services for sample QC instruments
Orderingpp. 11-12
Lists kits and reagents for automated electrophoresis systems
p. 4table, 10 rows
p. 10table, 7 rows
Instrument Options for a Variety of Nucleic Acid and Protein Applications
TapeStation Systems
Fragment Analyzer Systems
Femto Pulse System
ProteoAnalyzer System
ZAG System
DNA applications
RNA applications
FFPE RNA
IVT RNA
Total prokaryotic and eukaryotic RNA
Small RNA
MicroRNA
mRNA
Plant RNA
Protein applications
На странице отмечены галочки (), но их принадлежность к конкретным ячейкам по извлечённому тексту однозначно не восстанавливается; в таблице оставлены пустые ячейки.
Agilent CrossLab services for automated electrophoresis instruments
Fragment Analyzer System
Femto Pulse System
ProteoAnalyzer System
ZAG DNA Analyzer System
Oligo Pro II System
4150 and 4200 TapeStation Systems
IE Preferred/RTA
Onsite
Onsite
Onsite
Repair Type
Extended Warranty
CrossLab Service Plans
Preventive Maintenance
Compliance (IQ/OQ)
Enhanced Extended Warranty
Onsite
Onsite
IE = Instrument Exchange; RTA = Return to Agilent
Engineering Facts
12 facts · every claim linked to a page
Selection
The portfolio covers ultra-low to ultra-high throughput, so instrument choice should be matched to the lab's sample capacity.
Throughput class determines which instrument model fits the lab's workload.
Source
“If your lab’s sample capacity is ultra-low, medium, or ultra-high, Agilent has the sample quality control and fragment analysis solution that fits your need.”
Selection
Oligo Pro II is the specialized option for ssDNA/ssRNA oligonucleotide purity work, not a general nucleic acid QC instrument.
Prevents selecting a general fragment analyzer for oligonucleotide purity applications.
Source
“It provides high-resolution separations and direct detection of both single-stranded DNA (ssDNA) and single-stranded RNA (ssRNA) oligonucleotides.”
Selection
Oligo Pro II throughput scales via 12, 24, or 96 capillary arrays, which must be chosen at selection.
Capillary array configuration defines the instrument's capacity and must be specified.
Source
“12, 24, or 96 capillary arrays provide for throughput scalability”
Selection
Oligo Pro II achieves n-1 resolution only through 60 nt, limiting its use for longer oligonucleotides.
Defines the application range and prevents over-expecting resolution beyond 60 nt.
Source
“n–1 resolution through 60 nt”
Performance
ProteoAnalyzer separates 12 samples in as little as 30 minutes, replacing manual SDS-PAGE steps.
Gives the throughput/time benchmark needed to justify replacing SDS-PAGE.
Source
“Able to separate 12 samples in as little as 30 minutes”
Operation
ProteoAnalyzer automates separation, capillary rejuvenation, and data processing, reducing manual intervention.
Automation level affects labor requirements and operating procedures.
Source
“Automated separation, capillary rejuvenation, and data processing”
Operation
TapeStation uses ready-to-use ScreenTape devices, minimizing hands-on time and simplifying operation.
Consumable format drives operator training and daily workflow design.
Source
“Ready-to-use consumables ensure simple operation with minimal hands-on time.”
Selection
Quality metrics (GQN, DIN, RINe, DV200, RQN, %cfDNA) are available only on certain systems; Oligo Pro II, ZAG, and ProteoAnalyzer do not offer them.
Prevents selecting an instrument that cannot report the required QC metric.
Source
“The Agilent Oligo Pro II, ZAG and ProteoAnalyzer systems do not offer quality metrics.”
Maintenance
CrossLab service plans include preventive maintenance, compliance IQ/OQ, and repair options for the instruments.
Service coverage must be planned at installation to protect uptime and compliance.
Source
“Maximize uptime, ensure instrument compliance, and control your service costs with Agilent CrossLab services for your automated electrophoresis instruments.”
Conformité
IQ/OQ compliance service is offered as part of CrossLab service plans.
Regulated labs need IQ/OQ documentation available for installation qualification.
Source
“Compliance (IQ/OQ)”
Safety
The portfolio is for research use only and must not be used for diagnostic procedures.
Restricts deployment to research settings and affects regulatory classification.
Source
“For Research Use Only. Not for use in diagnostic procedures.”
Selection
Application-specific kits and reagents are designed per instrument system, so consumables must match the chosen platform.
Consumable compatibility must be verified against the selected instrument.
Source
“Application-specific kits and reagents have been designed for each of the automated electrophoresis systems.”